These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 34884153)

  • 1. Evaluation of Polytyramine Film and 6-Mercaptohexanol Self-Assembled Monolayers as the Immobilization Layers for a Capacitive DNA Sensor Chip: A Comparison.
    Mahadhy A; Mattiasson B; StåhlWernersson E; Hedström M
    Sensors (Basel); 2021 Dec; 21(23):. PubMed ID: 34884153
    [TBL] [Abstract][Full Text] [Related]  

  • 2. DNA sensor based on an Escherichia coli lac Z gene probe immobilization at self-assembled monolayers-modified gold electrodes.
    Loaiza OA; Campuzano S; Pedrero M; Pingarrón JM
    Talanta; 2007 Oct; 73(5):838-44. PubMed ID: 19073109
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of a capacitive affinity biosensor for sensitive and selective detection and quantification of DNA-A model study.
    Mahadhy A; Ståhl-Wernersson E; Mattiasson B; Hedström M
    Biotechnol Rep (Amst); 2014 Sep; 3():42-48. PubMed ID: 28626647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Structural Changes of Mercaptohexanol Self-Assembled Monolayers on Gold and Their Influence on Impedimetric Aptamer Sensors.
    Xu X; Makaraviciute A; Kumar S; Wen C; Sjödin M; Abdurakhmanov E; Danielson UH; Nyholm L; Zhang Z
    Anal Chem; 2019 Nov; 91(22):14697-14704. PubMed ID: 31650834
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A capacitive DNA sensor for sensitive detection of Escherichia coli O157:H7 in potable water based on the z3276 genetic marker: fabrication and analytical performance.
    Deshmukh R; Prusty AK; Roy U; Bhand S
    Analyst; 2020 Mar; 145(6):2267-2278. PubMed ID: 31996887
    [TBL] [Abstract][Full Text] [Related]  

  • 6. DNA microdevice for electrochemical detection of Escherichia coli 0157:H7 molecular markers.
    Berganza J; Olabarria G; García R; Verdoy D; Rebollo A; Arana S
    Biosens Bioelectron; 2007 Apr; 22(9-10):2132-7. PubMed ID: 17084071
    [TBL] [Abstract][Full Text] [Related]  

  • 7. DNA Immobilization and Hybridization Detection by the Intrinsic Molecular Charge Using Capacitive Field-Effect Sensors Modified with a Charged Weak Polyelectrolyte Layer.
    Bronder TS; Poghossian A; Scheja S; Wu C; Keusgen M; Mewes D; Schöning MJ
    ACS Appl Mater Interfaces; 2015 Sep; 7(36):20068-75. PubMed ID: 26327272
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrochemical genosensor for Klotho detection based on aliphatic and aromatic thiols self-assembled monolayers.
    Sánchez-Paniagua M; Palenzuela-Batista S; Manzanares-Palenzuela CL; López-Ruiz B
    Talanta; 2020 May; 212():120735. PubMed ID: 32113527
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new methodology for electrostatic immobilization of a non-labeled single strand DNA onto a self-assembled diazonium modified gold electrode and detection of its hybridization by differential pulse voltammetry.
    Mashhadizadeh MH; Talemi RP
    Talanta; 2013 Jan; 103():344-8. PubMed ID: 23200397
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gold nanoparticles modified electrode via a mercapto-diazoaminobenzene monolayer and its development in DNA electrochemical biosensor.
    Li F; Feng Y; Dong P; Tang B
    Biosens Bioelectron; 2010 May; 25(9):2084-8. PubMed ID: 20207131
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode.
    Labib M; Hedström M; Amin M; Mattiasson B
    Anal Chim Acta; 2010 Feb; 659(1-2):194-200. PubMed ID: 20103124
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasensitive DNA sensor based on gold nanoparticles/reduced graphene oxide/glassy carbon electrode.
    Benvidi A; Firouzabadi AD; Moshtaghiun SM; Mazloum-Ardakani M; Tezerjani MD
    Anal Biochem; 2015 Sep; 484():24-30. PubMed ID: 25988596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment.
    Yang J; Yang T; Feng Y; Jiao K
    Anal Biochem; 2007 Jun; 365(1):24-30. PubMed ID: 17420003
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface regeneration and reusability of label-free DNA biosensors based on weak polyelectrolyte-modified capacitive field-effect structures.
    Bronder TS; Poghossian A; Jessing MP; Keusgen M; Schöning MJ
    Biosens Bioelectron; 2019 Feb; 126():510-517. PubMed ID: 30476882
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of Electrochemical DNA Biosensor for Equine Hindgut Acidosis Detection.
    Davies J; Thomas C; Rizwan M; Gwenin C
    Sensors (Basel); 2021 Mar; 21(7):. PubMed ID: 33810389
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bioelectrochemical sensing based on single stranded deoxyribonucleic acid-carbon nanotubes covalently attached on gold electrodes.
    Santiago-Rodríguez L; Vargas-Barbosa NM; Sánchez-Pomales G; Cabrera CR
    J Nanosci Nanotechnol; 2009 Apr; 9(4):2450-5. PubMed ID: 19437989
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Redox-Active Monolayers Self-Assembled on Gold Electrodes-Effect of Their Structures on Electrochemical Parameters and DNA Sensing Ability.
    Malecka K; Menon S; Palla G; Kumar KG; Daniels M; Dehaen W; Radecka H; Radecki J
    Molecules; 2020 Jan; 25(3):. PubMed ID: 32019203
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Screening of self-assembled monolayer for aflatoxin B1 detection using immune-capacitive sensor.
    Gutierrez R AV; Hedström M; Mattiasson B
    Biotechnol Rep (Amst); 2015 Dec; 8():144-151. PubMed ID: 28352584
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Part I: Non-faradaic electrochemical impedance-based DNA biosensor for detecting phytopathogen - Ralstonia solanacearum.
    Patel R; Vinchurkar M; Mohin Shaikh A; Patkar R; Adami A; Giacomozzi F; Ramesh R; Pramanick B; Lorenzelli L; Shojaei Baghini M
    Bioelectrochemistry; 2023 Apr; 150():108370. PubMed ID: 36630871
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new immobilization procedure for development of an electrochemical immunosensor for parathyroid hormone detection based on gold electrodes modified with 6-mercaptohexanol and silane.
    Sayıklı Şimşek Ç; Nur Sonuç Karaboğa M; Sezgintürk MK
    Talanta; 2015 Nov; 144():210-8. PubMed ID: 26452812
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.