128 related articles for article (PubMed ID: 34949138)
1. Feasibility of heating metal implants with alternating magnetic fields (AMF) in scaled up models.
Sadaphal V; Prasad B; Kay W; Nehring L; Nyugen T; Tepper J; Tanner M; Williams D; Ashton N; Greenberg DE; Chopra R
Int J Hyperthermia; 2022; 39(1):81-96. PubMed ID: 34949138
[No Abstract] [Full Text] [Related]
2. Remote acoustic sensing as a safety mechanism during exposure of metal implants to alternating magnetic fields.
Cheng B; Chatzinoff Y; Szczepanski D; Bing C; Shaikh S; Wyman O; Perry CE; Richardson JA; Burns DK; Evers BM; Greenberg DE; Chopra R
PLoS One; 2018; 13(5):e0197380. PubMed ID: 29746579
[TBL] [Abstract][Full Text] [Related]
3. Quantifying the relationship between biofilm reduction and thermal tissue damage on metal implants exposed to alternating magnetic fields.
Prasad B; Shaikh S; Saini R; Wang Q; Zadoo S; Sadaphal V; Greenberg DE; Chopra R
Int J Hyperthermia; 2022; 39(1):713-724. PubMed ID: 35634916
[TBL] [Abstract][Full Text] [Related]
4. Employing high-frequency alternating magnetic fields for the non-invasive treatment of prosthetic joint infections.
Chopra R; Shaikh S; Chatzinoff Y; Munaweera I; Cheng B; Daly SM; Xi Y; Bing C; Burns D; Greenberg DE
Sci Rep; 2017 Aug; 7(1):7520. PubMed ID: 28790407
[TBL] [Abstract][Full Text] [Related]
5. Design and Assessment of a Novel Biconical Human-Sized Alternating Magnetic Field Coil for MNP Hyperthermia Treatment of Deep-Seated Cancer.
Shoshiashvili L; Shamatava I; Kakulia D; Shubitidze F
Cancers (Basel); 2023 Mar; 15(6):. PubMed ID: 36980560
[TBL] [Abstract][Full Text] [Related]
6. Method to reduce non-specific tissue heating of small animals in solenoid coils.
Kumar A; Attaluri A; Mallipudi R; Cornejo C; Bordelon D; Armour M; Morua K; Deweese TL; Ivkov R
Int J Hyperthermia; 2013; 29(2):106-20. PubMed ID: 23402327
[TBL] [Abstract][Full Text] [Related]
7. Temperature-sensitive liposomal ciprofloxacin for the treatment of biofilm on infected metal implants using alternating magnetic fields.
Munaweera I; Shaikh S; Maples D; Nigatu AS; Sethuraman SN; Ranjan A; Greenberg DE; Chopra R
Int J Hyperthermia; 2018 Mar; 34(2):189-200. PubMed ID: 29498309
[TBL] [Abstract][Full Text] [Related]
8. Application of high amplitude alternating magnetic fields for heat induction of nanoparticles localized in cancer.
Ivkov R; DeNardo SJ; Daum W; Foreman AR; Goldstein RC; Nemkov VS; DeNardo GL
Clin Cancer Res; 2005 Oct; 11(19 Pt 2):7093s-7103s. PubMed ID: 16203808
[TBL] [Abstract][Full Text] [Related]
9. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T.
Destruel A; Fuentes M; Weber E; O'Brien K; Jin J; Liu F; Barth M; Crozier S
Magn Reson Med; 2019 Jun; 81(6):3826-3839. PubMed ID: 30803001
[TBL] [Abstract][Full Text] [Related]
10. Intermittent alternating magnetic fields diminish metal-associated biofilm in vivo.
Shaikh S; Lapin NA; Prasad B; Sturge CR; Pybus C; Pifer R; Wang Q; Evers BM; Chopra R; Greenberg DE
Sci Rep; 2023 Dec; 13(1):22456. PubMed ID: 38105253
[TBL] [Abstract][Full Text] [Related]
11. Transcutaneous Recharge: A Comparison of Numerical Simulation to In Vivo Experiments.
Plourde B; Vallez L; Nelson-Cheeseman B; Abraham J
Neuromodulation; 2017 Aug; 20(6):613-621. PubMed ID: 28653422
[TBL] [Abstract][Full Text] [Related]
12. Magnetothermoacoustics from magnetic nanoparticles by short bursting or frequency chirped alternating magnetic field: a theoretical feasibility analysis.
Piao D; Towner RA; Smith N; Chen WR
Med Phys; 2013 Jun; 40(6):063301. PubMed ID: 23718611
[TBL] [Abstract][Full Text] [Related]
13. MR safety assessment of potential RF heating from cranial fixation plates at 7 T.
Kraff O; Wrede KH; Schoemberg T; Dammann P; Noureddine Y; Orzada S; Ladd ME; Bitz AK
Med Phys; 2013 Apr; 40(4):042302. PubMed ID: 23556915
[TBL] [Abstract][Full Text] [Related]
14. Parameters Affecting Worst-Case Gradient-Field Heating of Passive Conductive Implants.
Bassen H; Zaidi T
J Magn Reson Imaging; 2022 Oct; 56(4):1197-1204. PubMed ID: 35778374
[TBL] [Abstract][Full Text] [Related]
15. Validation of a coupled electromagnetic and thermal model for estimating temperatures during magnetic nanoparticle hyperthermia.
Kandala SK; Sharma A; Mirpour S; Liapi E; Ivkov R; Attaluri A
Int J Hyperthermia; 2021; 38(1):611-622. PubMed ID: 33853493
[TBL] [Abstract][Full Text] [Related]
16. Segmental induction heating of orthopaedic metal implants.
Pijls BG; Sanders IMJG; Kuijper EJ; Nelissen RGHH
Bone Joint Res; 2018 Nov; 7(11):609-619. PubMed ID: 30581559
[TBL] [Abstract][Full Text] [Related]
17. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
Busch MH; Vollmann W; Grönemeyer DH
Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
[TBL] [Abstract][Full Text] [Related]
18. On the accuracy of Tier 4 simulations to predict RF heating of wire implants during magnetic resonance imaging at 1.5 T.
Sanpitak P; Bhusal B; Nguyen BT; Vu J; Chow K; Bi X; Golestanirad L
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():4982-4985. PubMed ID: 34892326
[TBL] [Abstract][Full Text] [Related]
19. Numerical Simulations of Realistic Lead Trajectories and an Experimental Verification Support the Efficacy of Parallel Radiofrequency Transmission to Reduce Heating of Deep Brain Stimulation Implants during MRI.
McElcheran CE; Golestanirad L; Iacono MI; Wei PS; Yang B; Anderson KJT; Bonmassar G; Graham SJ
Sci Rep; 2019 Feb; 9(1):2124. PubMed ID: 30765724
[TBL] [Abstract][Full Text] [Related]
20. Modified Solenoid Coil That Efficiently Produces High Amplitude AC Magnetic Fields With Enhanced Uniformity for Biomedical Applications.
Bordelon DE; Goldstein RC; Nemkov VS; Kumar A; Jackowski JK; DeWeese TL; Ivkov R
IEEE Trans Magn; 2012 Oct; 48(1):47-52. PubMed ID: 25392562
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]