187 related articles for article (PubMed ID: 34897703)
1. Convolution neural network toward Monte Carlo photon dose calculation in radiation therapy.
Zhang B; Liu X; Chen L; Zhu J
Med Phys; 2022 Feb; 49(2):1248-1261. PubMed ID: 34897703
[TBL] [Abstract][Full Text] [Related]
2. A preliminary study of a photon dose calculation algorithm using a convolutional neural network.
Zhu J; Liu X; Chen L
Phys Med Biol; 2020 Oct; 65(20):20NT02. PubMed ID: 33063695
[TBL] [Abstract][Full Text] [Related]
3. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
4. Generalisation of radiotherapy dose calculation for Monte Carlo algorithm combined with 3D Swin-Unet: a multi-institutional IMRT evaluation.
Zhang B; Zhuang Y; Li Y; Chen L; Liu X; Liu Z; Wang X; Zhu J
Phys Med Biol; 2023 Oct; 68(21):. PubMed ID: 37827160
[No Abstract] [Full Text] [Related]
5. The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans.
Zarza-Moreno M; Cardoso I; Teixeira N; Jesus AP; Mora G
Phys Med; 2013 Jun; 29(4):357-67. PubMed ID: 22677401
[TBL] [Abstract][Full Text] [Related]
6. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams.
Fotina I; Winkler P; Künzler T; Reiterer J; Simmat I; Georg D
Radiother Oncol; 2009 Dec; 93(3):645-53. PubMed ID: 19926153
[TBL] [Abstract][Full Text] [Related]
7. NeuralDAO: Incorporating neural network generated dose into direct aperture optimization for end-to-end IMRT planning.
Liu C; Ni X; Jin X; Si W
Med Phys; 2021 Oct; 48(10):5624-5638. PubMed ID: 34370880
[TBL] [Abstract][Full Text] [Related]
8. Automatic commissioning of a GPU-based Monte Carlo radiation dose calculation code for photon radiotherapy.
Tian Z; Graves YJ; Jia X; Jiang SB
Phys Med Biol; 2014 Nov; 59(21):6467-86. PubMed ID: 25295381
[TBL] [Abstract][Full Text] [Related]
9. A physically constrained Monte Carlo-Neural Network coupling algorithm for BNCT dose calculation.
Wang Y; Du J; Lin H; Guan X; Zhang L; Li J; Gu L
Med Phys; 2024 Jun; 51(6):4524-4535. PubMed ID: 38299670
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.
Onizuka R; Araki F; Ohno T; Nakaguchi Y; Kai Y; Tomiyama Y; Hioki K
Radiol Phys Technol; 2016 Jan; 9(1):77-87. PubMed ID: 26493992
[TBL] [Abstract][Full Text] [Related]
11. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams.
Künzler T; Fotina I; Stock M; Georg D
Phys Med Biol; 2009 Dec; 54(24):7363-77. PubMed ID: 19934489
[TBL] [Abstract][Full Text] [Related]
12. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance.
Ali I; Ahmad S
Med Dosim; 2013; 38(3):255-61. PubMed ID: 23558145
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric comparison of iPlan
Menon SV; Paramu R; Bhasi S; Gopalakrishnan Z; Bhaskaran S; Nair RK
Med Dosim; 2020 Autumn; 45(3):225-234. PubMed ID: 32001069
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning.
Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ
Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343
[TBL] [Abstract][Full Text] [Related]
15. ARCHERRT - a GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: software development and application to helical tomotherapy.
Su L; Yang Y; Bednarz B; Sterpin E; Du X; Liu T; Ji W; Xu XG
Med Phys; 2014 Jul; 41(7):071709. PubMed ID: 24989378
[TBL] [Abstract][Full Text] [Related]
16. A fast jaw-tracking model for VMAT and IMRT Monte Carlo simulations.
Townson R; Egglestone H; Zavgorodni S
J Appl Clin Med Phys; 2018 Jul; 19(4):26-34. PubMed ID: 29745009
[TBL] [Abstract][Full Text] [Related]
17. A method for photon beam Monte Carlo multileaf collimator particle transport.
Siebers JV; Keall PJ; Kim JO; Mohan R
Phys Med Biol; 2002 Sep; 47(17):3225-49. PubMed ID: 12361220
[TBL] [Abstract][Full Text] [Related]
18. Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions.
Ojala JJ; Kapanen MK; Hyödynmaa SJ; Wigren TK; Pitkänen MA
J Appl Clin Med Phys; 2014 Mar; 15(2):4662. PubMed ID: 24710454
[TBL] [Abstract][Full Text] [Related]
19. New capabilities of the Monte Carlo dose engine ARCHER-RT: Clinical validation of the Varian TrueBeam machine for VMAT external beam radiotherapy.
Adam DP; Liu T; Caracappa PF; Bednarz BP; Xu XG
Med Phys; 2020 Jun; 47(6):2537-2549. PubMed ID: 32175615
[TBL] [Abstract][Full Text] [Related]
20. Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation.
Chow JC; Jiang R; Leung MK
J Appl Clin Med Phys; 2010 Nov; 12(1):3424. PubMed ID: 21330989
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]