These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 34989838)

  • 21. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring.
    Willemink MJ; den Harder AM; Foppen W; Schilham AM; Rienks R; Laufer EM; Nieman K; de Jong PA; Budde RP; Nathoe HM; Leiner T
    J Cardiovasc Comput Tomogr; 2016; 10(1):69-75. PubMed ID: 26342405
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography.
    Nakazato R; Dey D; Gutstein A; Le Meunier L; Cheng VY; Pimentel R; Paz W; Hayes SW; Thomson LE; Friedman JD; Berman DS
    J Cardiovasc Comput Tomogr; 2009; 3(6):394-400. PubMed ID: 20083060
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Controversies about effects of low-kilovoltage MDCT acquisition on Agatston calcium scoring.
    Deprez FC; Vlassenbroek A; Ghaye B; Raaijmakers R; Coche E
    J Cardiovasc Comput Tomogr; 2013; 7(1):58-61. PubMed ID: 23333185
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Adaptive Iterative Dose Reduction 3D Integrated with Automatic Tube Current Modulation for CT Coronary Artery Calcium Quantification: Comparison to Traditional Filtered Back Projection in an Anthropomorphic Phantom and Patients.
    Tang YC; Liu YC; Hsu MY; Tsai HY; Chen CM
    Acad Radiol; 2018 Aug; 25(8):1010-1017. PubMed ID: 29395796
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Coronary calcium scores on dual-source photon-counting computed tomography: an adapted Agatston methodology aimed at radiation dose reduction.
    van der Werf NR; Greuter MJW; Booij R; van der Lugt A; Budde RPJ; van Straten M
    Eur Radiol; 2022 Aug; 32(8):5201-5209. PubMed ID: 35230517
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Ultra-low-dose coronary artery calcium scoring using novel scoring thresholds for low tube voltage protocols-a pilot study.
    Gräni C; Vontobel J; Benz DC; Bacanovic S; Giannopoulos AA; Messerli M; Grossmann M; Gebhard C; Pazhenkottil AP; Gaemperli O; Kaufmann PA; Buechel RR
    Eur Heart J Cardiovasc Imaging; 2018 Dec; 19(12):1362-1371. PubMed ID: 29432592
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Coronary Artery Calcium Scoring: Toward a New Standard.
    van Praagh GD; Wang J; van der Werf NR; Greuter MJW; Mastrodicasa D; Nieman K; van Hamersvelt RW; Oostveen LJ; de Lange F; Slart RHJA; Leiner T; Fleischmann D; Willemink MJ
    Invest Radiol; 2022 Jan; 57(1):13-22. PubMed ID: 34261083
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessment of isotropic calcium using 0.5-mm reconstructions from 320-row CT data sets identifies more patients with non-zero Agatston score and more subclinical atherosclerosis than standard 3.0-mm coronary artery calcium scan and CT angiography.
    Aslam A; Khokhar US; Chaudhry A; Abramowicz A; Rajper N; Cortegiano M; Poon M; Voros S
    J Cardiovasc Comput Tomogr; 2014; 8(1):58-66. PubMed ID: 24582044
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Impact of Hybrid Iterative Reconstruction on Agatston Coronary Artery Calcium Scores in Comparison to Filtered Back Projection in Native Cardiac CT.
    Obmann VC; Klink T; Heverhagen JT; Stork A; Laqmani A; Adam G; Begemann PG
    Rofo; 2015 May; 187(5):372-9. PubMed ID: 25962672
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction.
    Hou KY; Tsujioka K; Yang CC
    J Appl Clin Med Phys; 2020 Feb; 21(2):111-120. PubMed ID: 31889419
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial.
    Hausleiter J; Martinoff S; Hadamitzky M; Martuscelli E; Pschierer I; Feuchtner GM; Catalán-Sanz P; Czermak B; Meyer TS; Hein F; Bischoff B; Kuse M; Schömig A; Achenbach S
    JACC Cardiovasc Imaging; 2010 Nov; 3(11):1113-23. PubMed ID: 21070998
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Coronary calcium scoring from contrast coronary CT angiography using a semiautomated standardized method.
    Schuhbaeck A; Otaki Y; Achenbach S; Schneider C; Slomka P; Berman DS; Dey D
    J Cardiovasc Comput Tomogr; 2015; 9(5):446-53. PubMed ID: 26169700
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Coronary artery calcium scoring at lower tube voltages - Dose determination and scoring mechanism.
    Zhang D; Scott A; Lee C; Gellada N; Hyun M; Zhou Y
    Eur J Radiol; 2021 Jun; 139():109680. PubMed ID: 33848779
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Coronary artery calcification on low-dose computed tomography: comparison of Agatston and Ordinal Scores.
    Htwe Y; Cham MD; Henschke CI; Hecht H; Shemesh J; Liang M; Tang W; Jirapatnakul A; Yip R; Yankelevitz DF
    Clin Imaging; 2015; 39(5):799-802. PubMed ID: 26068098
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images.
    Pavitt CW; Harron K; Lindsay AC; Zielke S; Ray R; Gordon D; Rubens MB; Padley SP; Nicol ED
    Eur Radiol; 2016 May; 26(5):1493-502. PubMed ID: 26253256
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Calibration of coronary calcium scores determined using iterative image reconstruction (AIDR 3D) at 120, 100, and 80 kVp.
    Blobel J; Mews J; Goatman KA; Schuijf JD; Overlaet W
    Med Phys; 2016 Apr; 43(4):1921. PubMed ID: 27036588
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness.
    Kang HW; Ahn WJ; Jeong JH; Suh YJ; Yang DH; Choi H; Hwang SH; Yong HS; Oh YW; Kang EY; Kim C
    Eur Radiol; 2023 Mar; 33(3):1973-1981. PubMed ID: 36152039
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality.
    Ippolito D; Riva L; Talei Franzesi CR; Cangiotti C; De Vito A; Di Gennaro F; D'andrea G; Crespi A; Sironi S
    Radiol Med; 2019 May; 124(5):350-359. PubMed ID: 30539411
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Technical Note: kV-independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction.
    Tao S; Sheedy E; Bruesewitz M; Weber N; Williams K; Halaweish A; Schmidt B; Williamson E; McCollough C; Leng S
    Med Phys; 2021 Mar; 48(3):1307-1314. PubMed ID: 33332626
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Automatic detection and quantification of the Agatston coronary artery calcium score on contrast computed tomography angiography.
    Ahmed W; de Graaf MA; Broersen A; Kitslaar PH; Oost E; Dijkstra J; Bax JJ; Reiber JH; Scholte AJ
    Int J Cardiovasc Imaging; 2015 Jan; 31(1):151-61. PubMed ID: 25159031
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.