These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 34863589)

  • 1. Simulation, Implementation and Measurement of Defined Sound Fields for Blood-Brain Barrier Opening in Rats.
    Grudzenski S; Heger S; de Jonge A; Schipp J; Dumont E; Larrat B; Schad L; Platten M; Fatar M
    Ultrasound Med Biol; 2022 Mar; 48(3):422-436. PubMed ID: 34863589
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcranial blood-brain barrier opening in Alzheimer's disease patients using a portable focused ultrasound system with real-time 2-D cavitation mapping.
    Bae S; Liu K; Pouliopoulos AN; Ji R; Jiménez-Gambín S; Yousefian O; Kline-Schoder AR; Batts AJ; Tsitsos FN; Kokossis D; Mintz A; Honig LS; Konofagou EE
    Theranostics; 2024; 14(11):4519-4535. PubMed ID: 39113808
    [No Abstract]   [Full Text] [Related]  

  • 3. A Clinical System for Non-invasive Blood-Brain Barrier Opening Using a Neuronavigation-Guided Single-Element Focused Ultrasound Transducer.
    Pouliopoulos AN; Wu SY; Burgess MT; Karakatsani ME; Kamimura HAS; Konofagou EE
    Ultrasound Med Biol; 2020 Jan; 46(1):73-89. PubMed ID: 31668690
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Focused ultrasound-mediated blood-brain barrier opening is safe and feasible with moderately hypofractionated radiotherapy for brainstem diffuse midline glioma.
    Tazhibi M; McQuillan N; Wei HJ; Gallitto M; Bendau E; Webster Carrion A; Berg X; Kokossis D; Zhang X; Zhang Z; Jan CI; Mintz A; Gartrell RD; Syed HR; Fonseca A; Pavisic J; Szalontay L; Konofagou EE; Zacharoulis S; Wu CC
    J Transl Med; 2024 Mar; 22(1):320. PubMed ID: 38555449
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Affordable and Easy-to-Use Focused Ultrasound Device for Noninvasive and High Precision Drug Delivery to the Mouse Brain.
    Hu Z; Chen S; Yang Y; Gong Y; Chen H
    IEEE Trans Biomed Eng; 2022 Sep; 69(9):2723-2732. PubMed ID: 35157574
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound.
    Yang FY; Lee PY
    Int J Nanomedicine; 2012; 7():2573-82. PubMed ID: 22679368
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo.
    Samiotaki G; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Nov; 60(11):2257-65. PubMed ID: 24158283
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Localized Blood-Brain Barrier Opening in Ovine Model Using Image-Guided Transcranial Focused Ultrasound.
    Yoon K; Lee W; Chen E; Lee JE; Croce P; Cammalleri A; Foley L; Tsao AL; Yoo SS
    Ultrasound Med Biol; 2019 Sep; 45(9):2391-2404. PubMed ID: 31217090
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of focused ultrasound on locoregional drug delivery to the brain: Potential implications for brain tumor therapy.
    Uribe Cardenas R; Laramee M; Ray I; Dahmane N; Souweidane M; Martin B
    J Control Release; 2023 Oct; 362():755-763. PubMed ID: 37659767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of Hologram-Assisted Bilateral Blood-Brain Barrier Opening in Non-Human Primates.
    Jimenez-Gambin S; Bae S; Ji R; Tsitsos F; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Oct; 71(10):1172-1185. PubMed ID: 39196737
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: a short-term study.
    Baseri B; Choi JJ; Tung YS; Konofagou EE
    Ultrasound Med Biol; 2010 Sep; 36(9):1445-59. PubMed ID: 20800172
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monitoring of acoustic cavitation in microbubble-presented focused ultrasound exposure using gradient-echo MRI.
    Wu CH; Liu HL; Ho CT; Hsu PH; Fan CH; Yeh CK; Kang ST; Chen WS; Wang FN; Peng HH
    J Magn Reson Imaging; 2020 Jan; 51(1):311-318. PubMed ID: 31125166
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Contrast-enhanced ultrasound imaging for the detection of focused ultrasound-induced blood-brain barrier opening.
    Fan CH; Lin WH; Ting CY; Chai WY; Yen TC; Liu HL; Yeh CK
    Theranostics; 2014; 4(10):1014-25. PubMed ID: 25161701
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Natural aging and Alzheimer's disease pathology increase susceptibility to focused ultrasound-induced blood-brain barrier opening.
    Noel RL; Batts AJ; Ji R; Pouliopoulos AN; Bae S; Kline-Schoder AR; Konofagou EE
    Sci Rep; 2023 Apr; 13(1):6757. PubMed ID: 37185578
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Submicron-bubble-enhanced focused ultrasound for blood-brain barrier disruption and improved CNS drug delivery.
    Fan CH; Liu HL; Ting CY; Lee YH; Huang CY; Ma YJ; Wei KC; Yen TC; Yeh CK
    PLoS One; 2014; 9(5):e96327. PubMed ID: 24788566
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safe long-term repeated disruption of the blood-brain barrier using an implantable ultrasound device: a multiparametric study in a primate model.
    Horodyckid C; Canney M; Vignot A; Boisgard R; Drier A; Huberfeld G; François C; Prigent A; Santin MD; Adam C; Willer JC; Lafon C; Chapelon JY; Carpentier A
    J Neurosurg; 2017 Apr; 126(4):1351-1361. PubMed ID: 27285538
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic-resonance imaging for kinetic analysis of permeability changes during focused ultrasound-induced blood-brain barrier opening and brain drug delivery.
    Chai WY; Chu PC; Tsai MY; Lin YC; Wang JJ; Wei KC; Wai YY; Liu HL
    J Control Release; 2014 Oct; 192():1-9. PubMed ID: 24969355
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Guiding and monitoring focused ultrasound mediated blood-brain barrier opening in rats using power Doppler imaging and passive acoustic mapping.
    Singh A; Kusunose J; Phipps MA; Wang F; Chen LM; Caskey CF
    Sci Rep; 2022 Aug; 12(1):14758. PubMed ID: 36042266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.
    Tsai CH; Zhang JW; Liao YY; Liu HL
    Phys Med Biol; 2016 Apr; 61(7):2926-46. PubMed ID: 26988240
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Focused ultrasound-mediated noninvasive blood-brain barrier modulation: preclinical examination of efficacy and safety in various sonication parameters.
    Shin J; Kong C; Cho JS; Lee J; Koh CS; Yoon MS; Na YC; Chang WS; Chang JW
    Neurosurg Focus; 2018 Feb; 44(2):E15. PubMed ID: 29385915
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.