These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 34852277)

  • 21. Comparison of EEG and MEG in source localization of induced human gamma-band oscillations during visual stimulus.
    Mideksa KG; Hoogenboom N; Hellriegel H; Krause H; Schnitzler A; Deuschl G; Raethjen J; Heute U; Muthuraman M
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():8119-22. PubMed ID: 26738178
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Linear inverse source estimate of combined EEG and MEG data related to voluntary movements.
    Babiloni F; Carducci F; Cincotti F; Del Gratta C; Pizzella V; Romani GL; Rossini PM; Tecchio F; Babiloni C
    Hum Brain Mapp; 2001 Dec; 14(4):197-209. PubMed ID: 11668651
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Automatic and robust noise suppression in EEG and MEG: The SOUND algorithm.
    Mutanen TP; Metsomaa J; Liljander S; Ilmoniemi RJ
    Neuroimage; 2018 Feb; 166():135-151. PubMed ID: 29061529
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of the spatial resolution of source imaging techniques in high-density EEG and MEG.
    Hedrich T; Pellegrino G; Kobayashi E; Lina JM; Grova C
    Neuroimage; 2017 Aug; 157():531-544. PubMed ID: 28619655
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Exploring the limits of MEG spatial resolution with multipolar expansions.
    Wens V
    Neuroimage; 2023 Apr; 270():119953. PubMed ID: 36842521
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Sensitivity of magnetoencephalography as a diagnostic tool for epilepsy: a prospective study.
    Koster I; Ossenblok P; Brekelmans GJ; van der Linden I; Hillebrand A; Wijnen BF; Colon AJ
    Epileptic Disord; 2020 Jun; 22(3):264-272. PubMed ID: 32554358
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetoencephalography for localizing and characterizing the epileptic focus.
    Burgess RC
    Handb Clin Neurol; 2019; 160():203-214. PubMed ID: 31277848
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sensitivity of scalp 10-20 EEG and magnetoencephalography.
    Kakisaka Y; Alkawadri R; Wang ZI; Enatsu R; Mosher JC; Dubarry AS; Alexopoulos AV; Burgess RC
    Epileptic Disord; 2013 Mar; 15(1):27-31. PubMed ID: 23531601
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Anatomically constrained minimum variance beamforming applied to EEG.
    Murzin V; Fuchs A; Kelso JA
    Exp Brain Res; 2011 Oct; 214(4):515-28. PubMed ID: 21915671
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sensitivity of MEG and EEG to source orientation.
    Ahlfors SP; Han J; Belliveau JW; Hämäläinen MS
    Brain Topogr; 2010 Sep; 23(3):227-32. PubMed ID: 20640882
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Multimodal integration of EEG and MEG data: a simulation study with variable signal-to-noise ratio and number of sensors.
    Babiloni F; Babiloni C; Carducci F; Romani GL; Rossini PM; Angelone LM; Cincotti F
    Hum Brain Mapp; 2004 May; 22(1):52-62. PubMed ID: 15083526
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Localization of abnormal discharges causing insular epilepsy by magnetoencephalography.
    Park HM; Nakasato N; Tominaga T
    Tohoku J Exp Med; 2012 Mar; 226(3):207-11. PubMed ID: 22353789
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography.
    Boto E; Seedat ZA; Holmes N; Leggett J; Hill RM; Roberts G; Shah V; Fromhold TM; Mullinger KJ; Tierney TM; Barnes GR; Bowtell R; Brookes MJ
    Neuroimage; 2019 Nov; 201():116099. PubMed ID: 31419612
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Simultaneous SEEG-MEG-EEG recordings Overcome the SEEG limited spatial sampling.
    Gavaret M; Dubarry AS; Carron R; Bartolomei F; Trébuchon A; Bénar CG
    Epilepsy Res; 2016 Dec; 128():68-72. PubMed ID: 27816896
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Magnetoencephalographic yield of interictal spikes in temporal lobe epilepsy. Comparison with scalp EEG recordings.
    Lin YY; Shih YH; Hsieh JC; Yu HY; Yiu CH; Wong TT; Yeh TC; Kwan SY; Ho LT; Yen DJ; Wu ZA; Chang MS
    Neuroimage; 2003 Jul; 19(3):1115-26. PubMed ID: 12880837
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quantification of the benefit from integrating MEG and EEG data in minimum l2-norm estimation.
    Molins A; Stufflebeam SM; Brown EN; Hämäläinen MS
    Neuroimage; 2008 Sep; 42(3):1069-77. PubMed ID: 18602485
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Concordance between routine interictal magnetoencephalography and simultaneous scalp electroencephalography in a sample of patients with epilepsy.
    Kirsch HE; Mantle M; Nagarajan SS
    J Clin Neurophysiol; 2007 Jun; 24(3):215-31. PubMed ID: 17545825
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Anatomical constraints on source models for high-resolution EEG and MEG derived from MRI.
    Srinivasan R
    Technol Cancer Res Treat; 2006 Aug; 5(4):389-99. PubMed ID: 16866569
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Localisation of epileptic foci with electric, magnetic and combined electromagnetic models.
    Diekmann V; Becker W; Jürgens R; Grözinger B; Kleiser B; Richter HP; Wollinsky KH
    Electroencephalogr Clin Neurophysiol; 1998 Apr; 106(4):297-313. PubMed ID: 9741758
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Estimating scalp MEG from whole-head MEG measurements.
    Wang Y; Oertel U
    Brain Topogr; 2000; 12(3):219-27. PubMed ID: 10791684
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.