163 related articles for article (PubMed ID: 34945380)
1. Mixing Performance of a Passive Micro-Mixer with Mixing Units Stacked in Cross Flow Direction.
Juraeva M; Kang DJ
Micromachines (Basel); 2021 Dec; 12(12):. PubMed ID: 34945380
[TBL] [Abstract][Full Text] [Related]
2. Mixing Performance of a Cross-Channel Split-and-Recombine Micro-Mixer Combined with Mixing Cell.
Juraeva M; Kang DJ
Micromachines (Basel); 2020 Jul; 11(7):. PubMed ID: 32679732
[TBL] [Abstract][Full Text] [Related]
3. Mixing Performance of a 3D Micro T-Mixer with Swirl-Inducing Inlets and Rectangular Constriction.
Zhang J; Luo X
Micromachines (Basel); 2018 Apr; 9(5):. PubMed ID: 30424132
[TBL] [Abstract][Full Text] [Related]
4. Optimal Combination of Mixing Units Using the Design of Experiments Method.
Juraeva M; Kang DJ
Micromachines (Basel); 2021 Aug; 12(8):. PubMed ID: 34442607
[TBL] [Abstract][Full Text] [Related]
5. Mixing Performance of a Passive Micromixer Based on Multiple Baffles and Submergence Scheme.
Juraeva M; Kang DJ
Micromachines (Basel); 2023 May; 14(5):. PubMed ID: 37241701
[TBL] [Abstract][Full Text] [Related]
6. Mixing Enhancement of a Passive Micromixer with Submerged Structures.
Juraeva M; Kang DJ
Micromachines (Basel); 2022 Jun; 13(7):. PubMed ID: 35888870
[TBL] [Abstract][Full Text] [Related]
7. Numerical and Experimental Study on Mixing Performances of Simple and Vortex Micro T-Mixers.
Ansari MA; Kim KY; Kim SM
Micromachines (Basel); 2018 Apr; 9(5):. PubMed ID: 30424137
[TBL] [Abstract][Full Text] [Related]
8. Mixing Performance of a Passive Micromixer Based on Split-to-Circulate (STC) Flow Characteristics.
Juraeva M; Kang DJ
Micromachines (Basel); 2024 Jun; 15(6):. PubMed ID: 38930743
[TBL] [Abstract][Full Text] [Related]
9. Mixing Performance Analysis and Optimal Design of a Novel Passive Baffle Micromixer.
Zheng Y; Liu Y; Tang C; Liu B; Zou H; Li W; Zhang H
Micromachines (Basel); 2024 Jan; 15(2):. PubMed ID: 38398912
[TBL] [Abstract][Full Text] [Related]
10. Kinematic Measurements of Novel Chaotic Micromixers to Enhance Mixing Performances at Low Reynolds Numbers: Comparative Study.
Naas TT; Hossain S; Aslam M; Rahman A; Hoque ASM; Kim KY; Islam SMR
Micromachines (Basel); 2021 Mar; 12(4):. PubMed ID: 33800534
[TBL] [Abstract][Full Text] [Related]
11. Influence of Structural Parameters on the Performance of an Asymmetric Rhombus Micromixer with Baffles.
Nai J; Zhang F; Dong P; Fu T; Ge A; Xu S; Pan Y
Micromachines (Basel); 2023 Feb; 14(3):. PubMed ID: 36984952
[TBL] [Abstract][Full Text] [Related]
12. Mixing enhancement of the passive microfluidic mixer with J-shaped baffles in the tee channel.
Lin YC; Chung YC; Wu CY
Biomed Microdevices; 2007 Apr; 9(2):215-21. PubMed ID: 17165126
[TBL] [Abstract][Full Text] [Related]
13. Effect of Multiple Structural Parameters on the Performance of a Micromixer with Baffles, Obstacles, and Gaps.
Nai J; Zhang F; Dong P; Bai F; Fu T; Wang J; Ge A
Micromachines (Basel); 2023 Sep; 14(9):. PubMed ID: 37763914
[TBL] [Abstract][Full Text] [Related]
14. Computational modeling of passive furrowed channel micromixers for lab-on-a-chip applications.
Nason F; Pennati G; Dubini G
J Appl Biomater Funct Mater; 2014 Dec; 12(3):278-85. PubMed ID: 24700264
[TBL] [Abstract][Full Text] [Related]
15. Mixing Enhancement in Serpentine Micromixers with a Non-Rectangular Cross-Section.
Clark J; Kaufman M; Fodor PS
Micromachines (Basel); 2018 Mar; 9(3):. PubMed ID: 30424041
[TBL] [Abstract][Full Text] [Related]
16. Convex Grooves in Staggered Herringbone Mixer Improve Mixing Efficiency of Laminar Flow in Microchannel.
Kwak TJ; Nam YG; Najera MA; Lee SW; Strickler JR; Chang WJ
PLoS One; 2016; 11(11):e0166068. PubMed ID: 27814386
[TBL] [Abstract][Full Text] [Related]
17. Mixing Performance of the Modified Tesla Micromixer with Tip Clearance.
Juraeva M; Kang DJ
Micromachines (Basel); 2022 Aug; 13(9):. PubMed ID: 36143998
[TBL] [Abstract][Full Text] [Related]
18. Biophysical micromixer.
Wang CT; Hu YC; Hu TY
Sensors (Basel); 2009; 9(7):5379-89. PubMed ID: 22346704
[TBL] [Abstract][Full Text] [Related]
19. Asymmetrical Split-and-Recombine Micromixer with Baffles.
Raza W; Kim KY
Micromachines (Basel); 2019 Dec; 10(12):. PubMed ID: 31816973
[TBL] [Abstract][Full Text] [Related]
20. Design of passive mixers utilizing microfluidic self-circulation in the mixing chamber.
Chung YC; Hsu YL; Jen CP; Lu MC; Lin YC
Lab Chip; 2004 Feb; 4(1):70-7. PubMed ID: 15007444
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]