BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 34972495)

  • 1. Clamped percutaneous Poller screws to assist intramedullary nailing of proximal third tibia shaft fractures.
    Abdalaziz H; Bates P; Iliadis A; Vris A
    Ann R Coll Surg Engl; 2022 Jan; 104(1):74-75. PubMed ID: 34972495
    [No Abstract]   [Full Text] [Related]  

  • 2. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws.
    Ricci WM; O'Boyle M; Borrelli J; Bellabarba C; Sanders R
    J Orthop Trauma; 2001 May; 15(4):264-70. PubMed ID: 11371791
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Poller Screw Technique: A Method of Fine-Tuning the Reduction in Locked Nailing.
    Koller T; Mühlebach J; Livingston A; Boopalan PRJVC; Iselin LD
    J Foot Ankle Surg; 2020; 59(3):638-640. PubMed ID: 32354521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Do Poller screws effect union in tibial shaft fractures treated with intramedullary nailing?
    Peat F; Ordas-Bayon A; Krkovic M
    Injury; 2021 Oct; 52(10):3132-3138. PubMed ID: 33627250
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Controversies in the intramedullary nailing of proximal and distal tibia fractures.
    Tejwani N; Polonet D; Wolinsky PR
    J Am Acad Orthop Surg; 2014 Oct; 22(10):665-73. PubMed ID: 25281261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technique for precise placement of poller screws with intramedullary nailing of metaphyseal fractures of the femur and the tibia.
    Shahulhameed A; Roberts CS; Ojike NI
    Injury; 2011 Feb; 42(2):136-9. PubMed ID: 20488439
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcome Analysis of Intramedullary Nailing Augmented with Poller Screws for Treating Difficult Reduction Fractures of Femur and Tibia: a Retrospective Cohort Study.
    Guo J; Zha J; Di J; Yin Y; Hou Z; Zhang Y
    Biomed Res Int; 2021; 2021():6615776. PubMed ID: 33869628
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary nailing of extra-articular proximal tibia fractures.
    Hiesterman TG; Shafiq BX; Cole PA
    J Am Acad Orthop Surg; 2011 Nov; 19(11):690-700. PubMed ID: 22052645
    [TBL] [Abstract][Full Text] [Related]  

  • 9. "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.
    Belangero WD; Santos Pires RE; Livani B; Rossi FL; de Andrade ALL
    Eur J Orthop Surg Traumatol; 2018 May; 28(4):721-725. PubMed ID: 29362975
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intramedullary nailing supplemented with Poller screws for proximal tibial fractures.
    Kulkarni SG; Varshneya A; Kulkarni S; Kulkarni GS; Kulkarni MG; Kulkarni VS; Kulkarni RM
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):307-11. PubMed ID: 23255635
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Poller blocking screw augmentation to treat delayed union of proximal tibial shaft fracture after locked IM nailing.
    Ferreli A; Nonne D; Russo A; Dessì G; Marongiu G
    Acta Biomed; 2021 Jan; 91(4):e2020119. PubMed ID: 33525305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intramedullary nailing with supplementary screw fixation (Grosse-Kempf technique).
    Zanasi R; Fioretta G; Rotolo F
    Ital J Orthop Traumatol; 1985 Jun; 11(2):159-64. PubMed ID: 4066286
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Elastic stable intramedullary nailing (ESIN) in paediatric femur and tibia shaft fractures: Comparison between titanium and stainless steel nails.
    Marengo L; Nasto LA; Michelis MB; Boero S
    Injury; 2018 Nov; 49 Suppl 3():S8-S11. PubMed ID: 30415674
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].
    El Attal R; Hansen M; Rosenberger R; Smekal V; Rommens PM; Blauth M
    Oper Orthop Traumatol; 2011 Dec; 23(5):397-410. PubMed ID: 22159844
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intramedullary nailing supplemented with Poller screws for proximal tibial fractures.
    Oytun I; Marangoz S
    J Orthop Surg (Hong Kong); 2013 Apr; 21(1):134. PubMed ID: 23630009
    [No Abstract]   [Full Text] [Related]  

  • 16. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
    Vallier HA; Cureton BA; Patterson BM
    J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Commentary: Intramedullary nailing supplemented with Poller screws for proximal tibial fractures.
    Leung F
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):286. PubMed ID: 23255629
    [No Abstract]   [Full Text] [Related]  

  • 18. Reamed or unreamed nailing for closed tibial fractures. A prospective study in Tscherne C1 fractures.
    Court-Brown CM; Will E; Christie J; McQueen MM
    J Bone Joint Surg Br; 1996 Jul; 78(4):580-3. PubMed ID: 8682824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flexible intramedullary nailing of tibial shaft fractures.
    Segal D
    Instr Course Lect; 1987; 36():338-49. PubMed ID: 3437134
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Indirect reduction screws: a technique to aid reduction in intramedullary nailing.
    Sivakumar BS; Athreya PJ; Ruff SJ
    Ann R Coll Surg Engl; 2019 Mar; 101(3):226-227. PubMed ID: 30286629
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.