These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
110 related articles for article (PubMed ID: 34844272)
1. [Treatment Planning and Dose Verification for Combined Internal and External Radiotherapy (CIERT)]. Freudenberg R; Hartmann H; Andreeff M; Oehme L; Leichtner T; Fischer A; Paulus T; Krause M; Kotzerke J Nuklearmedizin; 2022 Feb; 61(1):49-57. PubMed ID: 34844272 [TBL] [Abstract][Full Text] [Related]
2. Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom. Schaeken B; Lelie S; Meijnders P; Van den Weyngaert D; Janssens H; Verellen D Med Phys; 2010 Dec; 37(12):6292-9. PubMed ID: 21302785 [TBL] [Abstract][Full Text] [Related]
3. A reusable OSL-film for 2D radiotherapy dosimetry. Wouter C; Dirk V; Paul L; Tom D Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456 [TBL] [Abstract][Full Text] [Related]
4. Radiochromic film calibration for low-energy seed brachytherapy dose measurement. Morrison H; Menon G; Sloboda RS Med Phys; 2014 Jul; 41(7):072101. PubMed ID: 24989396 [TBL] [Abstract][Full Text] [Related]
5. Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging. Xie WH; Su CT; Kao YJ; Chang TH; Chang YJ; Yao CH; Hsieh BY Med Phys; 2020 Mar; 47(3):1404-1410. PubMed ID: 31950500 [TBL] [Abstract][Full Text] [Related]
6. On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry. Lee C; Lee C; Lee JK Phys Med Biol; 2006 Nov; 51(21):N393-402. PubMed ID: 17047258 [TBL] [Abstract][Full Text] [Related]
7. Validation of a radiotherapy treatment planning system using an anthropomorphic phantom and MTS-N thermoluminescent detectors. Waligórski MP; Bilski P; Lesiak J; Byrski E; Rozwadowska-Bogusz B; Barańczyk R; Góra E; Ochab E; Olko P Radiat Prot Dosimetry; 2002; 101(1-4):477-80. PubMed ID: 12382795 [TBL] [Abstract][Full Text] [Related]
8. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060 [TBL] [Abstract][Full Text] [Related]
9. Monte Carlo simulations and phantom validation of low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope. Roa D; Leon S; Paucar O; Gonzales A; Schwarz B; Olguin E; Moskvin V; Alva-Sanchez M; Glassell M; Correa N; Moyses H; Shankar A; Hamrick B; Sarria GR; Li B; Tajima T; Necas A; Guzman C; Challco R; Montoya M; Meza Z; Zapata M; Gonzales A; Marquez F; Neira R; Vilca W; Mendez J; Hernandez J Phys Med; 2022 Feb; 94():24-34. PubMed ID: 34979431 [TBL] [Abstract][Full Text] [Related]
10. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification. McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854 [TBL] [Abstract][Full Text] [Related]
11. [Dosimetry of cell-monolayers in multiwell plates]. Freudenberg R; Andreeff M; Oehme L; Kotzerke J Nuklearmedizin; 2009; 48(3):120-6. PubMed ID: 19322501 [TBL] [Abstract][Full Text] [Related]
12. Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation. Chow JC; Jiang R; Leung MK J Appl Clin Med Phys; 2010 Nov; 12(1):3424. PubMed ID: 21330989 [TBL] [Abstract][Full Text] [Related]
13. Synchrotron stereotactic radiotherapy: dosimetry by Fricke gel and Monte Carlo simulations. Boudou C; Biston MC; Corde S; Adam JF; Ferrero C; Estève F; Elleaume H Phys Med Biol; 2004 Nov; 49(22):5135-44. PubMed ID: 15609563 [TBL] [Abstract][Full Text] [Related]
14. Reference dose determination in 60Co and high-energy radiotherapy photon beams by using Farmer-type cylindrical ionization chambers - an experimental investigation. Swanpalmer J Biomed Phys Eng Express; 2020 May; 6(4):045003. PubMed ID: 33444264 [TBL] [Abstract][Full Text] [Related]
15. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system. Austerlitz C; Campos CA Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456 [TBL] [Abstract][Full Text] [Related]
16. Acuros Öllers MC; Swinnen ACC; Verhaegen F Med Phys; 2020 Nov; 47(11):5829-5837. PubMed ID: 32970849 [TBL] [Abstract][Full Text] [Related]
17. The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning. Thomas TH; Devakumar D; Purnima S; Ravindran BP Phys Med Biol; 2009 Apr; 54(7):2067-77. PubMed ID: 19287087 [TBL] [Abstract][Full Text] [Related]
18. In-vivo dosimetry by diode semiconductors in combination with portal films during TBI: reporting a 5-year clinical experience. Mangili P; Fiorino C; Rosso A; Cattaneo GM; Parisi R; Villa E; Calandrino R Radiother Oncol; 1999 Sep; 52(3):269-76. PubMed ID: 10580875 [TBL] [Abstract][Full Text] [Related]
19. Technical Note: On the feasibility of performing dosimetry in target and organ at risk using polymer dosimetry gel and thermoluminescence detectors in an anthropomorphic, deformable, and multimodal pelvis phantom. Marot M; Elter A; Mann P; Schwahofer A; Lang C; Johnen W; Körber SA; Beuthien-Baumann B; Gillmann C Med Phys; 2021 Sep; 48(9):5501-5510. PubMed ID: 34260079 [TBL] [Abstract][Full Text] [Related]
20. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy. Schembri V; Heijmen BJ Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]