These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 34843119)

  • 1. Per-voxel constraints to minimize hot spots in linear energy transfer-guided robust optimization for base of skull head and neck cancer patients in IMPT.
    Feng H; Shan J; Anderson JD; Wong WW; Schild SE; Foote RL; Patrick CL; Tinnon KB; Fatyga M; Bues M; Patel SH; Liu W
    Med Phys; 2022 Jan; 49(1):632-647. PubMed ID: 34843119
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Robust Optimization for Intensity Modulated Proton Therapy to Redistribute High Linear Energy Transfer from Nearby Critical Organs to Tumors in Head and Neck Cancer.
    Liu C; Patel SH; Shan J; Schild SE; Vargas CE; Wong WW; Ding X; Bues M; Liu W
    Int J Radiat Oncol Biol Phys; 2020 May; 107(1):181-193. PubMed ID: 31987967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust optimization to reduce the impact of biological effect variation from physical uncertainties in intensity-modulated proton therapy.
    Bai X; Lim G; Grosshans D; Mohan R; Cao W
    Phys Med Biol; 2019 Jan; 64(2):025004. PubMed ID: 30523932
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Robust intensity-modulated proton therapy to reduce high linear energy transfer in organs at risk.
    An Y; Shan J; Patel SH; Wong W; Schild SE; Ding X; Bues M; Liu W
    Med Phys; 2017 Dec; 44(12):6138-6147. PubMed ID: 28976574
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of linear and nonlinear programming approaches for "worst case dose" and "minmax" robust optimization of intensity-modulated proton therapy dose distributions.
    Zaghian M; Cao W; Liu W; Kardar L; Randeniya S; Mohan R; Lim G
    J Appl Clin Med Phys; 2017 Mar; 18(2):15-25. PubMed ID: 28300378
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical Note: 4D robust optimization in small spot intensity-modulated proton therapy (IMPT) for distal esophageal carcinoma.
    Feng H; Shan J; Ashman JB; Rule WG; Bhangoo RS; Yu NY; Chiang J; Fatyga M; Wong WW; Schild SE; Sio TT; Liu W
    Med Phys; 2021 Aug; 48(8):4636-4647. PubMed ID: 34058026
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A biological effect-guided optimization approach using beam distal-edge avoidance for intensity-modulated proton therapy.
    Bai X; Lim G; Grosshans D; Mohan R; Cao W
    Med Phys; 2020 Sep; 47(9):3816-3825. PubMed ID: 32557747
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Multiple Beams on Plan Quality, Linear Energy Transfer Distribution, and Plan Robustness of Intensity Modulated Proton Therapy for Lung Cancer.
    Shang H; Pu Y; Chen Z; Wang X; Yuan C; Jin X; Liu C
    ACS Sens; 2021 Feb; 6(2):408-417. PubMed ID: 33125211
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Exploratory Investigation of Dose-Linear Energy Transfer (LET) Volume Histogram (DLVH) for Adverse Events Study in Intensity Modulated Proton Therapy (IMPT).
    Yang Y; Vargas CE; Bhangoo RS; Wong WW; Schild SE; Daniels TB; Keole SR; Rwigema JM; Glass JL; Shen J; DeWees TA; Liu T; Bues M; Fatyga M; Liu W
    Int J Radiat Oncol Biol Phys; 2021 Jul; 110(4):1189-1199. PubMed ID: 33621660
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Linear energy transfer-guided optimization in intensity modulated proton therapy: feasibility study and clinical potential.
    Giantsoudi D; Grassberger C; Craft D; Niemierko A; Trofimov A; Paganetti H
    Int J Radiat Oncol Biol Phys; 2013 Sep; 87(1):216-22. PubMed ID: 23790771
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linear energy transfer weighted beam orientation optimization for intensity-modulated proton therapy.
    Gu W; Ruan D; Zou W; Dong L; Sheng K
    Med Phys; 2021 Jan; 48(1):57-70. PubMed ID: 32542711
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Linear energy transfer incorporated intensity modulated proton therapy optimization.
    Cao W; Khabazian A; Yepes PP; Lim G; Poenisch F; Grosshans DR; Mohan R
    Phys Med Biol; 2017 Dec; 63(1):015013. PubMed ID: 29131808
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.
    Gu W; O'Connor D; Nguyen D; Yu VY; Ruan D; Dong L; Sheng K
    Med Phys; 2018 Apr; 45(4):1338-1350. PubMed ID: 29394454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers.
    Liu W; Frank SJ; Li X; Li Y; Park PC; Dong L; Ronald Zhu X; Mohan R
    Med Phys; 2013 May; 40(5):051711. PubMed ID: 23635259
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Introducing Proton Track-End Objectives in Intensity Modulated Proton Therapy Optimization to Reduce Linear Energy Transfer and Relative Biological Effectiveness in Critical Structures.
    Traneus E; Ödén J
    Int J Radiat Oncol Biol Phys; 2019 Mar; 103(3):747-757. PubMed ID: 30395906
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mixed integer programming with dose-volume constraints in intensity-modulated proton therapy.
    Zhang P; Fan N; Shan J; Schild SE; Bues M; Liu W
    J Appl Clin Med Phys; 2017 Sep; 18(5):29-35. PubMed ID: 28681976
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technical Note: Treatment planning system (TPS) approximations matter - comparing intensity-modulated proton therapy (IMPT) plan quality and robustness between a commercial and an in-house developed TPS for nonsmall cell lung cancer (NSCLC).
    Liu C; Yu NY; Shan J; Bhangoo RS; Daniels TB; Chiang JS; Ding X; Lara P; Patrick CL; Archuleta JP; DeWees T; Hu Y; Schild SE; Bues M; Sio TT; Liu W
    Med Phys; 2019 Nov; 46(11):4755-4762. PubMed ID: 31498885
    [TBL] [Abstract][Full Text] [Related]  

  • 18. PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization.
    Liu W; Frank SJ; Li X; Li Y; Zhu RX; Mohan R
    Med Phys; 2013 Feb; 40(2):021709. PubMed ID: 23387732
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reoptimization of Intensity Modulated Proton Therapy Plans Based on Linear Energy Transfer.
    Unkelbach J; Botas P; Giantsoudi D; Gorissen BL; Paganetti H
    Int J Radiat Oncol Biol Phys; 2016 Dec; 96(5):1097-1106. PubMed ID: 27869082
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.
    Liu W; Schild SE; Chang JY; Liao Z; Chang YH; Wen Z; Shen J; Stoker JB; Ding X; Hu Y; Sahoo N; Herman MG; Vargas C; Keole S; Wong W; Bues M
    Int J Radiat Oncol Biol Phys; 2016 May; 95(1):523-533. PubMed ID: 26725727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.