BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 34922231)

  • 1. Chest compression quality during CPR of potential contagious patients wearing personal protection equipment.
    Cekmen B; Bildik B; Bozan O; Atis SE; Koksal M; Uzuncu HB; Akilli NB
    Am J Emerg Med; 2022 Feb; 52():128-131. PubMed ID: 34922231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chest compression quality comparing 1-min vs 2-min rotation of rescuers wearing N95 masks.
    Mathew MJ; Kundra P; Vinayagam S
    Am J Emerg Med; 2024 Feb; 76():75-81. PubMed ID: 38006635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wearing a N95 mask increases rescuer's fatigue and decreases chest compression quality in simulated cardiopulmonary resuscitation.
    Tian Y; Tu X; Zhou X; Yu J; Luo S; Ma L; Liu C; Zhao Y; Jin X
    Am J Emerg Med; 2021 Jun; 44():434-438. PubMed ID: 33046304
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rescuer-limited cardiopulmonary resuscitation as an alternative to 2-min switched CPR in the setting of inhospital cardiac arrest: a randomised cross-over study.
    Jo CH; Cho GC; Ahn JH; Park YS; Lee CH
    Emerg Med J; 2015 Jul; 32(7):539-43. PubMed ID: 25092797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of Wearing N95 Mask on the Quality of Chest Compressions in Prehospital Emergency Personnel: A Cross-over Study.
    Chen L; Shen Y; Liu S; Cao Y; Zhu Z
    Prehosp Emerg Care; 2023; 27(6):713-717. PubMed ID: 35759255
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rescuer fatigue under the 2010 ERC guidelines, and its effect on cardiopulmonary resuscitation (CPR) performance.
    McDonald CH; Heggie J; Jones CM; Thorne CJ; Hulme J
    Emerg Med J; 2013 Aug; 30(8):623-7. PubMed ID: 22851670
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Decay in quality of closed-chest compressions over time.
    Hightower D; Thomas SH; Stone CK; Dunn K; March JA
    Ann Emerg Med; 1995 Sep; 26(3):300-3. PubMed ID: 7661418
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Does the quality of chest compressions deteriorate when the chest compression rate is above 120/min?
    Lee SH; Kim K; Lee JH; Kim T; Kang C; Park C; Kim J; Jo YH; Rhee JE; Kim DH
    Emerg Med J; 2014 Aug; 31(8):645-8. PubMed ID: 23704754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CPR PRO® device reduces rescuer fatigue during continuous chest compression cardiopulmonary resuscitation: a randomized crossover trial using a manikin model.
    Kovic I; Lulic D; Lulic I
    J Emerg Med; 2013 Oct; 45(4):570-7. PubMed ID: 23845522
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of chest compression rate guidance on the quality of cardiopulmonary resuscitation performed on manikins.
    Jäntti H; Silfvast T; Turpeinen A; Kiviniemi V; Uusaro A
    Resuscitation; 2009 Apr; 80(4):453-7. PubMed ID: 19203821
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rescuer fatigue: standard versus continuous chest-compression cardiopulmonary resuscitation.
    Heidenreich JW; Berg RA; Higdon TA; Ewy GA; Kern KB; Sanders AB
    Acad Emerg Med; 2006 Oct; 13(10):1020-6. PubMed ID: 17015418
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of rescuer fatigue on the quality of chest compressions.
    Ochoa FJ; Ramalle-Gómara E; Lisa V; Saralegui I
    Resuscitation; 1998 Jun; 37(3):149-52. PubMed ID: 9715774
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of one-rescuer compression/ventilation ratios on cardiopulmonary resuscitation in infant, pediatric, and adult manikins.
    Srikantan SK; Berg RA; Cox T; Tice L; Nadkarni VM
    Pediatr Crit Care Med; 2005 May; 6(3):293-7. PubMed ID: 15857527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Which position should we take during newborn resuscitation? A prospective, randomised, multicentre simulation trial.
    Smereka J; Kaminska H; Wieczorek W; Dąbrowski M; Ładny JR; Ruetzler K; Szarpak Ł; Robak O; Frass M
    Kardiol Pol; 2018; 76(6):980-986. PubMed ID: 29350383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quality of chest compressions performed by inexperienced rescuers in simulated cardiac arrest associated with pregnancy.
    Kim S; You JS; Lee HS; Lee JH; Park YS; Chung SP; Park I
    Resuscitation; 2013 Jan; 84(1):98-102. PubMed ID: 22705829
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Brief compression-only cardiopulmonary resuscitation training video and simulation with homemade mannequin improves CPR skills.
    Wanner GK; Osborne A; Greene CH
    BMC Emerg Med; 2016 Nov; 16(1):45. PubMed ID: 27894249
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A 10-s rest improves chest compression quality during hands-only cardiopulmonary resuscitation: a prospective, randomized crossover study using a manikin model.
    Min MK; Yeom SR; Ryu JH; Kim YI; Park MR; Han SK; Lee SH; Cho SJ
    Resuscitation; 2013 Sep; 84(9):1279-84. PubMed ID: 23402967
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quality of cardiopulmonary resuscitation on manikins: on the floor and in the bed.
    Jäntti H; Silfvast T; Turpeinen A; Kiviniemi V; Uusaro A
    Acta Anaesthesiol Scand; 2009 Oct; 53(9):1131-7. PubMed ID: 19388894
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chest compression quality and rescuer fatigue with increased compression to ventilation ratio during single rescuer pediatric CPR.
    Haque IU; Udassi JP; Udassi S; Theriaque DW; Shuster JJ; Zaritsky AL
    Resuscitation; 2008 Oct; 79(1):82-9. PubMed ID: 18617314
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.