These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 350026)

  • 1. [The transthoracic impedance method for the determination of the degree and change in extravascular water (author's transl)].
    Hull ET; Heemstra H; Wildevuur RH
    Acta Tuberc Pneumol Belg; 1977; 68(4):369-77. PubMed ID: 350026
    [No Abstract]   [Full Text] [Related]  

  • 2. [Transthoracic electrical impedance method for measurement of pulmonary edema in vivo (author's transl)].
    Ishibe Y
    Masui; 1978 Dec; 27(13):1559-67. PubMed ID: 731847
    [No Abstract]   [Full Text] [Related]  

  • 3. [Assessment of myocardial contractility by transthoracic impedance rheoplethysmography].
    Gurevich MI; Doloman LB; Dmitrieva AV
    Fiziol Zh (1978); 1988; 34(4):3-8. PubMed ID: 3181506
    [No Abstract]   [Full Text] [Related]  

  • 4. [Intraoperative changes in extravascular lung water. Study on heart surgery patients].
    Duma S; Aksakal D; Benzer W; Haider W; Krieger G; Polzer K; Schuhfried F
    Anaesthesist; 1985 Nov; 34(11):593-9. PubMed ID: 3911820
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Capacitoplethysmography--plethysmography by capacitance change detection (author's transl)].
    Kawakami K; Watanabe A; Ikeda K; Oshima M
    Iyodenshi To Seitai Kogaku; 1977 Oct; 15(6):410-5. PubMed ID: 604571
    [No Abstract]   [Full Text] [Related]  

  • 6. [Evaluation of extravascular lung fluid].
    Khorokhordin NE; Karmanov IV; Leosko VA; Shekhunov ED
    Fiziol Zh SSSR Im I M Sechenova; 1986 Aug; 72(8):1119-24. PubMed ID: 3758423
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Eligibility of limitations of electrical impedance plethysmography as a diagnostic means for disorders of pulmonary circulation (author's transl)].
    Ohta Y; Tsuji C; Shinozaki Y; Kuwahira I; Fuse M; Sugiyama Y
    Nihon Kyobu Shikkan Gakkai Zasshi; 1982 Jan; 20(1):38-45. PubMed ID: 7098162
    [No Abstract]   [Full Text] [Related]  

  • 8. Positive effects of prophylactic ventilator treatment on gas exchange and extravascular lung water in a porcine model of adult respiratory distress syndrome induced by endotoxaemia.
    Borg T; Modig J
    Acta Chir Scand; 1985; 151(6):501-8. PubMed ID: 3911696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Electrical impedance pneumography with a catheter electrode in the pulmonary artery--monitoring intrapulmonary water volume].
    Suzuki K
    Nihon Kyobu Geka Gakkai Zasshi; 1983 Dec; 31(12):2113-20. PubMed ID: 6674390
    [No Abstract]   [Full Text] [Related]  

  • 10. [Impedance plethysmography (author's transl)].
    Kira S; Ito A
    Kokyu To Junkan; 1974 Sep; 22(9):636-44. PubMed ID: 4614351
    [No Abstract]   [Full Text] [Related]  

  • 11. Changes in transthoracic electrical impedance during endotoxemia in dogs.
    Adamicza A; Tutsek L; Nagy S
    Acta Physiol Hung; 1997-1998; 85(4):291-302. PubMed ID: 10431600
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monitoring of lung edema using focused impedance spectroscopy: a feasibility study.
    Mayer M; Brunner P; Merwa R; Scharfetter H
    Physiol Meas; 2005 Jun; 26(3):185-92. PubMed ID: 15798294
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Extravascular lung water during acute respiratory distress syndrome in adult (author's transl)].
    Meignan M; George C; Lemaire F
    Bull Eur Physiopathol Respir; 1978; 14(6):617-28. PubMed ID: 753429
    [No Abstract]   [Full Text] [Related]  

  • 14. Assessment of acute pulmonary edema in dogs by electrical impedance imaging.
    Newell JC; Edic PM; Ren X; Larson-Wiseman JL; Danyleiko MD
    IEEE Trans Biomed Eng; 1996 Feb; 43(2):133-8. PubMed ID: 8682524
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Registration of the dynamics of acute pulmonary edema development by means of rheoplethysmography].
    Rusanov GA; Danilov EN; Petrash VV; Beliakov NA; Voinov VA
    Vestn Khir Im I I Grek; 1977 Sep; 119(9):38-43. PubMed ID: 919215
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A new method of pulmonary rheography in an experiment].
    Vaĭda RI; Gnatiuk MS; Gerasimiuk IE
    Fiziol Zh (1978); 1988; 34(4):109-11. PubMed ID: 3181502
    [No Abstract]   [Full Text] [Related]  

  • 17. [Possible use of double-frequency impedance measurements for determining total and extracellular fluid ratio in the body].
    Krotov VP; Bazunova EG; Kulaev BS
    Kosm Biol Aviakosm Med; 1985; 19(4):86-9. PubMed ID: 4057936
    [No Abstract]   [Full Text] [Related]  

  • 18. Measurement of pulmonary edema in intact dogs by transthoracic gamma-ray attenuation.
    Simon DS; Murray JF; Staub NC
    J Appl Physiol Respir Environ Exerc Physiol; 1979 Dec; 47(6):1228-33. PubMed ID: 536294
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement of left ventricular function with Minnesota impedance cardiograph (author's transl)].
    Matsuda Y; Yamada S; Sato H; Tomomatsu T
    Kokyu To Junkan; 1977 Mar; 25(3):241-6. PubMed ID: 557826
    [No Abstract]   [Full Text] [Related]  

  • 20. Effect on pulmonary capillary occlusion on extravascular lung water in pulmonary edema.
    Sugg JH; Karp RB; Kirklin JW
    Surg Forum; 1972; 23(0):216-8. PubMed ID: 4671080
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.