These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 34891576)

  • 1. Comparison of Coil Designs for Transcranial Magnetic Stimulation of a Pig Model.
    Afuwape OF; Runge J; Bentil SA; Jiles DC
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1535-1538. PubMed ID: 34891576
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.
    Deng ZD; Lisanby SH; Peterchev AV
    Brain Stimul; 2013 Jan; 6(1):1-13. PubMed ID: 22483681
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time computation of the TMS-induced electric field in a realistic head model.
    Stenroos M; Koponen LM
    Neuroimage; 2019 Dec; 203():116159. PubMed ID: 31494248
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical Analysis of the Quadruple Butterfly Coil during Transcranial Magnetic Stimulation and Magnetic Resonance Imaging
    Afuwape OF; Kiarie WM; Bentil SA; Jiles DC
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():1504-1507. PubMed ID: 34891570
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of transcranial magnetic stimulation for major depression: Coil design and neuroanatomical variability considerations.
    Zibman S; Pell GS; Barnea-Ygael N; Roth Y; Zangen A
    Eur Neuropsychopharmacol; 2021 Apr; 45():73-88. PubMed ID: 31285123
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigating the Effects of Anatomical Structures on the Induced Electric Field in the Brain in Transcranial Magnetic Stimulation.
    Zhong X; Jiang H; Jiles DC; Wang Z; Li J; Song B
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():3939-3942. PubMed ID: 36085730
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detailed measurements and simulations of electric field distribution of two TMS coils cleared for obsessive compulsive disorder in the brain and in specific regions associated with OCD.
    Tzirini M; Roth Y; Harmelech T; Zibman S; Pell GS; Kimiskidis VK; Tendler A; Zangen A; Samaras T
    PLoS One; 2022; 17(8):e0263145. PubMed ID: 36040972
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Database of 25 validated coil models for electric field simulations for TMS.
    Drakaki M; Mathiesen C; Siebner HR; Madsen K; Thielscher A
    Brain Stimul; 2022; 15(3):697-706. PubMed ID: 35490970
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of transcranial magnetic stimulation coils with optimal trade-off between depth, focality, and energy.
    Gomez LJ; Goetz SM; Peterchev AV
    J Neural Eng; 2018 Aug; 15(4):046033. PubMed ID: 29855433
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation.
    Lu M; Ueno S
    PLoS One; 2017; 12(6):e0178422. PubMed ID: 28586349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Systematic numerical assessment of occupational exposure to electromagnetic fields of transcranial magnetic stimulation.
    D'Agostino S; Colella M; Liberti M; Falsaperla R; Apollonio F
    Med Phys; 2022 May; 49(5):3416-3431. PubMed ID: 35196394
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deep TMS H7 Coil: Features, Applications & Future.
    Harmelech T; Roth Y; Tendler A
    Expert Rev Med Devices; 2021 Dec; 18(12):1133-1144. PubMed ID: 34878347
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Minimum-energy coils for transcranial magnetic stimulation: application to focal stimulation.
    Koponen LM; Nieminen JO; Ilmoniemi RJ
    Brain Stimul; 2015; 8(1):124-34. PubMed ID: 25458713
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).
    Deng ZD; Peterchev AV; Lisanby SH
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5675-9. PubMed ID: 19164005
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Angle-tuned coils: attractive building blocks for TMS with improved depth-spread performance.
    Bagherzadeh H; Meng Q; Deng ZD; Lu H; Hong E; Yang Y; Choa FS
    J Neural Eng; 2022 May; 19(2):. PubMed ID: 35453132
    [No Abstract]   [Full Text] [Related]  

  • 16. The effect of head and coil modeling for the calculation of induced electric field during transcranial magnetic stimulation.
    Tachas NJ; Samaras T
    Int J Psychophysiol; 2014 Jul; 93(1):167-71. PubMed ID: 23872490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation method for in situ electric field in standardized human brain for different transcranial magnetic stimulation coils.
    Iwahashi M; Gomez-Tames J; Laakso I; Hirata A
    Phys Med Biol; 2017 Mar; 62(6):2224-2238. PubMed ID: 28222046
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coil optimisation for transcranial magnetic stimulation in realistic head geometry.
    Koponen LM; Nieminen JO; Mutanen TP; Stenroos M; Ilmoniemi RJ
    Brain Stimul; 2017; 10(4):795-805. PubMed ID: 28461068
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Coil design considerations for deep transcranial magnetic stimulation.
    Deng ZD; Lisanby SH; Peterchev AV
    Clin Neurophysiol; 2014 Jun; 125(6):1202-12. PubMed ID: 24411523
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 3-axis coil design for multichannel TMS arrays.
    Navarro de Lara LI; Daneshzand M; Mascarenas A; Paulson D; Pratt K; Okada Y; Raij T; Makarov SN; Nummenmaa A
    Neuroimage; 2021 Jan; 224():117355. PubMed ID: 32916290
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.