These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
252 related articles for article (PubMed ID: 34940278)
41. Diffuse transmittance visible spectroscopy using smartphone flashlight for photoplethysmography and vital signs measurements. Bachir W Spectrochim Acta A Mol Biomol Spectrosc; 2023 Dec; 303():123181. PubMed ID: 37506454 [TBL] [Abstract][Full Text] [Related]
42. Photoplethysmography behind the Ear Outperforms Electrocardiogram for Cardiovascular Monitoring in Dynamic Environments. Bradke BS; Miller TA; Everman B Sensors (Basel); 2021 Jul; 21(13):. PubMed ID: 34283086 [TBL] [Abstract][Full Text] [Related]
43. Respiratory rate and pulse oximetry derived information as predictors of hospital admission in young children in Bangladesh: a prospective observational study. Garde A; Zhou G; Raihana S; Dunsmuir D; Karlen W; Dekhordi P; Huda T; Arifeen SE; Larson C; Kissoon N; Dumont GA; Ansermino JM BMJ Open; 2016 Aug; 6(8):e011094. PubMed ID: 27534987 [TBL] [Abstract][Full Text] [Related]
44. Estimation of Instantaneous Oxygen Uptake During Exercise and Daily Activities Using a Wearable Cardio-Electromechanical and Environmental Sensor. Shandhi MMH; Bartlett WH; Heller JA; Etemadi M; Young A; Plotz T; Inan OT IEEE J Biomed Health Inform; 2021 Mar; 25(3):634-646. PubMed ID: 32750964 [TBL] [Abstract][Full Text] [Related]
45. Free flap pulse oximetry utilizing reflectance photoplethysmography. Zaman T; Kyriacou PA; Pal SK Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4046-9. PubMed ID: 24110620 [TBL] [Abstract][Full Text] [Related]
46. Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO Harju J; Vehkaoja A; Lindroos V; Kumpulainen P; Liuhanen S; Yli-Hankala A; Oksala N J Clin Monit Comput; 2017 Oct; 31(5):1019-1026. PubMed ID: 27752932 [TBL] [Abstract][Full Text] [Related]
47. Technical note: a nose ring sensor system to monitor dairy cow cardiovascular and respiratory metrics. Salzer Y; Lidor G; Rosenfeld L; Reshef L; Shaked B; Grinshpun J; Honig HH; Kamer H; Balaklav M; Ross M J Anim Sci; 2022 Sep; 100(9):. PubMed ID: 35921498 [TBL] [Abstract][Full Text] [Related]
48. Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection-reduction approach. Part I: Motion and noise artifact detection. Chong JW; Dao DK; Salehizadeh SM; McManus DD; Darling CE; Chon KH; Mendelson Y Ann Biomed Eng; 2014 Nov; 42(11):2238-50. PubMed ID: 25092422 [TBL] [Abstract][Full Text] [Related]
49. PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities. Solé Morillo Á; Lambert Cause J; Baciu VE; da Silva B; Garcia-Naranjo JC; Stiens J Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214290 [TBL] [Abstract][Full Text] [Related]
50. Machine Learning-Based Respiration Rate and Blood Oxygen Saturation Estimation Using Photoplethysmogram Signals. Shuzan MNI; Chowdhury MH; Chowdhury MEH; Murugappan M; Hoque Bhuiyan E; Arslane Ayari M; Khandakar A Bioengineering (Basel); 2023 Jan; 10(2):. PubMed ID: 36829661 [TBL] [Abstract][Full Text] [Related]
51. Investigation of pulse oximeter failure rates during artificial hypoperfusion utilising a custom made multimode pulse oximetery sensor. Shafique M; Kyriacou PA; Pal SK Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():4352-5. PubMed ID: 22255303 [TBL] [Abstract][Full Text] [Related]
52. Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System. Shao D; Liu C; Tsow F; Yang Y; Du Z; Iriya R; Yu H; Tao N IEEE Trans Biomed Eng; 2016 Jun; 63(6):1091-8. PubMed ID: 26415199 [TBL] [Abstract][Full Text] [Related]
53. Evaluation of key design parameters for mitigating motion artefact in the mobile reflectance PPG signal to improve estimation of arterial oxygenation. Kasbekar RS; Mendelson Y Physiol Meas; 2018 Jul; 39(7):075008. PubMed ID: 30051881 [TBL] [Abstract][Full Text] [Related]
54. Estimating SpO Chan M; Zhu L; Vatanparvar K; Gwak M; Kuang J; Gao A Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-5. PubMed ID: 38083548 [TBL] [Abstract][Full Text] [Related]
55. An efficient model for extracting respiratory and blood oxygen saturation data from photoplethysmogram signals by removing motion artifacts using heuristic-aided ensemble learning model. Bondala VR; Komalla AR Comput Biol Med; 2024 Sep; 180():108911. PubMed ID: 39089111 [TBL] [Abstract][Full Text] [Related]
57. Calibration of Contactless Pulse Oximetry. Verkruysse W; Bartula M; Bresch E; Rocque M; Meftah M; Kirenko I Anesth Analg; 2017 Jan; 124(1):136-145. PubMed ID: 27258081 [TBL] [Abstract][Full Text] [Related]
58. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation. Budidha K; Kyriacou PA Physiol Meas; 2014 Feb; 35(2):111-28. PubMed ID: 24399082 [TBL] [Abstract][Full Text] [Related]
59. Posture effects on the calibratability of remote pulse oximetry in visible light. Moço A; Stuijk S; de Haan G Physiol Meas; 2019 Apr; 40(3):035005. PubMed ID: 30731445 [TBL] [Abstract][Full Text] [Related]
60. Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review. Charlton PH; Birrenkott DA; Bonnici T; Pimentel MAF; Johnson AEW; Alastruey J; Tarassenko L; Watkinson PJ; Beale R; Clifton DA IEEE Rev Biomed Eng; 2018; 11():2-20. PubMed ID: 29990026 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]