These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 34878612)

  • 41. The effect of syringe size on the performance of an infusion pump.
    Kim DW; Steward DJ
    Paediatr Anaesth; 1999; 9(4):335-7. PubMed ID: 10411770
    [TBL] [Abstract][Full Text] [Related]  

  • 42. An evaluation of intravenous infusion pumps and controllers.
    Runciman WB; Ilsley AH; Rutten AJ; Baker D; Fronsko RR
    Anaesth Intensive Care; 1987 May; 15(2):217-28. PubMed ID: 3605571
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Flow irregularities from syringe infusion pumps caused by syringe stiction.
    Peduzzi N; Batliner M; Grass B; Buehler PK; Schmid Daners M; Meboldt M; Weiss M
    Paediatr Anaesth; 2020 Aug; 30(8):885-891. PubMed ID: 32443169
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Miniaturized peristaltic rotary pump for non-continuous drug dosing
    Tamadon I; Simoni V; Iacovacci V; Vistoli F; Ricotti L; Menciassi A
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5522-5526. PubMed ID: 31947105
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The impact on drug mass flow rate of interrupting and resuming carrier fluid flow: an in vitro study on a very low dead-space volume infusion set.
    Lannoy D; Decaudin B; Simon N; Barthelemy C; Debaene B; Odou P
    Anesth Analg; 2012 Feb; 114(2):328-32. PubMed ID: 22025488
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A comparison between single and double-pump syringe changes of intravenous inotropic medications in children.
    Powell ML; Carnevale FA
    Dynamics; 2004; 15(4):10-4. PubMed ID: 15638352
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Central venous catheter infusions: a laboratory model shows large differences in drug delivery dynamics related to catheter dead volume.
    Lovich MA; Peterfreund GL; Sims NM; Peterfreund RA
    Crit Care Med; 2007 Dec; 35(12):2792-8. PubMed ID: 18074479
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [The Baxter AS 50 syringe pump: a comparison with propofol-specific syringe pumps].
    Terai T; Tanaka M; Suzuki N
    Masui; 2001 Jan; 50(1):80-2. PubMed ID: 11211760
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
    Weiss M; Gerber S; Füchslin RM; Neff TA
    Anaesthesia; 2004 Nov; 59(11):1133-7. PubMed ID: 15479325
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Syringe infusion pumps with dose error reduction systems.
    Health Devices; 2008 Feb; 37(2):33-51. PubMed ID: 18773865
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants.
    Capes DF; Dunster KR; Sunderland VB; McMillan D; Colditz PB; McDonald C
    Am J Health Syst Pharm; 1995 Aug; 52(15):1646-53. PubMed ID: 7583827
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Accuracy of intravenous infusion pumps in continuous renal replacement therapies.
    Jenkins R; Harrison H; Chen B; Arnold D; Funk J
    ASAIO J; 1992; 38(4):808-10. PubMed ID: 1450476
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Research on influence of different syringe types on quality control of syringe pump].
    Liu H; Huang H; Wang W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2014 Dec; 31(6):1316-8, 1324. PubMed ID: 25868251
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Evaluation of the venting principle to reduce start-up delays in syringe infusion pumps used for microinfusions.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M
    J Clin Monit Comput; 2024 Feb; 38(1):213-220. PubMed ID: 37610525
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Consequences of syringe size sensor malfunction in a modern infusion pump.
    Derrick JL; Ho AM; Cho AM
    Anaesth Intensive Care; 2003 Feb; 31(1):75-9. PubMed ID: 12635400
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A comparison of infusion devices at 1 ml/hr.
    Wood BR; Huddleston K; Kolm P
    Neonatal Intensive Care; 1993; 6(3):20-2. PubMed ID: 10148553
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Dosing errors in preterm neonates due to flow rate variability in multi-infusion syringe pump setups: An in vitro spectrophotometry study.
    Snijder RA; Egberts TC; Lucas P; Lemmers PM; van Bel F; Timmerman AM
    Eur J Pharm Sci; 2016 Oct; 93():56-63. PubMed ID: 27497614
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Flow variability and its physical causes in infusion technology: a systematic review of in vitro measurement and modeling studies.
    Snijder RA; Konings MK; Lucas P; Egberts TC; Timmerman AD
    Biomed Tech (Berl); 2015 Aug; 60(4):277-300. PubMed ID: 26352348
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Preparing Drugs for Infusion Via Syringe Pump: A Key Step to Ensure Homogeneous Concentration.
    Garrigue B; Dehu Y; Girault F; Figadère B; Leblanc K; Briole N; Capitani GA; Lagadec S; Laborne FX
    Crit Care Nurse; 2016 Aug; 36(4):36-44. PubMed ID: 27481800
    [TBL] [Abstract][Full Text] [Related]  