BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 34878612)

  • 1. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correction to: Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Aug; 36(4):1235-1236. PubMed ID: 34989950
    [No Abstract]   [Full Text] [Related]  

  • 4. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
    Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
    Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Are peristaltic pumps as reliable as syringe pumps for metabolic research? Assessment of accuracy, precision, and metabolic kinetics.
    Mohammed BS; Fields DA; Mittendorfer B; Coggan AR; Klein S
    Metabolism; 2004 Jul; 53(7):875-8. PubMed ID: 15254880
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel Pump Control Technology Accelerates Drug Delivery Onset in a Model of Pediatric Drug Infusion.
    Parker MJ; Lovich MA; Tsao AC; Deng H; Houle T; Peterfreund RA
    Anesth Analg; 2017 Apr; 124(4):1129-1134. PubMed ID: 28181934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.
    Parker MJ; Lovich MA; Tsao AC; Wei AE; Wakim MG; Maslov MY; Tsukada H; Peterfreund RA
    Anesthesiology; 2015 Mar; 122(3):647-58. PubMed ID: 25419684
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An in vitro evaluation of infusion methods using a syringe pump to improve noradrenaline administration.
    Genay S; Décaudin B; Scoccia S; Barthélémy C; Debaene B; Lebuffe G; Odou P
    Acta Anaesthesiol Scand; 2015 Feb; 59(2):197-204. PubMed ID: 25476454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Drug Infusion Systems: Technologies, Performance, and Pitfalls.
    Kim UR; Peterfreund RA; Lovich MA
    Anesth Analg; 2017 May; 124(5):1493-1505. PubMed ID: 28212219
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of syringe size on reliability and safety of low-flow infusions.
    Neal D; Lin JA
    Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluid delivery from infusion-pump syringes.
    Carl JL; Erstad BL; Murphy JE; Slack MK
    Am J Health Syst Pharm; 1995 Jul; 52(13):1428-32. PubMed ID: 7671041
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
    Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
    Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.