BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 34876361)

  • 21. Accuracy and variability of high-dose-rate prostate brachytherapy needle tip localization using live two-dimensional and sagittally reconstructed three-dimensional ultrasound.
    Hrinivich WT; Hoover DA; Surry K; Edirisinghe C; Velker V; Bauman G; D'Souza D; Fenster A; Wong E
    Brachytherapy; 2017; 16(5):1035-1043. PubMed ID: 28764882
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Automatic shape-based level set segmentation for needle tracking in 3-D TRUS-guided prostate brachytherapy.
    Yan P; Cheeseborough JC; Chao KS
    Ultrasound Med Biol; 2012 Sep; 38(9):1626-36. PubMed ID: 22763006
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results.
    Kirisits C; Lang S; Dimopoulos J; Berger D; Georg D; Pötter R
    Int J Radiat Oncol Biol Phys; 2006 Jun; 65(2):624-30. PubMed ID: 16690444
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long term experience with 3D image guided brachytherapy and clinical outcome in cervical cancer patients.
    Ribeiro I; Janssen H; De Brabandere M; Nulens A; De Bal D; Vergote I; Van Limbergen E
    Radiother Oncol; 2016 Sep; 120(3):447-454. PubMed ID: 27157510
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A novel ultrasound probe calibration method for multimodal image guidance of needle placement in cervical cancer brachytherapy.
    Pu G; Jiang S; Yang Z; Hu Y; Liu Z
    Phys Med; 2022 Aug; 100():81-89. PubMed ID: 35759943
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.
    Han DY; Safigholi H; Soliman A; Ravi A; Leung E; Scanderbeg DJ; Liu Z; Owrangi A; Song WY
    Int J Radiat Oncol Biol Phys; 2016 Oct; 96(2):440-448. PubMed ID: 27598809
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Characterization of combined intracavitary/interstitial brachytherapy including oblique needles in locally advanced cervix cancer.
    Serban M; Fokdal L; Nielsen SK; Hokland SB; Hansen AT; Spejlborg H; Rylander S; Petric P; Lindegaard JC; Tanderup K
    Brachytherapy; 2021; 20(4):796-806. PubMed ID: 33994344
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Feasibility of transrectal ultrasonography for assessment of cervical cancer.
    Schmid MP; Pötter R; Brader P; Kratochwil A; Goldner G; Kirchheiner K; Sturdza A; Kirisits C
    Strahlenther Onkol; 2013 Feb; 189(2):123-8. PubMed ID: 23255091
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical feasibility of combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer employing MRI with a tandem/ring applicator in situ and virtual preplanning of the interstitial component.
    Fokdal L; Tanderup K; Hokland SB; Røhl L; Pedersen EM; Nielsen SK; Paludan M; Lindegaard JC
    Radiother Oncol; 2013 Apr; 107(1):63-8. PubMed ID: 23452917
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Computed Tomography-Guided Optimization of Needle Insertion for Combined Intracavitary/Interstitial Brachytherapy With Utrecht Applicator in Locally Advanced Cervical Cancer.
    Tambas M; Tavli B; Bilici N; Dizman A; Sertel H; Fayda M
    Pract Radiat Oncol; 2021; 11(4):272-281. PubMed ID: 33556579
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Label-driven magnetic resonance imaging (MRI)-transrectal ultrasound (TRUS) registration using weakly supervised learning for MRI-guided prostate radiotherapy.
    Zeng Q; Fu Y; Tian Z; Lei Y; Zhang Y; Wang T; Mao H; Liu T; Curran WJ; Jani AB; Patel P; Yang X
    Phys Med Biol; 2020 Jun; 65(13):135002. PubMed ID: 32330922
    [TBL] [Abstract][Full Text] [Related]  

  • 32. MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer.
    Lindegaard JC; Tanderup K; Nielsen SK; Haack S; Gelineck J
    Int J Radiat Oncol Biol Phys; 2008 Jul; 71(3):756-64. PubMed ID: 18191335
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Adaptive image guided brachytherapy for cervical cancer: a combined MRI-/CT-planning technique with MRI only at first fraction.
    Nesvacil N; Pötter R; Sturdza A; Hegazy N; Federico M; Kirisits C
    Radiother Oncol; 2013 Apr; 107(1):75-81. PubMed ID: 23068712
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The addition of interstitial needles to intracavitary applicators in the treatment of locally advanced cervical cancer: Why is this important and how to implement in low- and middle-income countries?
    Lombe D; Crook J; Bachand F; Moore J; Hamm J; Rose T; Anderson D; Batchelar D
    Brachytherapy; 2020; 19(3):316-322. PubMed ID: 32229073
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A novel multi-modality imaging phantom for validating interstitial needle guidance for high dose rate gynecological brachytherapy.
    Eckroate B; Ayala-Peacock D; Venkataraman R; Campelo S; Chino J; Stephens SJ; Kim Y; Meltsner S; Raffi J; Craciunescu O
    J Appl Clin Med Phys; 2023 Oct; 24(10):e14075. PubMed ID: 37335537
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Deformable registration of trans-rectal ultrasound (TRUS) and magnetic resonance imaging (MRI) for focal prostate brachytherapy.
    Mayer A; Zholkover A; Portnoy O; Raviv G; Konen E; Symon Z
    Int J Comput Assist Radiol Surg; 2016 Jun; 11(6):1015-23. PubMed ID: 27017500
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact.
    van Heerden LE; van Kesteren Z; Gurney-Champion OJ; Houweling AC; Koedooder K; Rasch CRN; Pieters BR; Bel A
    Int J Radiat Oncol Biol Phys; 2017 Nov; 99(3):710-718. PubMed ID: 29280466
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Proof of principle: Applicator-guided stereotactic IMRT boost in combination with 3D MRI-based brachytherapy in locally advanced cervical cancer.
    Assenholt MS; Vestergaard A; Kallehauge JF; Mohamed S; Nielsen SK; Petersen JB; Fokdal L; Lindegaard JC; Tanderup K
    Brachytherapy; 2014; 13(4):361-8. PubMed ID: 24656732
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Deep learning-based digitization of prostate brachytherapy needles in ultrasound images.
    Andersén C; Rydén T; Thunberg P; Lagerlöf JH
    Med Phys; 2020 Dec; 47(12):6414-6420. PubMed ID: 33012023
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical feasibility of interstitial brachytherapy using a "hybrid" applicator combining uterine tandem and interstitial metal needles based on CT for locally advanced cervical cancer.
    Liu ZS; Guo J; Lin X; Wang HY; Qiu L; Ren XJ; Li YF; Zhang BY; Wang TJ
    Brachytherapy; 2016; 15(5):562-9. PubMed ID: 27474180
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.