These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 34859698)

  • 21. Refractive prediction by various intraocular lens formulas using optical biometry and effect of ocular parameters on their accuracy.
    Ambade AK; Ambade RA; Raje DV
    Indian J Ophthalmol; 2022 Jan; 70(1):118-123. PubMed ID: 34937222
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Predictability of combined cataract surgery and trabeculectomy using Barrett Universal Ⅱ formula.
    Iijima K; Kamiya K; Iida Y; Kasahara M; Shoji N
    PLoS One; 2022; 17(6):e0270363. PubMed ID: 35737663
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of Posterior Corneal Asphericity on Refractive Error of SRK-T and Barrett Formulas for Lucidis IOL.
    Rabinovich M; Aramburu Del Boz AM; Al-Khatib D; Genestier JP; Bovet J
    Klin Monbl Augenheilkd; 2023 May; 240(5):683-688. PubMed ID: 34535025
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.
    Jeong J; Song H; Lee JK; Chuck RS; Kwon JW
    BMC Ophthalmol; 2017 May; 17(1):62. PubMed ID: 28464806
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anterior chamber depth, lens thickness and intraocular lens calculation formula accuracy: nine formulas comparison.
    Hipólito-Fernandes D; Luís ME; Serras-Pereira R; Gil P; Maduro V; Feijão J; Alves N
    Br J Ophthalmol; 2022 Mar; 106(3):349-355. PubMed ID: 33229347
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of newer Kane formula with Sanders Retzlaff Kraff/Theoretical and Barrett Universal II for calculation of intraocular lens power in Indian eyes.
    Paritekar P; Nayak A; Umesh Y; Sirivella I; Manoharan S; Khatib Z
    Indian J Ophthalmol; 2022 Apr; 70(4):1203-1207. PubMed ID: 35326016
    [TBL] [Abstract][Full Text] [Related]  

  • 27. EFFECT OF PHARMACOLOGICAL PUPIL DILATION ON INTRAOCULAR LENS POWER CALCULATION IN PATIENTS INDICATED FOR CATARACT SURGERY.
    Autrata D; Chrapek O; Drahorád S
    Cesk Slov Oftalmol; 2021; 77(4):192-200. PubMed ID: 34507495
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients.
    Chang P; Lin L; Li Z; Wang L; Huang J; Zhao YE
    Graefes Arch Clin Exp Ophthalmol; 2020 May; 258(5):1123-1131. PubMed ID: 32064543
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Refractive accuracy in eyes undergoing combined cataract extraction and Descemet membrane endothelial keratoplasty.
    Campbell JA; Ladas JG; Wang K; Woreta F; Srikumaran D
    Br J Ophthalmol; 2022 May; 106(5):623-627. PubMed ID: 33414244
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service.
    Darcy K; Gunn D; Tavassoli S; Sparrow J; Kane JX
    J Cataract Refract Surg; 2020 Jan; 46(1):2-7. PubMed ID: 32050225
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Accuracy of Intraocular Lens Calculation Formulas in Patients Undergoing Combined Phakic Intraocular Lens Removal and Cataract Surgery.
    Zhang J; Xia Z; Han X; Liu Z; Lin H; Qiu X; Zhang M; Ruan X; Chen X; Jin G; Gu X; Tan X; Luo L; Liu Y
    Am J Ophthalmol; 2022 Feb; 234():241-249. PubMed ID: 34624249
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Toric intraocular lens power calculation in cataract patients with keratoconus.
    Ton Y; Barrett GD; Kleinmann G; Levy A; Assia EI
    J Cataract Refract Surg; 2021 Nov; 47(11):1389-1397. PubMed ID: 33770295
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Nationwide multicentre comparison of preoperative biometry and predictability of cataract surgery in Japan.
    Kamiya K; Hayashi K; Tanabe M; Tabuchi H; Sato M; Gotoh N; Kojima T; Hatsusaka N;
    Br J Ophthalmol; 2022 Sep; 106(9):1227-1234. PubMed ID: 34108223
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens.
    Rocha-de-Lossada C; Colmenero-Reina E; Flikier D; Castro-Alonso FJ; Rodriguez-Raton A; García-Madrona JL; Peraza-Nieves J; Sánchez-González JM
    Eur J Ophthalmol; 2021 Nov; 31(6):2981-2988. PubMed ID: 33339479
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ratio of Axial Length to Corneal Radius in Japanese Patients and Accuracy of Intraocular Lens Power Calculation Based on Biometric Data.
    Omoto MK; Torii H; Hayashi K; Ayaki M; Tsubota K; Negishi K
    Am J Ophthalmol; 2020 Oct; 218():320-329. PubMed ID: 32209342
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery.
    Srivannaboon S; Chirapapaisan C
    Graefes Arch Clin Exp Ophthalmol; 2019 Dec; 257(12):2677-2682. PubMed ID: 31486917
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of the accuracy of 11 intraocular lens power calculation formulas.
    Carmona-González D; Castillo-Gómez A; Palomino-Bautista C; Romero-Domínguez M; Gutiérrez-Moreno MÁ
    Eur J Ophthalmol; 2021 Sep; 31(5):2370-2376. PubMed ID: 33054421
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Refractive predictability using two optical biometers and refraction types for intraocular lens power calculation in cataract surgery.
    Cheng H; Li J; Cheng B; Wu M
    Int Ophthalmol; 2020 Jul; 40(7):1849-1856. PubMed ID: 32297050
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intraocular lens power calculation for plus and minus lenses in high myopia using partial coherence interferometry.
    Fuest M; Plange N; Kuerten D; Schellhase H; Mazinani BAE; Walter P; Kohnen S; Widder RA; Roessler G
    Int Ophthalmol; 2021 May; 41(5):1585-1592. PubMed ID: 33521894
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use of fellow eye data in the calculation of intraocular lens power for the second eye.
    Olsen T
    Ophthalmology; 2011 Sep; 118(9):1710-5. PubMed ID: 21723613
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.