These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 34892040)

  • 21. MPIGAN: An end-to-end deep based generative framework for high-resolution magnetic particle imaging reconstruction.
    Zhao J; Shen Y; Liu X; Hou X; Ding X; An Y; Hui H; Tian J; Zhang H
    Med Phys; 2024 Aug; 51(8):5492-5509. PubMed ID: 38700948
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hybrid MPI-MRI System for Dual-Modal In Situ Cardiovascular Assessments of Real-Time 3D Blood Flow Quantification-A Pre-Clinical In Vivo Feasibility Investigation.
    Franke J; Baxan N; Lehr H; Heinen U; Reinartz S; Schnorr J; Heidenreich M; Kiessling F; Schulz V
    IEEE Trans Med Imaging; 2020 Dec; 39(12):4335-4345. PubMed ID: 32804645
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Towards human-scale magnetic particle imaging: development of the first system with superconductor-based selection coils.
    Le TA; Bui MP; Hadadian Y; Gadelmowla KM; Oh S; Im C; Hahn S; Yoon J
    IEEE Trans Med Imaging; 2024 Jun; PP():. PubMed ID: 38923478
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Edge Preserving and Noise Reducing Reconstruction for Magnetic Particle Imaging.
    Storath M; Brandt C; Hofmann M; Knopp T; Salamon J; Weber A; Weinmann A
    IEEE Trans Med Imaging; 2017 Jan; 36(1):74-85. PubMed ID: 27455521
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Narrowband magnetic particle imaging.
    Goodwill PW; Scott GC; Stang PP; Conolly SM
    IEEE Trans Med Imaging; 2009 Aug; 28(8):1231-7. PubMed ID: 19211340
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Design of superparamagnetic nanoparticles for magnetic particle imaging (MPI).
    Du Y; Lai PT; Leung CH; Pong PW
    Int J Mol Sci; 2013 Sep; 14(9):18682-710. PubMed ID: 24030719
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Magnetic Particle Imaging for Quantification of Vascular Stenoses: A Phantom Study.
    Herz S; Vogel P; Kampf T; Ruckert MA; Veldhoen S; Behr VC; Bley TA
    IEEE Trans Med Imaging; 2018 Jan; 37(1):61-67. PubMed ID: 28644801
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Joint Reconstruction of Tracer Distribution and Background in Magnetic Particle Imaging.
    Straub M; Schulz V
    IEEE Trans Med Imaging; 2018 May; 37(5):1192-1203. PubMed ID: 29727282
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Magnetic Particle Imaging-Guided Stenting.
    Herz S; Vogel P; Kampf T; Dietrich P; Veldhoen S; Rückert MA; Kickuth R; Behr VC; Bley TA
    J Endovasc Ther; 2019 Aug; 26(4):512-519. PubMed ID: 31131684
    [No Abstract]   [Full Text] [Related]  

  • 30. Size-dependent ferrohydrodynamic relaxometry of magnetic particle imaging tracers in different environments.
    Arami H; Ferguson RM; Khandhar AP; Krishnan KM
    Med Phys; 2013 Jul; 40(7):071904. PubMed ID: 23822441
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Interactive Magnetic Catheter Steering With 3-D Real-Time Feedback Using Multi-Color Magnetic Particle Imaging.
    Rahmer J; Wirtz D; Bontus C; Borgert J; Gleich B
    IEEE Trans Med Imaging; 2017 Jul; 36(7):1449-1456. PubMed ID: 28287965
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Parallel magnetic particle imaging.
    Vogel P; Kampf T; Herz S; Rückert MA; Bley TA; Behr VC
    Rev Sci Instrum; 2020 Apr; 91(4):045117. PubMed ID: 32357760
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fast System Matrix Generation Based on Single Angle Calibration in Open-Sided Field Free Line Magnetic Particle Imaging.
    Li G; Liu Y; Qian Z; Xiong F; Lei S; Feng Y; Li J; Du Y; Tian J; An Y
    IEEE Trans Biomed Eng; 2024 Apr; 71(4):1209-1218. PubMed ID: 37938949
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging.
    He J; Zhang H; Li Y; Li G; Lei S; Qian Z; Xiong F; Feng Y; Zhu T; An Y; Tian J
    IEEE Trans Med Imaging; 2024 May; PP():. PubMed ID: 38781069
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Partial FOV Center Imaging (PCI): A Robust X-Space Image Reconstruction for Magnetic Particle Imaging.
    Kurt S; Muslu Y; Saritas EU
    IEEE Trans Med Imaging; 2020 Nov; 39(11):3441-3450. PubMed ID: 32746094
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Magnetic Particle Imaging: Artifact-Free Metallic Stent Lumen Imaging in a Phantom Study.
    Wegner F; Friedrich T; von Gladiss A; Grzyska U; Sieren MM; Lüdtke-Buzug K; Frydrychowicz A; Buzug TM; Barkhausen J; Haegele J
    Cardiovasc Intervent Radiol; 2020 Feb; 43(2):331-338. PubMed ID: 31578634
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A Novel Field-Free Line Generator for Mechanically Scanned Magnetic Particle Imaging.
    Kim TY; Jeong JC; Seo BS; Krause HJ; Hong HB
    Sensors (Basel); 2024 Jan; 24(3):. PubMed ID: 38339650
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fast System Calibration With Coded Calibration Scenes for Magnetic Particle Imaging.
    Ilbey S; Top CB; Gungor A; Cukur T; Saritas EU; Guven HE
    IEEE Trans Med Imaging; 2019 Sep; 38(9):2070-2080. PubMed ID: 30714915
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A fused LASSO operator for fast 3D magnetic particle imaging reconstruction.
    He J; Li Y; Zhang P; Hui H; Tian J
    Phys Med Biol; 2024 Jun; 69(13):. PubMed ID: 38815602
    [No Abstract]   [Full Text] [Related]  

  • 40. Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model.
    Dietrich P; Vogel P; Kampf T; Rückert MA; Behr VC; Bley TA; Herz S
    Phys Med; 2021 Jan; 81():210-214. PubMed ID: 33477058
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.