2. Single-center prospective study examining use of the Wattson temporary pacing guidewire for transcatheter aortic valve replacement. Hensey M; Sathananthan J; Alkhodair A; Landes U; Wood DA; Daniels D; Webb JG Catheter Cardiovasc Interv; 2020 Oct; 96(4):968-971. PubMed ID: 32150334 [TBL] [Abstract][Full Text] [Related]
3. Rapid pacing using the 0.035-in. Retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty. Hilling-Smith R; Cockburn J; Dooley M; Parker J; Newton A; Hill A; Trivedi U; de Belder A; Hildick-Smith D Catheter Cardiovasc Interv; 2017 Mar; 89(4):783-786. PubMed ID: 27726292 [TBL] [Abstract][Full Text] [Related]
4. Insights in a restricted temporary pacemaker strategy in a lean transcatheter aortic valve implantation program. Hokken TW; de Ronde M; Wolff Q; Schermers T; Ooms JF; van Wiechen MP; Kardys I; Daemen J; de Jaegere PP; Van Mieghem NM Catheter Cardiovasc Interv; 2022 Mar; 99(4):1197-1205. PubMed ID: 34837467 [TBL] [Abstract][Full Text] [Related]
5. [Left ventricular guidewire pacing during transcatheter aortic valve replacement]. Song GY; Liu XM; Teng SY; Luo T; Wang MY; Wang YB; Zhou Z; Niu GN; Qian J; Wu YJ Zhonghua Xin Xue Guan Bing Za Zhi; 2021 May; 49(5):461-466. PubMed ID: 34034379 [No Abstract] [Full Text] [Related]
6. Active fixation lead temporary pacing in patients with right bundle block undergoing transcatheter aortic valve implantation. Seder-Colomina E; Maille B; Klein V; Tovmassian L; Biermé C; Jaussaud N; Morera P; Porto A; Polo J; Cuisset T; Deharo P Arch Cardiovasc Dis; 2023 May; 116(5):291-293. PubMed ID: 36931923 [No Abstract] [Full Text] [Related]
7. Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement. Faurie B; Souteyrand G; Staat P; Godin M; Caussin C; Van Belle E; Mangin L; Meyer P; Dumonteil N; Abdellaoui M; Monségu J; Durand-Zaleski I; Lefèvre T; JACC Cardiovasc Interv; 2019 Dec; 12(24):2449-2459. PubMed ID: 31857014 [TBL] [Abstract][Full Text] [Related]
8. Guidewire-driven Left Ventricular Pacing During Transcatheter Aortic Valve Implantation. Díaz de la Llera LS; Cubero Gómez JM; Casquero Domínguez S; Fernández Quero M; Villa Gil-Ortega M; Guisado Rasco A Rev Esp Cardiol (Engl Ed); 2018 Oct; 71(10):869-871. PubMed ID: 28941981 [No Abstract] [Full Text] [Related]
9. The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion. Al-Azzam F; Greason KL; Krittanawong C; Williamson EE; McLeod CJ; King KS; Mathew V J Thorac Cardiovasc Surg; 2017 May; 153(5):1056-1062.e1. PubMed ID: 28073567 [TBL] [Abstract][Full Text] [Related]
10. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience. Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074 [TBL] [Abstract][Full Text] [Related]
11. Rapid ventricular pacing during transcatheter valve procedures using an internal device and programmer: A demonstration of feasibility. Jones BM; Jobanputra Y; Krishnaswamy A; Mick S; Bhargava M; Wilkoff BL; Kapadia SR Catheter Cardiovasc Interv; 2020 Apr; 95(5):1042-1048. PubMed ID: 31429191 [TBL] [Abstract][Full Text] [Related]
12. Left ventricular guidewire pacing for transcatheter aortic valve implantation. Guérios EE; Wenaweser P; Meier B Catheter Cardiovasc Interv; 2013 Dec; 82(7):E919-21. PubMed ID: 22581741 [TBL] [Abstract][Full Text] [Related]
13. Reducing cardiac tamponade caused by temporary pacemaker perforation in transcatheter aortic valve replacement. Feldt K; Dalén M; Meduri CU; Kastengren M; Bager J; Hörnsten J; Omar A; Rück A; Saleh N; Linder R; Settergren M Int J Cardiol; 2023 Apr; 377():26-32. PubMed ID: 36640966 [TBL] [Abstract][Full Text] [Related]
15. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience. Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846 [TBL] [Abstract][Full Text] [Related]
16. A pressure wire for rapid pacing, valve implantation and continuous haemodynamic monitoring during transcatheter aortic valve implantation procedures. Rodés-Cabau J; Ibrahim R; De Larochellière R; Ben Ali W; Paradis JM; Robichaud S; Dorval JF; Mohammadi S; Dumont E; Kalavrouziotis D; Mesnier J; Panagides V; Picard-Deland M; Lalancette S; Pelletier-Beaumont E EuroIntervention; 2022 Jul; 18(4):e345-e348. PubMed ID: 35588013 [No Abstract] [Full Text] [Related]
17. Pacing Over the Guidewire in Cardiac Structural Intervention: A Practical Guide. May A; Collins N; Jackson N; Fitzgerald J; Boyle A; Bhagwandeen R Heart Lung Circ; 2020 Nov; 29(11):e265-e268. PubMed ID: 32718903 [TBL] [Abstract][Full Text] [Related]
18. Rapid pacing using the left ventricular guidewire: Reviving an old technique to simplify BAV and TAVI procedures. Faurie B; Abdellaoui M; Wautot F; Staat P; Champagnac D; Wintzer-Wehekind J; Vanzetto G; Bertrand B; Monségu J Catheter Cardiovasc Interv; 2016 Nov; 88(6):988-993. PubMed ID: 27510946 [TBL] [Abstract][Full Text] [Related]
19. Safety and Efficacy of TAVR With a Pressure Sensor and Pacing Guidewire: SAFE-TAVI Trial. Regueiro A; Alperi A; Vilalta V; Asmarats L; Baz JA; Nombela-Franco L; Calabuig A; Muñoz-García A; Sabaté M; Moris C; Picard-Deland M; Pelletier-Beaumont E; Rodés-Cabau J JACC Cardiovasc Interv; 2023 Dec; 16(24):3016-3023. PubMed ID: 37902144 [TBL] [Abstract][Full Text] [Related]
20. Short term clinical outcomes and analysis of risk factors for pacemaker implantation: a single center experience of self-expandable TAVI valves. Chow SCY; Wong RHL; Cheung GSH; Lee APW; Chui HKL; So KCY; Wu EB J Cardiothorac Surg; 2020 Jul; 15(1):200. PubMed ID: 32727521 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]