These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 34891570)

  • 1. Mechanical Analysis of the Quadruple Butterfly Coil during Transcranial Magnetic Stimulation and Magnetic Resonance Imaging
    Afuwape OF; Kiarie WM; Bentil SA; Jiles DC
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1504-1507. PubMed ID: 34891570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Simulation study of force and temperature field during transcranial magnetic stimulation application working with magnetic resonance imaging simultaneously].
    Xu B; Lu M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2022 Aug; 39(4):685-693. PubMed ID: 36008332
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design of TMS coils with reduced Lorentz forces: application to concurrent TMS-fMRI.
    Cobos Sánchez C; Cabello MR; Olozábal ÁQ; Pantoja MF
    J Neural Eng; 2020 Feb; 17(1):016056. PubMed ID: 32049657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Coil Designs for Transcranial Magnetic Stimulation of a Pig Model.
    Afuwape OF; Runge J; Bentil SA; Jiles DC
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1535-1538. PubMed ID: 34891576
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Application and Progress of Real-time Interleaved Transcranial Magnetic Stimulation Functional Magnetic Resonance Imaging].
    Ma YQ; Xie RX; Zheng Z; Ma D; Wu M
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2020 Sep; 51(5):592-598. PubMed ID: 32975070
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom.
    Navarro de Lara LI; Golestanirad L; Makarov SN; Stockmann JP; Wald LL; Nummenmaa A
    Magn Reson Med; 2020 Aug; 84(2):1061-1075. PubMed ID: 31971632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A 3-axis coil design for multichannel TMS arrays.
    Navarro de Lara LI; Daneshzand M; Mascarenas A; Paulson D; Pratt K; Okada Y; Raij T; Makarov SN; Nummenmaa A
    Neuroimage; 2021 Jan; 224():117355. PubMed ID: 32916290
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.
    Deng ZD; Lisanby SH; Peterchev AV
    Brain Stimul; 2013 Jan; 6(1):1-13. PubMed ID: 22483681
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physiological observations validate finite element models for estimating subject-specific electric field distributions induced by transcranial magnetic stimulation of the human motor cortex.
    Opitz A; Legon W; Rowlands A; Bickel WK; Paulus W; Tyler WJ
    Neuroimage; 2013 Nov; 81():253-264. PubMed ID: 23644000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved SNR for combined TMS-fMRI: A support device for commercially available body array coil.
    Wang WT; Xu B; Butman JA
    J Neurosci Methods; 2017 Sep; 289():1-7. PubMed ID: 28673806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acoustic noise generated by TMS in typical environment and inside an MRI scanner.
    Nyrhinen MJ; Souza VH; Ilmoniemi RJ; Lin FH
    Brain Stimul; 2024; 17(2):184-193. PubMed ID: 38342363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design of transcranial magnetic stimulation coils with optimal trade-off between depth, focality, and energy.
    Gomez LJ; Goetz SM; Peterchev AV
    J Neural Eng; 2018 Aug; 15(4):046033. PubMed ID: 29855433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Behavioral and Functional Brain Activity Alterations Induced by TMS Coils with Different Spatial Distributions.
    Pell GS; Roth Y; Shachar H; Isserles M; Barnea-Ygael N; Zangen A
    eNeuro; 2023 Apr; 10(4):. PubMed ID: 36931728
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mapping the after-effects of theta burst stimulation on the human auditory cortex with functional imaging.
    Andoh J; Zatorre RJ
    J Vis Exp; 2012 Sep; (67):e3985. PubMed ID: 23007549
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A semi-automated pipeline for finite element modeling of electric field induced in nonhuman primates by transcranial magnetic stimulation.
    Goswami N; Shen M; Gomez LJ; Dannhauer M; Sommer MA; Peterchev AV
    J Neurosci Methods; 2024 Aug; 408():110176. PubMed ID: 38795980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Temporal and spatial profiles of evoked activity induced by magnetic stimulation using millimeter-sized coils in the mouse auditory cortex in vivo.
    Yoshikawa T; Higuchi H; Furukawa R; Tateno T
    Brain Res; 2022 Dec; 1796():148092. PubMed ID: 36115587
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modeling transcranial magnetic stimulation coil with magnetic cores.
    Makaroff SN; Nguyen H; Meng Q; Lu H; Nummenmaa AR; Deng ZD
    J Neural Eng; 2023 Jan; 20(1):. PubMed ID: 36548994
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation.
    Lu M; Ueno S
    PLoS One; 2017; 12(6):e0178422. PubMed ID: 28586349
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation method for in situ electric field in standardized human brain for different transcranial magnetic stimulation coils.
    Iwahashi M; Gomez-Tames J; Laakso I; Hirata A
    Phys Med Biol; 2017 Mar; 62(6):2224-2238. PubMed ID: 28222046
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A generalized workflow for conducting electric field-optimized, fMRI-guided, transcranial magnetic stimulation.
    Balderston NL; Roberts C; Beydler EM; Deng ZD; Radman T; Luber B; Lisanby SH; Ernst M; Grillon C
    Nat Protoc; 2020 Nov; 15(11):3595-3614. PubMed ID: 33005039
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.