115 related articles for article (PubMed ID: 34976288)
1. Increased Uniformity in Diagnostic Accuracy of Pigmented Lesions Using Electrical Impedance Spectroscopy Information.
Litchman G; Teplitz R; Svoboda RM; Del Rosso JQ
J Clin Aesthet Dermatol; 2021 Oct; 14(10):35-36. PubMed ID: 34976288
[TBL] [Abstract][Full Text] [Related]
2. Electrical impedance spectroscopy significantly enhances correct biopsy choice for pigmented skin lesions beyond clinical evaluation and dermoscopy.
Zakria D; Brownstone N; Han J; Owji S; Dirr M; Rigel D
Melanoma Res; 2023 Feb; 33(1):80-83. PubMed ID: 36223289
[TBL] [Abstract][Full Text] [Related]
3. Analysis of an electrical impedance spectroscopy system in short-term digital dermoscopy imaging of melanocytic lesions.
Rocha L; Menzies SW; Lo S; Avramidis M; Khoury R; Jackett L; Guitera P
Br J Dermatol; 2017 Nov; 177(5):1432-1438. PubMed ID: 28421597
[TBL] [Abstract][Full Text] [Related]
4. Use of electrical impedance spectroscopy to detect malignant and potentially malignant oral lesions.
Murdoch C; Brown BH; Hearnden V; Speight PM; D'Apice K; Hegarty AM; Tidy JA; Healey TJ; Highfield PE; Thornhill MH
Int J Nanomedicine; 2014; 9():4521-32. PubMed ID: 25285005
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of electrical impedance spectroscopy as an adjunct to dermoscopy in short-term monitoring of atypical melanocytic lesions.
Ceder H; Hylén AS; Larkö AW; Paoli J
Dermatol Pract Concept; 2016 Oct; 6(4):1-6. PubMed ID: 27867738
[TBL] [Abstract][Full Text] [Related]
6. The impact of lesion vascularisation on tumours detection by electrical impedance scanning at 200 Hz.
Malich A; Scholz B; Kott A; Facius M; Fischer D; Freesmeyer M
Biomed Imaging Interv J; 2007 Oct; 3(4):e33. PubMed ID: 21614295
[TBL] [Abstract][Full Text] [Related]
7. The Impact of Quantitative Data Provided by a Multi-spectral Digital Skin Lesion Analysis Device on Dermatologists'Decisions to Biopsy Pigmented Lesions.
Farberg AS; Winkelmann RR; Tucker N; White R; Rigel DS
J Clin Aesthet Dermatol; 2017 Sep; 10(9):24-26. PubMed ID: 29344323
[No Abstract] [Full Text] [Related]
8. Diagnostic potential of targeted electrical impedance scanning in classifying suspicious breast lesions.
Wersebe A; Siegmann K; Krainick U; Fersis N; Vogel U; Claussen CD; Müller-Schimpfle M
Invest Radiol; 2002 Feb; 37(2):65-72. PubMed ID: 11799329
[TBL] [Abstract][Full Text] [Related]
9. Retrospective evaluation of the performance of the electrical impedance spectroscopy system Nevisense in detecting keratinocyte cancers.
Liebich C; von Bruehl ML; Schubert I; Oberhoffer R; Sander C
Skin Res Technol; 2021 Sep; 27(5):723-729. PubMed ID: 33511695
[TBL] [Abstract][Full Text] [Related]
10. A Review of Noninvasive Techniques for Skin Cancer Detection in Dermatology.
Heibel HD; Hooey L; Cockerell CJ
Am J Clin Dermatol; 2020 Aug; 21(4):513-524. PubMed ID: 32383142
[TBL] [Abstract][Full Text] [Related]
11. Enhancement of International Dermatologists' Pigmented Skin Lesion Biopsy Decisions Following Dermoscopy with Subsequent Integration of Multispectral Digital Skin Lesion Analysis.
Winkelmann RR; Farberg AS; Tucker N; White R; Rigel DS
J Clin Aesthet Dermatol; 2016 Jul; 9(7):53-5. PubMed ID: 27672411
[TBL] [Abstract][Full Text] [Related]
12. Cancer Detection Based on Electrical Impedance Spectroscopy: A Clinical Study.
Moqadam SM; Grewal PK; Haeri Z; Ingledew PA; Kohli K; Golnaraghi F
J Electr Bioimpedance; 2018 Jan; 9(1):17-23. PubMed ID: 33584916
[TBL] [Abstract][Full Text] [Related]
13. Impact of Guidance Provided by a Multispectral Digital Skin Lesion Analysis Device Following Dermoscopy on Decisions to Biopsy Atypical Melanocytic Lesions.
Winkelmann RR; Yoo J; Tucker N; White R; Rigel DS
J Clin Aesthet Dermatol; 2015 Sep; 8(9):21-4. PubMed ID: 26430487
[TBL] [Abstract][Full Text] [Related]
14. Electrical property sensing biopsy needle for prostate cancer detection.
Mishra V; Schned AR; Hartov A; Heaney JA; Seigne J; Halter RJ
Prostate; 2013 Nov; 73(15):1603-13. PubMed ID: 23996675
[TBL] [Abstract][Full Text] [Related]
15. Differentiation of mammographically suspicious lesions: evaluation of breast ultrasound, MRI mammography and electrical impedance scanning as adjunctive technologies in breast cancer detection.
Malich A; Boehm T; Facius M; Freesmeyer MG; Fleck M; Anderson R; Kaiser WA
Clin Radiol; 2001 Apr; 56(4):278-83. PubMed ID: 11286578
[TBL] [Abstract][Full Text] [Related]
16. Influence of size and depth on accuracy of electrical impedance scanning.
Malich A; Facius M; Anderson R; Böttcher J; Sauner D; Hansch A; Marx C; Petrovitch A; Pfleiderer S; Kaiser W
Eur Radiol; 2003 Nov; 13(11):2441-6. PubMed ID: 12845465
[TBL] [Abstract][Full Text] [Related]
17. Electrical impedance spectroscopy as electrical biopsy for monitoring radiation sequelae of intestine in rats.
Chao PJ; Huang EY; Cheng KS; Huang YJ
Biomed Res Int; 2013; 2013():974614. PubMed ID: 24093111
[TBL] [Abstract][Full Text] [Related]
18. Electrical Impedance Spectroscopy in Skin Cancer Diagnosis.
Braun RP; Mangana J; Goldinger S; French L; Dummer R; Marghoob AA
Dermatol Clin; 2017 Oct; 35(4):489-493. PubMed ID: 28886804
[TBL] [Abstract][Full Text] [Related]
19. Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography.
Murphy EK; Mahara A; Khan S; Hyams ES; Schned AR; Pettus J; Halter RJ
Physiol Meas; 2017 Jun; 38(6):1242-1261. PubMed ID: 28282026
[TBL] [Abstract][Full Text] [Related]
20. The negative predictive value of electrical impedance scanning in BI-RADS category IV breast lesions.
Fuchsjaeger MH; Flöry D; Reiner CS; Rudas M; Riedl CC; Helbich TH
Invest Radiol; 2005 Jul; 40(7):478-85. PubMed ID: 15973141
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]