148 related articles for article (PubMed ID: 34862774)
1. [Design of Scalable Model of Cochlear Scala Tympani].
Wang Z; Li J; Wu Y; Guo J; Han F; Wang X
Zhongguo Yi Liao Qi Xie Za Zhi; 2021 Nov; 45(6):622-627. PubMed ID: 34862774
[TBL] [Abstract][Full Text] [Related]
2. Impact of Scala Tympani Geometry on Insertion Forces during Implantation.
Hrncirik F; Roberts IV; Swords C; Christopher PJ; Chhabu A; Gee AH; Bance ML
Biosensors (Basel); 2022 Nov; 12(11):. PubMed ID: 36354508
[TBL] [Abstract][Full Text] [Related]
3. Optimal path generation in scala tympani and path planning for robotic cochlear implant of perimodiolar electrode.
Wang Z; Li J; Wu Y; Zhu R; Wang B; Zhao K
Proc Inst Mech Eng H; 2020 Jun; 234(6):578-589. PubMed ID: 32186227
[TBL] [Abstract][Full Text] [Related]
4. Growing human-scale scala tympani-like
Aregueta Robles UA; Bartlett-Tomasetig F; Poole-Warren LA
Biofabrication; 2023 May; 15(3):. PubMed ID: 37094574
[TBL] [Abstract][Full Text] [Related]
5. Morphometric Analysis and Linear Measurements of the Scala Tympani and Implications in Cochlear Implant Electrodes.
Fujiwara RJT; Ishiyama G; Lopez IA; Ishiyama A
Otol Neurotol; 2023 Jun; 44(5):e343-e349. PubMed ID: 36893208
[TBL] [Abstract][Full Text] [Related]
6. Anatomically and mechanically accurate scala tympani model for electrode insertion studies.
Starovoyt A; Shaheen E; Putzeys T; Kerckhofs G; Politis C; Wouters J; Verhaert N
Hear Res; 2023 Mar; 430():108707. PubMed ID: 36773540
[TBL] [Abstract][Full Text] [Related]
7. Fabrication of human anatomy-based scala tympani models with a hydrophilic coating for cochlear implant insertion experiments.
Aebischer P; Caversaccio M; Wimmer W
Hear Res; 2021 May; 404():108205. PubMed ID: 33618163
[TBL] [Abstract][Full Text] [Related]
8. Temporal bone characterization and cochlear implant feasibility in the common marmoset (Callithrix jacchus).
Johnson LA; Della Santina CC; Wang X
Hear Res; 2012 Aug; 290(1-2):37-44. PubMed ID: 22583919
[TBL] [Abstract][Full Text] [Related]
9. Multichannel cochlear implantation in the scala vestibuli.
Lin K; Marrinan MS; Waltzman SB; Roland JT
Otol Neurotol; 2006 Aug; 27(5):634-8. PubMed ID: 16788421
[TBL] [Abstract][Full Text] [Related]
10. Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.
Kiefer J; Weber A; Pfennigdorff T; von Ilberg C
ORL J Otorhinolaryngol Relat Spec; 2000; 62(5):251-6. PubMed ID: 10965260
[TBL] [Abstract][Full Text] [Related]
11. Inroads toward robot-assisted cochlear implant surgery using steerable electrode arrays.
Zhang J; Wei W; Ding J; Roland JT; Manolidis S; Simaan N
Otol Neurotol; 2010 Oct; 31(8):1199-206. PubMed ID: 20864880
[TBL] [Abstract][Full Text] [Related]
12. In-Vitro Study of Speed and Alignment Angle in Cochlear Implant Electrode Array Insertions.
Aebischer P; Mantokoudis G; Weder S; Anschuetz L; Caversaccio M; Wimmer W
IEEE Trans Biomed Eng; 2022 Jan; 69(1):129-137. PubMed ID: 34110987
[TBL] [Abstract][Full Text] [Related]
13. Experimental Validation of a Three-Dimensional Heat Transfer Model Within the Scala Tympani With Application to Magnetic Cochlear Implant Surgery.
Esmailie F; Francoeur M; Ameel T
IEEE Trans Biomed Eng; 2021 Sep; 68(9):2821-2832. PubMed ID: 33523803
[TBL] [Abstract][Full Text] [Related]
14. Cochlear implantation: Predicting the scala tympani volume of the pediatric recipients.
Salamah M; Abdelsamad Y; Alahmadi A; Alsanosi A
Int J Pediatr Otorhinolaryngol; 2023 Feb; 165():111432. PubMed ID: 36640697
[TBL] [Abstract][Full Text] [Related]
15. [Applied anatomy of scala tympani inlet related to cochlear implantation].
Zou T; Guo M; Zhang H; Shu F; Xie N
Nan Fang Yi Ke Da Xue Xue Bao; 2012 Jun; 32(6):904-7. PubMed ID: 22699082
[TBL] [Abstract][Full Text] [Related]
16. Preservation of auditory brainstem response thresholds after cochleostomy and titanium microactuator implantation in the lateral wall of cat scala tympani.
Lesinski SG; Prewitt J; Bray V; Aravamudhan R; Bermeo Blanco OA; Farmer-Fedor BL; Ward JA
Otol Neurotol; 2014 Apr; 35(4):730-8. PubMed ID: 24622027
[TBL] [Abstract][Full Text] [Related]
17. Assessing Cochlear Implant Insertion Angle From an Intraoperative X-ray Using a Rotating 3D Helical Scala Tympani Model.
Giardina CK; Canfarotta MW; Thompson NJ; Fitzpatrick DC; Hodge SE; Baker J; O'Connell BP
Otol Neurotol; 2020 Jul; 41(6):e686-e694. PubMed ID: 32569244
[TBL] [Abstract][Full Text] [Related]
18. The Use of Clinically Measurable Cochlear Parameters in Cochlear Implant Surgery as Indicators for Size, Shape, and Orientation of the Scala Tympani.
Schurzig D; Timm ME; Majdani O; Lenarz T; Rau TS
Ear Hear; 2021; 42(4):1034-1041. PubMed ID: 33480625
[TBL] [Abstract][Full Text] [Related]
19. Comparative Impacts of Scala Vestibuli Versus Scala Tympani Cochlear Implantation on Auditory Performances and Programming Parameters in Partially Ossified Cochleae.
Trudel M; Côté M; Philippon D; Simonyan D; Villemure-Poliquin N; Bussières R
Otol Neurotol; 2018 Jul; 39(6):700-706. PubMed ID: 29702527
[TBL] [Abstract][Full Text] [Related]
20. Scala vestibuli cochlear implant supported by 3D modeling of the inner ear.
Holzmeister C; Andrianakis A; Kiss P; Moser U; Graupp M
Wien Klin Wochenschr; 2022 Mar; 134(5-6):243-248. PubMed ID: 34477971
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]