BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 34842354)

  • 1. Quantitative analysis and degradation mechanisms of different protein degradation methods.
    Zhang T; Zhang D; Liu H; Chen K
    J Biomed Mater Res B Appl Biomater; 2022 May; 110(5):1034-1043. PubMed ID: 34842354
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates.
    Lal S; Hall RM; Tipper JL
    Acta Biomater; 2016 Sep; 42():420-428. PubMed ID: 27395827
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations.
    Bell J; Besong AA; Tipper JL; Ingham E; Wroblewski BM; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2000; 214(5):513-8. PubMed ID: 11109859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing.
    Brandt JM; Charron K; Zhao L; MacDonald SJ; Medley JB
    Proc Inst Mech Eng H; 2012 Jun; 226(6):427-40. PubMed ID: 22783759
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints.
    Bell J; Tipper JL; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2001; 215(2):259-63. PubMed ID: 11382086
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear Mechanism of Artificial Joint Failure Using Wear Debris Analysis.
    Zhang D; Liu H; Wang J; Sheng C; Li Z
    J Nanosci Nanotechnol; 2018 Oct; 18(10):6805-6814. PubMed ID: 29954497
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses.
    Maskiewicz VK; Williams PA; Prates SJ; Bowsher JG; Clarke IC
    J Biomed Mater Res B Appl Biomater; 2010 Aug; 94(2):429-440. PubMed ID: 20583304
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of analyzed lubricant volumes on the amount and characteristics of generated wear particles from three different types of polyethylene liner materials.
    Markhoff J; Zietz C; Fabry C; Fulda G; Bader R
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1299-1306. PubMed ID: 28636252
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.
    Davidson JA; Poggie RA; Mishra AK
    Biomed Mater Eng; 1994; 4(3):213-29. PubMed ID: 7950870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants.
    Schappo H; Gindri IM; Cubillos PO; Maru MM; Salmoria GV; Roesler CRM
    J Arthroplasty; 2018 Jan; 33(1):258-262. PubMed ID: 28844766
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.
    Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of wear, acetabular cup inclination angle, load and serum degradation on the friction of a large diameter metal-on-metal hip prosthesis.
    Saikko V
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():1-9. PubMed ID: 30784784
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The origin of submicron polyethylene wear debris in total hip arthroplasty.
    McKellop HA; Campbell P; Park SH; Schmalzried TP; Grigoris P; Amstutz HC; Sarmiento A
    Clin Orthop Relat Res; 1995 Feb; (311):3-20. PubMed ID: 7634588
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo.
    Richards L; Brown C; Stone MH; Fisher J; Ingham E; Tipper JL
    J Bone Joint Surg Br; 2008 Aug; 90(8):1106-13. PubMed ID: 18669972
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests.
    Besong AA; Tipper JL; Mathews BJ; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 1999; 213(2):155-8. PubMed ID: 10333687
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.
    Ingram JH; Stone M; Fisher J; Ingham E
    Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision.
    Hatton A; Nevelos JE; Nevelos AA; Banks RE; Fisher J; Ingham E
    Biomaterials; 2002 Aug; 23(16):3429-40. PubMed ID: 12099286
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of friction and lubrication of different hip prostheses.
    Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(1):49-57. PubMed ID: 10718050
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions.
    Wang A; Essner A; Stark C; Dumbleton JH
    Biomaterials; 1996 May; 17(9):865-71. PubMed ID: 8718931
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.
    Williams S; Tipper JL; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2003; 217(3):155-63. PubMed ID: 12807156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.