213 related articles for article (PubMed ID: 34998443)
1. [Long-Term Results of Total Knee Replacement Using P.F.C. Sigma System with an All-Polyethylene Tibial Component].
Nachtnebl L; Tomáš T; Apostolopoulos V; Pazourek L; Mahdal M
Acta Chir Orthop Traumatol Cech; 2021; 88(6):412-417. PubMed ID: 34998443
[TBL] [Abstract][Full Text] [Related]
2. [Medin modular implant for total knee arthroplasty--mid-term results].
Vavrík P; Landor I; Tomaides J; Popelka S
Acta Chir Orthop Traumatol Cech; 2009 Feb; 76(1):30-4. PubMed ID: 19268046
[TBL] [Abstract][Full Text] [Related]
3. [Total knee arthroplasty with the Beznoska S.V.L. implant: short-term results].
Stárek M; Stehlík J; Held M
Acta Chir Orthop Traumatol Cech; 2004; 71(6):352-9. PubMed ID: 15686636
[TBL] [Abstract][Full Text] [Related]
4. Cemented all polyethylene tibial insert unicompartimental knee arthroplasty: a long term follow-up study.
Lustig S; Paillot JL; Servien E; Henry J; Ait Si Selmi T; Neyret P
Orthop Traumatol Surg Res; 2009 Feb; 95(1):12-21. PubMed ID: 19251232
[TBL] [Abstract][Full Text] [Related]
5. Uncemented Tantalum Monoblock Tibial Fixation for Total Knee Arthroplasty in Patients Less Than 60 Years of Age: Mean 10-Year Follow-up.
DeFrancesco CJ; Canseco JA; Nelson CL; Israelite CL; Kamath AF
J Bone Joint Surg Am; 2018 May; 100(10):865-870. PubMed ID: 29762282
[TBL] [Abstract][Full Text] [Related]
6. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.
Gudnason A; Hailer NP; W-Dahl A; Sundberg M; Robertsson O
J Bone Joint Surg Am; 2014 Jun; 96(12):994-999. PubMed ID: 24951734
[TBL] [Abstract][Full Text] [Related]
7. All-polyethylene versus metal-backed tibial component in total knee arthroplasty.
Longo UG; Ciuffreda M; D'Andrea V; Mannering N; Locher J; Denaro V
Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3620-3636. PubMed ID: 27209191
[TBL] [Abstract][Full Text] [Related]
8. Good survivorship of all-polyethylene tibial component UKA at long-term follow-up.
Bruni D; Gagliardi M; Akkawi I; Raspugli GF; Bignozzi S; Marko T; Bragonzoni L; Grassi A; Marcacci M
Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):182-7. PubMed ID: 25297704
[TBL] [Abstract][Full Text] [Related]
9. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design : five to eight-year follow-up.
O'Rourke MR; Callaghan JJ; Goetz DD; Sullivan PM; Johnston RC
J Bone Joint Surg Am; 2002 Aug; 84(8):1362-71. PubMed ID: 12177266
[TBL] [Abstract][Full Text] [Related]
10. Early to Midterm Clinical and Radiographic Survivorship of the All-Polyethylene Versus Modular Metal-Backed Tibia Component in Primary Total Knee Replacement.
Herschmiller T; Bradley KE; Wellman SS; Attarian DE
J Surg Orthop Adv; 2019; 28(2):108-114. PubMed ID: 31411955
[TBL] [Abstract][Full Text] [Related]
11. Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?
Schwarzkopf R; Scott RD; Carlson EM; Currier JH
Clin Orthop Relat Res; 2015 Jan; 473(1):220-5. PubMed ID: 24777725
[TBL] [Abstract][Full Text] [Related]
12. Monoblock all-polyethylene tibial components have a lower risk of early revision than metal-backed modular components.
Mohan V; Inacio MC; Namba RS; Sheth D; Paxton EW
Acta Orthop; 2013 Dec; 84(6):530-6. PubMed ID: 24237424
[TBL] [Abstract][Full Text] [Related]
13. Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis.
Houdek MT; Watts CD; Wyles CC; Martin JR; Trousdale RT; Taunton MJ
J Arthroplasty; 2017 Mar; 32(3):836-842. PubMed ID: 27816367
[TBL] [Abstract][Full Text] [Related]
14. [All-polyethylene tibial component in Walter-Motorlet total knee arthroplasty. Long-term outcomes].
Rybka V; Vavřík P; Landor I; Denk F; Hach J; Krůta T; Síbr M
Acta Chir Orthop Traumatol Cech; 2014; 81(2):122-8. PubMed ID: 25105786
[TBL] [Abstract][Full Text] [Related]
15. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.
Lachiewicz PF; Soileau ES
J Bone Joint Surg Am; 2004 Mar; 86(3):525-30. PubMed ID: 14996878
[TBL] [Abstract][Full Text] [Related]
16. [Revision knee arthroplasty due to aseptic loosening].
Rozkydal Z; Janík P; Janícek P; Kunovský R
Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):5-13. PubMed ID: 17331449
[TBL] [Abstract][Full Text] [Related]
17. Metal-Backed Tibial Components Do Not Reduce Risk of Early Aseptic Loosening in Unicompartmental Knee Arthroplasty: A Systematic Review and Meta-Analysis.
Costa GG; Lo Presti M; Grassi A; Agrò G; Cialdella S; Mosca M; Caravelli S; Zaffagnini S
J Knee Surg; 2020 Feb; 33(2):180-189. PubMed ID: 30650439
[TBL] [Abstract][Full Text] [Related]
18. Comparative Survivorship of Different Tibial Designs in Primary Total Knee Arthroplasty.
Kremers HM; Sierra RJ; Schleck CD; Berry DJ; Cabanela ME; Hanssen AD; Pagnano MW; Trousdale RT; Lewallen DG
J Bone Joint Surg Am; 2014 Jul; 96(14):e121. PubMed ID: 25031383
[TBL] [Abstract][Full Text] [Related]
19. All-Polyethylene Tibial Component Use for Elderly, Low-Demand Total Knee Arthroplasty Patients.
Gustke KA; Gelbke MK
J Arthroplasty; 2017 Aug; 32(8):2421-2426. PubMed ID: 28372918
[TBL] [Abstract][Full Text] [Related]
20. All-Polyethylene Tibial Components in Total Knee Replacement: Early Failures.
Alhifzi ZS; Khoja YT; Wood GC
J Knee Surg; 2019 Sep; 32(9):919-923. PubMed ID: 30282097
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]