BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

45 related articles for article (PubMed ID: 34859313)

  • 1. Comparing fine needle biopsy techniques in solid pancreatic lesions: A prospective randomized study.
    Delgado-Cortés HM; Jáquez-Quintana JO; Gómez-Macías GS; Jiménez-Castillo RA; Barbosa-Quintana O; Salas-Valdez D; Reyna-Arechiga AI; Cab-Morales VA; Pelaez-Luna MC; Maldonado-Garza HJ
    Pancreatology; 2023 Nov; 23(7):836-842. PubMed ID: 37783603
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outcomes of Endoscopic Ultrasound-guided Fine Needle Biopsy Using a Novel Hydrostatic Stylet Tissue Acquisition Technique.
    Magahis PT; Westerveld D; Simons M; Carr-Locke DL; Sampath K; Sharaiha RZ; Mahadev S
    J Clin Gastroenterol; 2024 Apr; 58(4):407-414. PubMed ID: 37983811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Repeated endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic lesions after previous nondiagnostic or inconclusive sampling.
    Lisotti A; Cominardi A; Conti Bellocchi MC; Crinò SF; Larghi A; Facciorusso A; Arcidiacono PG; De Angelis C; Di Matteo FM; Fabbri C; Bertani H; Togliani T; Rizzatti G; Brancaccio M; Grillo A; Fantin A; Pezzoli A; D'Errico F; Amato A; Antonini F; Montale A; Pisani A; Forti E; Manno M; Carrara S; Petrone MC; Binda C; Zagari RM; Fusaroli P;
    Dig Endosc; 2024 May; 36(5):615-624. PubMed ID: 37712906
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study comparing histologic sample quantity and diagnostic accuracy.
    Karsenti D; Palazzo L; Perrot B; Zago J; Lemaistre AI; Cros J; Napoléon B
    Endoscopy; 2020 Sep; 52(9):747-753. PubMed ID: 32408361
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of the number of passes on diagnostic performance of EUS-fine needle biopsy of solid pancreatic masses: A systematic review and meta-analysis.
    Chalhoub JM; Hawa F; Grantham T; Lester J; Carpenter ES; Mendoza-Ladd A; Wani S; Machicado JD
    Gastrointest Endosc; 2024 Jun; ():. PubMed ID: 38852683
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endoscopic ultrasound-guided tissue acquisition beyond the pancreas.
    Manthopoulou E; Ramai D; Ioannou A; Gkolfakis P; Papanikolaou IS; Mangiavillano B; Triantafyllou K; Crinò SF; Facciorusso A
    Ann Gastroenterol; 2023; 36(3):257-266. PubMed ID: 37144012
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study.
    Fabbri C; Fornelli A; Fuccio L; Giovanelli S; Tarantino I; Antonini F; Liotta R; Frazzoni L; Gusella P; La Marca M; Barresi L; Macarri G; Traina M; De Biase D; Fiorino S; Jovine E; Larghi A; Cennamo V
    Endosc Ultrasound; 2019; 8(4):261-268. PubMed ID: 31115386
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of patients with biliary tract cancer, especially with intrahepatic cholangiocarcinoma.
    Yanaidani T; Hara K; Okuno N; Haba S; Kuwahara T; Kuraishi Y; Mizuno N; Ishikawa S; Yamada M; Yasuda T
    Clin Endosc; 2024 May; 57(3):384-392. PubMed ID: 38356172
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Slow-pull compared to suction technique for EUS-guided sampling of pancreatic solid lesions: a meta-analysis of randomized controlled trials.
    Capurso G; Archibugi L; Petrone MC; Arcidiacono PG
    Endosc Int Open; 2020 May; 8(5):E636-E643. PubMed ID: 32355882
    [No Abstract]   [Full Text] [Related]  

  • 10. Twenty versus 40 back-and-forth needle movements for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses: a prospective, crossover, randomized study.
    Hu X; Yu F; Cao T; Chen X; Nie H; Zhang Z; Wang F; Wang H; Fang J; Zhao Q
    Eur J Gastroenterol Hepatol; 2023 Aug; 35(8):836-842. PubMed ID: 37395235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endoscopic ultrasound-guided fine-needle biopsy with or without macroscopic on-site evaluation: a randomized controlled noninferiority trial.
    Mangiavillano B; Crinò SF; Facciorusso A; Di Matteo F; Barbera C; Larghi A; Rizzatti G; Carrara S; Spadaccini M; Auriemma F; Fabbri C; Binda C; Coluccio C; Marocchi G; Staiano T; Conti Bellocchi MC; Bernardoni L; Eusebi LH; Cirota GG; De Nucci G; Stigliano S; Manes G; Bonanno G; Ofosu A; Lamonaca L; Paduano D; Spatola F; Repici A
    Endoscopy; 2023 Feb; 55(2):129-137. PubMed ID: 36044915
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wet-suction versus slow-pull technique for endoscopic ultrasound-guided fine-needle biopsy: a multicenter, randomized, crossover trial.
    Crinò SF; Conti Bellocchi MC; Di Mitri R; Inzani F; Rimbaș M; Lisotti A; Manfredi G; Teoh AYB; Mangiavillano B; Sendino O; Bernardoni L; Manfrin E; Scimeca D; Unti E; Carlino A; Voiosu T; Mateescu RB; Fusaroli P; Lega S; Buscarini E; Pergola L; Chan SM; Lamonaca L; Ginès À; Fernández-Esparrach G; Facciorusso A; Larghi A
    Endoscopy; 2023 Mar; 55(3):225-234. PubMed ID: 35915956
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of suction techniques for EUS-guided tissue acquisition: Systematic review and network meta-analysis of randomized controlled trials.
    Giri S; Afzalpurkar S; Angadi S; Marikanty A; Sundaram S
    Endosc Int Open; 2023 Aug; 11(8):E703-E711. PubMed ID: 37564335
    [No Abstract]   [Full Text] [Related]  

  • 14. Recent Developments in the Field of Endoscopic Ultrasound for Diagnosis, Staging, and Treatment of Pancreatic Lesions.
    Poiraud M; Gkolfakis P; Arvanitakis M
    Cancers (Basel); 2023 Apr; 15(9):. PubMed ID: 37174012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fine Needle Biopsies of Solid Pancreatic Lesions: Tissue Acquisition Technique and Needle Design Do Not Impact Specimen Adequacy.
    Mendoza Ladd A; Casner N; Cherukuri SV; Garcia C; Padilla O; Dwivedi A; Hakim N
    Dig Dis Sci; 2022 Sep; 67(9):4549-4556. PubMed ID: 34859313
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dry suction versus wet suction technique of endoscopic ultrasound-guided fine-needle biopsy for diagnosis of solid pancreatic lesions: study protocol of a multicenter randomized controlled non-inferiority trial.
    Xu S; Wang J; Guo J; Xie F; Qiao W; Meng Y; Peng P; Hu H; Huang Y; Liu S; Qin M; Yao J; Li Y
    Trials; 2023 Dec; 24(1):805. PubMed ID: 38093381
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial.
    Di Mitri R; Mocciaro F; Antonini F; Scimeca D; Conte E; Bonaccorso A; Scibetta N; Unti E; Fornelli A; Giorgini S; Binda C; Macarri G; Larghi A; Fabbri C
    Dig Liver Dis; 2020 Feb; 52(2):178-184. PubMed ID: 31601535
    [TBL] [Abstract][Full Text] [Related]  

  • 18.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.