These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 3488556)

  • 1. Dependence of the coincidence aperture function of narrow BGO crystals on crystal shape and light encoding schemes.
    Thompson CJ; Roney JM; Lecomte R; Schmitt D; Lupton LR
    Phys Med Biol; 1986 May; 31(5):491-506. PubMed ID: 3488556
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A BGO detector unit for a stationary high resolution positron emission tomograph.
    Yamamoto S; Miura S; Iida H; Kanno I
    J Comput Assist Tomogr; 1986; 10(5):851-5. PubMed ID: 3489019
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of the angle of incidence on the sensitivity of gamma camera based PET.
    Vandenberghe S; D'Asseler Y; Kolthammer J; Van de Walle R; Lemahieu I; Dierckx RA
    Phys Med Biol; 2002 Jan; 47(2):289-303. PubMed ID: 11837618
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CeBr
    Dal Bello R; Magalhaes Martins P; Seco J
    Med Phys; 2018 Apr; 45(4):1622-1630. PubMed ID: 29411400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inter-crystal scatter in a dual layer, high resolution LSO-APD positron emission tomograph.
    Rafecas M; Böning G; Pichler BJ; Lorenz E; Schwaiger M; Ziegler SI
    Phys Med Biol; 2003 Apr; 48(7):821-48. PubMed ID: 12701889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT.
    Ito M; Lee JS; Park MJ; Sim KS; Hong SJ
    Phys Med Biol; 2010 Jul; 55(13):3827-41. PubMed ID: 20551503
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.
    Levin CS; Hoffman EJ
    Phys Med Biol; 1999 Mar; 44(3):781-99. PubMed ID: 10211810
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility study for positron emission mammography.
    Thompson CJ; Murthy K; Weinberg IN; Mako F
    Med Phys; 1994 Apr; 21(4):529-38. PubMed ID: 8058019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations.
    Hasegawa T; Yoshida E; Kobayashi A; Shibuya K; Nishikido F; Kobayashi T; Suga M; Yamaya T; Kitamura K; Maruyama K; Murayama H
    Phys Med Biol; 2007 Jan; 52(1):213-30. PubMed ID: 17183137
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wedge-shaped scintillation crystals for positron emission tomography.
    Schmitt D; Lecomte R; LeBel E
    J Nucl Med; 1986 Jan; 27(1):99-104. PubMed ID: 3484523
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method for accurate modelling of the crystal response function at a crystal sub-level applied to PET reconstruction.
    Stute S; Benoit D; Martineau A; Rehfeld NS; Buvat I
    Phys Med Biol; 2011 Feb; 56(3):793-809. PubMed ID: 21239844
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detector response restoration in image reconstruction of high resolution positron emission tomography.
    Liang Z
    IEEE Trans Med Imaging; 1994; 13(2):314-21. PubMed ID: 18218507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Monte Carlo simulation of Compton scattering in positron emission tomography.
    Logan J; Bernstein HJ
    J Comput Assist Tomogr; 1983 Apr; 7(2):316-20. PubMed ID: 6601120
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.
    Tai YC; Chatziioannou AF; Yang Y; Silverman RW; Meadors K; Siegel S; Newport DF; Stickel JR; Cherry SR
    Phys Med Biol; 2003 Jun; 48(11):1519-37. PubMed ID: 12817935
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wedge-shaped BGO scintillation crystal for positron emission tomography: concise communication.
    Cho ZH; Lee HS; Hong KS
    J Nucl Med; 1984 Aug; 25(8):901-4. PubMed ID: 6611391
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance characteristics of Positologica III: a whole-body positron emission tomograph.
    Senda M; Tamaki N; Yonekura Y; Tanada S; Murata K; Hayashi N; Fujita T; Saji H; Konishi J; Torizuka K
    J Comput Assist Tomogr; 1985; 9(5):940-6. PubMed ID: 3875640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simulation study of PET detector limitations using continuous crystals.
    Cabello J; Etxebeste A; Llosá G; Ziegler SI
    Phys Med Biol; 2015 May; 60(9):3673-94. PubMed ID: 25884464
    [TBL] [Abstract][Full Text] [Related]  

  • 20. PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.
    Thompson CJ; Moreno-Cantu J; Picard Y
    Phys Med Biol; 1992 Mar; 37(3):731-49. PubMed ID: 1565700
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.