280 related articles for article (PubMed ID: 35013376)
1. Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder.
Ibrahim B; Jafari R
Sci Rep; 2022 Jan; 12(1):319. PubMed ID: 35013376
[TBL] [Abstract][Full Text] [Related]
2. Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept.
Ibrahim B; Jafari R
IEEE Trans Biomed Circuits Syst; 2019 Dec; 13(6):1723-1735. PubMed ID: 31603828
[TBL] [Abstract][Full Text] [Related]
3. Continuous Blood Pressure Monitoring using Wrist-worn Bio-impedance Sensors with Wet Electrodes.
Ibrahim B; Jafari R
IEEE Biomed Circuits Syst Conf; 2018 Oct; 2018():. PubMed ID: 31312808
[TBL] [Abstract][Full Text] [Related]
4. HGCTNet: Handcrafted Feature-Guided CNN and Transformer Network for Wearable Cuffless Blood Pressure Measurement.
Liu ZD; Li Y; Zhang YT; Zeng J; Chen ZX; Liu JK; Miao F
IEEE J Biomed Health Inform; 2024 Jul; 28(7):3882-3894. PubMed ID: 38687656
[TBL] [Abstract][Full Text] [Related]
5. Bi-Modal Arterial Compliance Probe for Calibration-Free Cuffless Blood Pressure Estimation.
P M N; Joseph J; Karthik S; Sivaprakasam M; Chenniappan M
IEEE Trans Biomed Eng; 2018 Nov; 65(11):2392-2404. PubMed ID: 30130174
[TBL] [Abstract][Full Text] [Related]
6. Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography.
Huynh TH; Jafari R; Chung WY
IEEE Trans Biomed Eng; 2019 Apr; 66(4):967-976. PubMed ID: 30130167
[TBL] [Abstract][Full Text] [Related]
7. Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study.
Islam SMS; Cartledge S; Karmakar C; Rawstorn JC; Fraser SF; Chow C; Maddison R
JMIR Mhealth Uhealth; 2019 Sep; 7(10):e14706. PubMed ID: 31628788
[TBL] [Abstract][Full Text] [Related]
8. Design and validation of dual-point time-differentiated photoplethysmogram (2PPG) wearable for cuffless blood pressure estimation.
Wong KFM; Huang W; Ee DYH; Ng EYK
Comput Methods Programs Biomed; 2024 Aug; 253():108251. PubMed ID: 38824806
[TBL] [Abstract][Full Text] [Related]
9. Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations.
Joung J; Jung CW; Lee HC; Chae MJ; Kim HS; Park J; Shin WY; Kim C; Lee M; Choi C
Sci Rep; 2023 May; 13(1):8605. PubMed ID: 37244974
[TBL] [Abstract][Full Text] [Related]
10. CiGNN: A Causality-Informed and Graph Neural Network Based Framework for Cuffless Continuous Blood Pressure Estimation.
Liu L; Lu H; Whelan M; Chen Y; Ding X
IEEE J Biomed Health Inform; 2024 May; 28(5):2674-2686. PubMed ID: 38478458
[TBL] [Abstract][Full Text] [Related]
11. Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique.
Nabeel PM; Jayaraj J; Mohanasankar S
Physiol Meas; 2017 Nov; 38(12):2122-2140. PubMed ID: 29058686
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.
Mukkamala R; Yavarimanesh M; Natarajan K; Hahn JO; Kyriakoulis KG; Avolio AP; Stergiou GS
Hypertension; 2021 Nov; 78(5):1161-1167. PubMed ID: 34510915
[TBL] [Abstract][Full Text] [Related]
13. Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring.
Kachuee M; Kiani MM; Mohammadzade H; Shabany M
IEEE Trans Biomed Eng; 2017 Apr; 64(4):859-869. PubMed ID: 27323356
[TBL] [Abstract][Full Text] [Related]
14. Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System.
Rachim VP; Chung WY
Sci Rep; 2019 May; 9(1):7947. PubMed ID: 31138845
[TBL] [Abstract][Full Text] [Related]
15. Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement.
Wang TW; Lin SF
Sensors (Basel); 2020 Feb; 20(3):. PubMed ID: 32033495
[TBL] [Abstract][Full Text] [Related]
16. Multi-source Multi-frequency Bio-impedance Measurement Method for Localized Pulse Wave Monitoring.
Ibrahim B; Talukder A; Jafari R
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():3945-3948. PubMed ID: 33018863
[TBL] [Abstract][Full Text] [Related]
17. Real-time Signal-to-Noise Ratio Optimization of Bio-Impedance Signal for Cuffless Blood Pressure Monitoring.
Passage B; Ibrahim B; Jafari R
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7480-7484. PubMed ID: 34892823
[TBL] [Abstract][Full Text] [Related]
18. Clinical Validation of a Wearable Piezoelectric Blood-Pressure Sensor for Continuous Health Monitoring.
Min S; Kim DH; Joe DJ; Kim BW; Jung YH; Lee JH; Lee BY; Doh I; An J; Youn YN; Joung B; Yoo CD; Ahn HS; Lee KJ
Adv Mater; 2023 Jun; 35(26):e2301627. PubMed ID: 36960816
[TBL] [Abstract][Full Text] [Related]
19. Enabling Wearable Pulse Transit Time-Based Blood Pressure Estimation for Medically Underserved Areas and Health Equity: Comprehensive Evaluation Study.
Ganti V; Carek AM; Jung H; Srivatsa AV; Cherry D; Johnson LN; Inan OT
JMIR Mhealth Uhealth; 2021 Aug; 9(8):e27466. PubMed ID: 34338646
[TBL] [Abstract][Full Text] [Related]
20. Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor.
McCombie DB; Reisner AT; Asada HH
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():989-92. PubMed ID: 19162824
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]