133 related articles for article (PubMed ID: 34876361)
21. Accuracy and variability of high-dose-rate prostate brachytherapy needle tip localization using live two-dimensional and sagittally reconstructed three-dimensional ultrasound.
Hrinivich WT; Hoover DA; Surry K; Edirisinghe C; Velker V; Bauman G; D'Souza D; Fenster A; Wong E
Brachytherapy; 2017; 16(5):1035-1043. PubMed ID: 28764882
[TBL] [Abstract][Full Text] [Related]
22. Automatic shape-based level set segmentation for needle tracking in 3-D TRUS-guided prostate brachytherapy.
Yan P; Cheeseborough JC; Chao KS
Ultrasound Med Biol; 2012 Sep; 38(9):1626-36. PubMed ID: 22763006
[TBL] [Abstract][Full Text] [Related]
23. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results.
Kirisits C; Lang S; Dimopoulos J; Berger D; Georg D; Pötter R
Int J Radiat Oncol Biol Phys; 2006 Jun; 65(2):624-30. PubMed ID: 16690444
[TBL] [Abstract][Full Text] [Related]
24. Long term experience with 3D image guided brachytherapy and clinical outcome in cervical cancer patients.
Ribeiro I; Janssen H; De Brabandere M; Nulens A; De Bal D; Vergote I; Van Limbergen E
Radiother Oncol; 2016 Sep; 120(3):447-454. PubMed ID: 27157510
[TBL] [Abstract][Full Text] [Related]
25. A novel ultrasound probe calibration method for multimodal image guidance of needle placement in cervical cancer brachytherapy.
Pu G; Jiang S; Yang Z; Hu Y; Liu Z
Phys Med; 2022 Aug; 100():81-89. PubMed ID: 35759943
[TBL] [Abstract][Full Text] [Related]
26. Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.
Han DY; Safigholi H; Soliman A; Ravi A; Leung E; Scanderbeg DJ; Liu Z; Owrangi A; Song WY
Int J Radiat Oncol Biol Phys; 2016 Oct; 96(2):440-448. PubMed ID: 27598809
[TBL] [Abstract][Full Text] [Related]
27. Characterization of combined intracavitary/interstitial brachytherapy including oblique needles in locally advanced cervix cancer.
Serban M; Fokdal L; Nielsen SK; Hokland SB; Hansen AT; Spejlborg H; Rylander S; Petric P; Lindegaard JC; Tanderup K
Brachytherapy; 2021; 20(4):796-806. PubMed ID: 33994344
[TBL] [Abstract][Full Text] [Related]
28. Feasibility of transrectal ultrasonography for assessment of cervical cancer.
Schmid MP; Pötter R; Brader P; Kratochwil A; Goldner G; Kirchheiner K; Sturdza A; Kirisits C
Strahlenther Onkol; 2013 Feb; 189(2):123-8. PubMed ID: 23255091
[TBL] [Abstract][Full Text] [Related]
29. Clinical feasibility of combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer employing MRI with a tandem/ring applicator in situ and virtual preplanning of the interstitial component.
Fokdal L; Tanderup K; Hokland SB; Røhl L; Pedersen EM; Nielsen SK; Paludan M; Lindegaard JC
Radiother Oncol; 2013 Apr; 107(1):63-8. PubMed ID: 23452917
[TBL] [Abstract][Full Text] [Related]
30. Computed Tomography-Guided Optimization of Needle Insertion for Combined Intracavitary/Interstitial Brachytherapy With Utrecht Applicator in Locally Advanced Cervical Cancer.
Tambas M; Tavli B; Bilici N; Dizman A; Sertel H; Fayda M
Pract Radiat Oncol; 2021; 11(4):272-281. PubMed ID: 33556579
[TBL] [Abstract][Full Text] [Related]
31. Label-driven magnetic resonance imaging (MRI)-transrectal ultrasound (TRUS) registration using weakly supervised learning for MRI-guided prostate radiotherapy.
Zeng Q; Fu Y; Tian Z; Lei Y; Zhang Y; Wang T; Mao H; Liu T; Curran WJ; Jani AB; Patel P; Yang X
Phys Med Biol; 2020 Jun; 65(13):135002. PubMed ID: 32330922
[TBL] [Abstract][Full Text] [Related]
32. MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer.
Lindegaard JC; Tanderup K; Nielsen SK; Haack S; Gelineck J
Int J Radiat Oncol Biol Phys; 2008 Jul; 71(3):756-64. PubMed ID: 18191335
[TBL] [Abstract][Full Text] [Related]
33. Adaptive image guided brachytherapy for cervical cancer: a combined MRI-/CT-planning technique with MRI only at first fraction.
Nesvacil N; Pötter R; Sturdza A; Hegazy N; Federico M; Kirisits C
Radiother Oncol; 2013 Apr; 107(1):75-81. PubMed ID: 23068712
[TBL] [Abstract][Full Text] [Related]
34. The addition of interstitial needles to intracavitary applicators in the treatment of locally advanced cervical cancer: Why is this important and how to implement in low- and middle-income countries?
Lombe D; Crook J; Bachand F; Moore J; Hamm J; Rose T; Anderson D; Batchelar D
Brachytherapy; 2020; 19(3):316-322. PubMed ID: 32229073
[TBL] [Abstract][Full Text] [Related]
35. A novel multi-modality imaging phantom for validating interstitial needle guidance for high dose rate gynecological brachytherapy.
Eckroate B; Ayala-Peacock D; Venkataraman R; Campelo S; Chino J; Stephens SJ; Kim Y; Meltsner S; Raffi J; Craciunescu O
J Appl Clin Med Phys; 2023 Oct; 24(10):e14075. PubMed ID: 37335537
[TBL] [Abstract][Full Text] [Related]
36. Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.
Mayer A; Zholkover A; Portnoy O; Raviv G; Konen E; Symon Z
Int J Comput Assist Radiol Surg; 2016 Jun; 11(6):1015-23. PubMed ID: 27017500
[TBL] [Abstract][Full Text] [Related]
37. Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact.
van Heerden LE; van Kesteren Z; Gurney-Champion OJ; Houweling AC; Koedooder K; Rasch CRN; Pieters BR; Bel A
Int J Radiat Oncol Biol Phys; 2017 Nov; 99(3):710-718. PubMed ID: 29280466
[TBL] [Abstract][Full Text] [Related]
38. Proof of principle: Applicator-guided stereotactic IMRT boost in combination with 3D MRI-based brachytherapy in locally advanced cervical cancer.
Assenholt MS; Vestergaard A; Kallehauge JF; Mohamed S; Nielsen SK; Petersen JB; Fokdal L; Lindegaard JC; Tanderup K
Brachytherapy; 2014; 13(4):361-8. PubMed ID: 24656732
[TBL] [Abstract][Full Text] [Related]
39. Deep learning-based digitization of prostate brachytherapy needles in ultrasound images.
Andersén C; Rydén T; Thunberg P; Lagerlöf JH
Med Phys; 2020 Dec; 47(12):6414-6420. PubMed ID: 33012023
[TBL] [Abstract][Full Text] [Related]
40. Clinical feasibility of interstitial brachytherapy using a "hybrid" applicator combining uterine tandem and interstitial metal needles based on CT for locally advanced cervical cancer.
Liu ZS; Guo J; Lin X; Wang HY; Qiu L; Ren XJ; Li YF; Zhang BY; Wang TJ
Brachytherapy; 2016; 15(5):562-9. PubMed ID: 27474180
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]