These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 34853986)

  • 21. Cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation: preliminary results using novel short-tip cryoballoon.
    Koektuerk B; Yorgun H; Koektuerk O; Turan CH; Aksoy MN; Turan RG; Gorr E; Bansmann PM; Hoppe C; Horlitz M
    J Interv Card Electrophysiol; 2016 Oct; 47(1):91-98. PubMed ID: 27189156
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The fourth cryoballoon generation with a shorter tip to facilitate real-time pulmonary vein potential recording: Feasibility and safety results.
    Straube F; Dorwarth U; Pongratz J; Brück B; Wankerl M; Hartl S; Hoffmann E
    J Cardiovasc Electrophysiol; 2019 Jun; 30(6):918-925. PubMed ID: 30907462
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of an additional right pulmonary vein on second-generation cryoballoon ablation for atrial fibrillation: a propensity matched score study.
    Takarada K; Ströker E; Abugattas JP; de Regibus V; Coutiño HE; Lusoc I; Capulzini L; Sieira J; Mugnai G; Salghetti F; Choudhury R; Iacopino S; de Asmundis C; Brugada P; Chierchia GB
    J Interv Card Electrophysiol; 2019 Jan; 54(1):1-8. PubMed ID: 29679186
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance).
    Aryana A; Kenigsberg DN; Kowalski M; Koo CH; Lim HW; O'Neill PG; Bowers MR; Hokanson RB; Ellenbogen KA;
    Heart Rhythm; 2017 Sep; 14(9):1319-1325. PubMed ID: 28625929
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ultra-high-resolution assessment of lesion extension after cryoballoon ablation for pulmonary vein isolation.
    Spera F; Narducci ML; Bencardino G; Perna F; Bisignani A; Pinnacchio G; Tondo C; Maggio R; Stabile G; Iacopino S; Tundo F; Ferraro A; De Simone A; Malacrida M; Pintus F; Crea F; Pelargonio G
    Front Cardiovasc Med; 2022; 9():985182. PubMed ID: 36439999
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation.
    Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA
    Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cryoballoon temperature parameters during cryoballoon ablation predict pulmonary vein reconnection and atrial fibrillation recurrence.
    Chahine Y; Afroze T; Bifulco SF; Macheret F; Abdulsalam N; Boyle PM; Akoum N
    J Interv Card Electrophysiol; 2023 Sep; 66(6):1367-1373. PubMed ID: 36418664
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment.
    Stabile G; Tondo C; Curnis A; Lunati M; Manfrin M; Molon G; Sciarra L; Mantica M; Iacopino S; Arena G; Landolina M; Arestia A; Verlato R
    Int J Cardiol; 2018 Dec; 272():118-122. PubMed ID: 30037629
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation.
    Cauti FM; Solimene F; Stabile G; Polselli M; Schillaci V; Arestia A; Shopova G; Iaia L; Giannitti CM; Rossi P; Bianchi S
    Pacing Clin Electrophysiol; 2021 Jan; 44(1):63-70. PubMed ID: 33210304
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Supplemental Radiofrequency Ablation After Acutely Unsuccessful Cryoballoon Pulmonary Vein Isolation is Associated With Increased Risk of Recurrent Atrial Fibrillation.
    Huang HD; Pietrasik G; Abid QU; Sharma PS; Krishnan K; Larsen TR; Trohman RG
    J Am Heart Assoc; 2020 May; 9(10):e015979. PubMed ID: 32394797
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance of two tools for pulmonary vein occlusion assessment with a novel navigation system in cryoballoon ablation procedure.
    Qiao Y; Zhao Z; Fu M; Cai X; Guo Y; Liu K; Guo J; Guo T; Niu G
    J Cardiovasc Electrophysiol; 2023 Jan; 34(1):16-23. PubMed ID: 36413675
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation.
    Bisignani A; Pannone L; Miraglia V; Sieira J; Iacopino S; Bala G; Ströker E; Overeinder I; Almorad A; Gauthey A; Monaco C; Paparella G; Osório TG; Sorgente A; Jordaens L; Brugada P; Chierchia GB; Asmundis C
    Pacing Clin Electrophysiol; 2022 May; 45(5):605-611. PubMed ID: 35352363
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Wieczorek M; Sassani K; Hoeltgen R
    J Interv Card Electrophysiol; 2021 Mar; 60(2):321-327. PubMed ID: 32621212
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Does Size Matter? Cryoballoon-Based Pulmonary Vein Isolation Using a Novel 25-mm Circular Mapping Catheter.
    Reissmann B; Schlüter M; Santoro F; Maurer T; Heeger CH; Lemes C; Fink T; Riedl J; Rillig A; Mathew S; Ouyang F; Kuck KH; Metzner A
    Circ J; 2018 Feb; 82(3):666-671. PubMed ID: 29279459
    [TBL] [Abstract][Full Text] [Related]  

  • 35. On the Quest for the Best Freeze: Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation.
    Ciconte G; Mugnai G; Sieira J; Velagić V; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Di Giovanni G; Baltogiannis G; Wauters K; Brugada P; de Asmundis C; Chierchia GB
    Circ Arrhythm Electrophysiol; 2015 Dec; 8(6):1359-65. PubMed ID: 26527624
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Validation of electrical ostial pulmonary vein isolation verified with a spiral inner lumen mapping catheter during second-generation cryoballoon ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Taniguchi H; Nakamura H; Hamaya R; Kusa S; Igarashi M; Hachiya H; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2017 Aug; 28(8):870-875. PubMed ID: 28497857
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of pulmonary vein reconnection patterns after multielectrode phased radiofrequency- and cryoballoon ablation of atrial fibrillation.
    Wieczorek M; Sassani K; Hoeltgen R
    BMC Cardiovasc Disord; 2020 Apr; 20(1):197. PubMed ID: 32326885
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry.
    Isonaga Y; Miyazaki S; Nitta J; Shirai Y; Inamura Y; Sagawa Y; Yamauchi Y; Sasaki T; Inaba O; Sasano T
    J Cardiovasc Electrophysiol; 2024 Jan; 35(1):198-205. PubMed ID: 38037864
    [TBL] [Abstract][Full Text] [Related]  

  • 39. First experience of POLARx™ versus Arctic Front Advance™: An early technology comparison.
    Creta A; Kanthasamy V; Schilling RJ; Rosengarten J; Khan F; Honarbakhsh S; Earley MJ; Hunter RJ; Finlay M
    J Cardiovasc Electrophysiol; 2021 Apr; 32(4):925-930. PubMed ID: 33590568
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Novel cryoballoon ablation system for pulmonary vein isolation: multicenter assessment of efficacy and safety-ANTARCTICA study.
    Heeger CH; Pott A; Sohns C; Riesinger L; Sommer P; Gasperetti A; Tondo C; Fassini G; Moser F; Lucas P; Weinmann K; Bohnen JE; Dahme T; Rillig A; Kuck KH; Wakili R; Metzner A; Tilz RR
    Europace; 2022 Dec; 24(12):1917-1925. PubMed ID: 36026521
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.