These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 34904372)

  • 21. Occipital condyle to cervical spine fixation in the pediatric population.
    Kosnik-Infinger L; Glazier SS; Frankel BM
    J Neurosurg Pediatr; 2014 Jan; 13(1):45-53. PubMed ID: 24206344
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Long-term results of computer-assisted posterior occipitocervical reconstruction.
    Ogihara N; Takahashi J; Hirabayashi H; Hashidate H; Kato H
    World Neurosurg; 2010 Jun; 73(6):722-8. PubMed ID: 20934164
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Occipitocervical fixation: long-term follow-up in fifty-seven patients].
    Stulík J; Klézl Z; Sebesta P; Kryl J; Vyskocil T
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):479-86. PubMed ID: 20067695
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results.
    Pait TG; Al-Mefty O; Boop FA; Arnautovic KI; Rahman S; Ceola W
    J Neurosurg; 1999 Jan; 90(1 Suppl):1-7. PubMed ID: 10413118
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Posterior occipitocervical (C0-3) fusion using polyaxial occipital condyle to cervical spine screw and rod fixation: a radiographic and cadaveric analysis.
    Frankel BM; Hanley M; Vandergrift A; Monroe T; Morgan S; Rumboldt Z
    J Neurosurg Spine; 2010 May; 12(5):509-16. PubMed ID: 20433299
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Anterior occiput to axis screw fixation: part II: a biomechanical comparison with posterior fixation techniques.
    Dvorak MF; Sekeramayi F; Zhu Q; Hoekema J; Fisher C; Boyd M; Goertzen DJ; Oxland TR
    Spine (Phila Pa 1976); 2003 Feb; 28(3):239-45. PubMed ID: 12567024
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Occipitocervical fusion via occipital condylar fixation: a clinical case series.
    Ahmadian A; Dakwar E; Vale FL; Uribe JS
    J Spinal Disord Tech; 2014 Jun; 27(4):232-6. PubMed ID: 24866907
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Outcomes of occipitocervical fixation using a spinous process screw in C2 as a third anchor point for occipitocervical fixation: a case presentation.
    Liu G; Li Q; Sheng F; Xu N; Li M; Wang Y; Ma W
    BMC Musculoskelet Disord; 2020 May; 21(1):307. PubMed ID: 32416720
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical analysis of occipitocervical stability afforded by three fixation techniques.
    Helgeson MD; Lehman RA; Sasso RC; Dmitriev AE; Mack AW; Riew KD
    Spine J; 2011 Mar; 11(3):245-50. PubMed ID: 21377608
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Craniocervical fixation with occipital condyle screws: biomechanical analysis of a novel technique.
    Uribe JS; Ramos E; Youssef AS; Levine N; Turner AW; Johnson WM; Vale FL
    Spine (Phila Pa 1976); 2010 Apr; 35(9):931-8. PubMed ID: 20375778
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Occipital screw pullout strength. A biomechanical investigation of occipital morphology.
    Haher TR; Yeung AW; Caruso SA; Merola AA; Shin T; Zipnick RI; Gorup JM; Bono C
    Spine (Phila Pa 1976); 1999 Jan; 24(1):5-9. PubMed ID: 9921584
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Biomechanical study of anterior occipital condyle screw plate system].
    Peng YJ; Wang Y; Ma WH; Shi KR; Xu DL; Li HJ; Zhou SY; Zhao XC
    Zhonghua Yi Xue Za Zhi; 2021 Aug; 101(29):2299-2303. PubMed ID: 34333945
    [No Abstract]   [Full Text] [Related]  

  • 33. Use of screw-rod system in occipitocervical fixation.
    Hsu YH; Liang ML; Yen YS; Cheng H; Huang CI; Huang WC
    J Chin Med Assoc; 2009 Jan; 72(1):20-8. PubMed ID: 19181593
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A systematic review of occipital cervical fusion: techniques and outcomes.
    Winegar CD; Lawrence JP; Friel BC; Fernandez C; Hong J; Maltenfort M; Anderson PA; Vaccaro AR
    J Neurosurg Spine; 2010 Jul; 13(1):5-16. PubMed ID: 20594011
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Fusion of reconstructed titanic plate, vertebral pedical screws and autogenous granulated cancellous bone graft in posterior occipitocervical region].
    Zhong D; Song Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 Aug; 20(8):825-8. PubMed ID: 16955851
    [TBL] [Abstract][Full Text] [Related]  

  • 36. CT-based morphometric analysis of the occipital condyle: focus on occipital condyle screw insertion.
    Zhou J; Espinoza Orías AA; Kang X; He J; Zhang Z; Inoue N; An HS
    J Neurosurg Spine; 2016 Nov; 25(5):572-579. PubMed ID: 27341056
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients.
    Anderson RC; Ragel BT; Mocco J; Bohman LE; Brockmeyer DL
    J Neurosurg; 2007 Jul; 107(1 Suppl):36-42. PubMed ID: 17644919
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Occipitocervical fusion: fix to C2 or C3?
    Pan J; Huang D; Hao D; Zhao Y; He B; Wu Q; Li H; Ge C
    Clin Neurol Neurosurg; 2014 Dec; 127():134-9. PubMed ID: 25459260
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Posterior cervicothoracic instrumentation in spine tumors.
    Mazel C; Hoffmann E; Antonietti P; Grunenwald D; Henry M; Williams J
    Spine (Phila Pa 1976); 2004 Jun; 29(11):1246-53. PubMed ID: 15167665
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pediatric occipitocervical fixation: radiographic criteria, surgical technique, and clinical outcomes based on experience of a single surgeon.
    Martinez-Del-Campo E; Turner JD; Rangel-Castilla L; Soriano-Baron H; Kalb S; Theodore N
    J Neurosurg Pediatr; 2016 Oct; 18(4):452-462. PubMed ID: 27286444
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.