These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 34915360)

  • 1. Investigation of thermal damage in bone drilling: Hybrid processing method and pathological evaluation of existing methods.
    Can M; Koluaçik S; Bahçe E; Gokce H; Tecellioglu FS
    J Mech Behav Biomed Mater; 2022 Feb; 126():105030. PubMed ID: 34915360
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of machining process and thermal conditions during vibration-assisted cortical bone drilling based on generated bone chip morphologies.
    Bai X; Hou S; Li K; Qu Y; Zhu W
    Med Eng Phys; 2020 Sep; 83():73-81. PubMed ID: 32807351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-vitro experimental analysis and numerical study of temperature in bone drilling.
    Alam K; Khan M; Muhammad R; Qamar SZ; Silberschmidt VV
    Technol Health Care; 2015; 23(6):775-83. PubMed ID: 26409522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone.
    Gupta V; Pandey PM; Gupta RK; Mridha AR
    Proc Inst Mech Eng H; 2017 Mar; 231(3):189-196. PubMed ID: 28116985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental study on biological damage in bone in vibrational drilling.
    Alam K; Iqbal M; Umer J; Amjad M; Al-Ghaithi A
    Biomed Mater Eng; 2020; 31(5):269-277. PubMed ID: 32986649
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone.
    Wang Y; Cao M; Zhao X; Zhu G; McClean C; Zhao Y; Fan Y
    Med Eng Phys; 2014 Nov; 36(11):1408-15. PubMed ID: 24908355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An analytical modeling with experimental validation of bone temperature rise in drilling process.
    Amewoui F; Le Coz G; Bonnet AS; Moufki A
    Med Eng Phys; 2020 Oct; 84():151-160. PubMed ID: 32977912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigation of transient machining in the cortical bone drilling process by conventional and axial vibration-assisted drilling methods.
    Bai X; Qiao G; Liu Z; Zhu W
    Proc Inst Mech Eng H; 2023 Apr; 237(4):489-501. PubMed ID: 36927106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of non-Fourier bioheat transfer on bone drilling temperature in orthopedic surgery: Theoretical and in vitro experimental investigation.
    Kabiri A; Talaee MR
    Proc Inst Mech Eng H; 2022 Jun; 236(6):811-824. PubMed ID: 35486132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of thermal aspects of high-speed drilling of bone by theoretical and experimental approaches.
    Shakouri E; Ghorbani Nezhad M; Ghorbani P; Khosravi-Nejad F
    Phys Eng Sci Med; 2020 Sep; 43(3):959-972. PubMed ID: 32632571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental and analytical investigation of the thermal necrosis in high-speed drilling of bone.
    Shakouri E; Sadeghi MH; Maerefat M; Shajari S
    Proc Inst Mech Eng H; 2014 Apr; 228(4):330-41. PubMed ID: 24569922
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A predictive model for cortical bone temperature distribution during drilling.
    Hu Y; Ding H; Shi Y; Zhang H; Zheng Q
    Phys Eng Sci Med; 2021 Mar; 44(1):147-156. PubMed ID: 33459995
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill.
    Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S
    Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of temperature increase during surgical drilling in acrylic resin.
    Muramoto Y; Fridrici V; Kapsa P; Bouvard G; Ohta M
    Technol Health Care; 2020; 28(4):369-380. PubMed ID: 31796714
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An in vitro study of thermal necrosis in ultrasonic-assisted drilling of bone.
    Shakouri E; Sadeghi MH; Karafi MR; Maerefat M; Farzin M
    Proc Inst Mech Eng H; 2015 Feb; 229(2):137-49. PubMed ID: 25767150
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones.
    Singh RP; Pandey PM; Behera C; Mridha AR
    Proc Inst Mech Eng H; 2020 Aug; 234(8):829-842. PubMed ID: 32490719
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Appraising efficiency of OpSite as coolant in drilling of bone.
    Effatparvar MR; Jamshidi N; Mosavar A
    J Orthop Surg Res; 2020 May; 15(1):197. PubMed ID: 32471512
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques.
    Gupta V; Singh RP; Pandey PM; Gupta R
    Proc Inst Mech Eng H; 2020 Apr; 234(4):398-411. PubMed ID: 32026750
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exploring thermal anisotropy of cortical bone using temperature measurements in drilling.
    Alam K
    Biomed Mater Eng; 2016 May; 27(1):39-48. PubMed ID: 27175466
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modelling and optimization of temperature in orthopaedic drilling: an in vitro study.
    Pandey RK; Panda SS
    Acta Bioeng Biomech; 2014; 16(1):107-16. PubMed ID: 24707883
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.