These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 34890323)

  • 1. A Non-invasive Radial Arterial Compliance Measuring Method using Bio-Impedance.
    Tang X; Jankovic M; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():2330-2334. PubMed ID: 34890323
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-source Multi-frequency Bio-impedance Measurement Method for Localized Pulse Wave Monitoring.
    Ibrahim B; Talukder A; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3945-3948. PubMed ID: 33018863
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Bio-Impedance Sensor Placement Relative to the Arterial Sites for Capturing Hemodynamic Parameters.
    Ibrahim B; Mrugala D; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():6569-6573. PubMed ID: 31947347
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder.
    Ibrahim B; Jafari R
    Sci Rep; 2022 Jan; 12(1):319. PubMed ID: 35013376
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement.
    Wang TW; Syu JY; Chu HW; Sung YL; Chou L; Escott E; Escott O; Lin TT; Lin SF
    Biosensors (Basel); 2022 Feb; 12(3):. PubMed ID: 35323420
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time Signal-to-Noise Ratio Optimization of Bio-Impedance Signal for Cuffless Blood Pressure Monitoring.
    Passage B; Ibrahim B; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7480-7484. PubMed ID: 34892823
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.
    Weiss BM; Spahn DR; Rahmig H; Rohling R; Pasch T
    Br J Anaesth; 1996 Mar; 76(3):405-11. PubMed ID: 8785142
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of mean arterial pressure: comparison of the Vasotrac monitor with the finger differential oscillometric device.
    Jagomägi K; Raamat R; Talts J; Ragun U; Tähepõld P
    Physiol Res; 2010; 59(5):691-696. PubMed ID: 20406039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Beat-to-beat agreement of non-invasive finger artery and invasive radial artery blood pressure in hypertensive patients taking cardiovascular medication.
    Lindqvist A
    Clin Physiol; 1995 May; 15(3):219-29. PubMed ID: 7621644
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bio-Impedance Measurement Optimization for High-Resolution Carotid Pulse Sensing.
    Wang TW; Chu HW; Chou L; Sung YL; Shih YT; Hsu PC; Cheng HM; Lin SF
    Sensors (Basel); 2021 Feb; 21(5):. PubMed ID: 33668822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Peripheral vascular decoupling in porcine endotoxic shock.
    Hatib F; Jansen JR; Pinsky MR
    J Appl Physiol (1985); 2011 Sep; 111(3):853-60. PubMed ID: 21700890
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blood Pressure Estimation using a Single Channel Bio-Impedance Ring Sensor.
    Osman D; Jankovic M; Sel K; Pettigrew RI; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():4286-4290. PubMed ID: 36086457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.
    Langwieser N; Prechtl L; Meidert AS; Hapfelmeier A; Bradaric C; Ibrahim T; Laugwitz KL; Schmid RM; Wagner JY; Saugel B
    Clin Res Cardiol; 2015 Jun; 104(6):518-24. PubMed ID: 25618259
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.
    Sun J; Chen H; Zheng J; Mao B; Zhu S; Feng J
    J Clin Monit Comput; 2017 Dec; 31(6):1189-1195. PubMed ID: 28000041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impaired radial artery compliance in normotensive subjects with familial hypercholesterolemia.
    Giannattasio C; Mangoni AA; Failla M; Carugo S; Stella ML; Stefanoni P; Grassi G; Vergani C; Mancia G
    Atherosclerosis; 1996 Aug; 124(2):249-60. PubMed ID: 8830937
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulse Wave Modeling Using Bio-Impedance Simulation Platform Based on a 3D Time-Varying Circuit Model.
    Ibrahim B; Hall DA; Jafari R
    IEEE Trans Biomed Circuits Syst; 2021 Feb; 15(1):143-158. PubMed ID: 33577456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Accuracy of the CNAP® Device Compared with Invasive Radial Artery Measurements for Providing Continuous Noninvasive Arterial Blood Pressure Readings at a Medical Intensive Care Unit: A Method-Comparison Study.
    Smolle KH; Schmid M; Prettenthaler H; Weger C
    Anesth Analg; 2015 Dec; 121(6):1508-16. PubMed ID: 26496367
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aortic valve replacement reduces valvuloarterial impedance but does not affect systemic arterial compliance in elderly men with degenerative calcific trileaflet aortic valve stenosis.
    Pagel PS; Schroeder AR; De Vry DJ; Hudetz JA
    J Cardiothorac Vasc Anesth; 2014 Dec; 28(6):1540-4. PubMed ID: 25267695
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Wrist-worn Respiration Monitoring Device using Bio-Impedance
    Sel K; Brown A; Jang H; Krumholz HM; Lu N; Jafari R
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3989-3993. PubMed ID: 33018874
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device.
    Saugel B; Meidert AS; Hapfelmeier A; Eyer F; Schmid RM; Huber W
    Br J Anaesth; 2013 Aug; 111(2):185-90. PubMed ID: 23491946
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.