These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Measuring nanometre-scale electric fields in scanning transmission electron microscopy using segmented detectors. Brown HG; Shibata N; Sasaki H; Petersen TC; Paganin DM; Morgan MJ; Findlay SD Ultramicroscopy; 2017 Nov; 182():169-178. PubMed ID: 28692934 [TBL] [Abstract][Full Text] [Related]
4. Ultra-high contrast STEM imaging for segmented/pixelated detectors by maximizing the signal-to-noise ratio. Ooe K; Seki T; Ikuhara Y; Shibata N Ultramicroscopy; 2021 Jan; 220():113133. PubMed ID: 33181363 [TBL] [Abstract][Full Text] [Related]
5. Efficient phase contrast imaging in STEM using a pixelated detector. Part II: optimisation of imaging conditions. Yang H; Pennycook TJ; Nellist PD Ultramicroscopy; 2015 Apr; 151():232-239. PubMed ID: 25481091 [TBL] [Abstract][Full Text] [Related]
6. Coherent Diffraction Imaging in Transmission Electron Microscopy for Atomic Resolution Quantitative Studies of the Matter. Carlino E; Scattarella F; Caro L; Giannini C; Siliqi D; Colombo A; Galli DE Materials (Basel); 2018 Nov; 11(11):. PubMed ID: 30463217 [TBL] [Abstract][Full Text] [Related]
7. Optimized detector configurations for the reconstruction of phase-contrast images in scanning transmission electron microscopy. Oster A; Kohl H Ultramicroscopy; 2023 Apr; 246():113670. PubMed ID: 36657215 [TBL] [Abstract][Full Text] [Related]
8. Towards quantitative, atomic-resolution reconstruction of the electrostatic potential via differential phase contrast using electrons. Close R; Chen Z; Shibata N; Findlay SD Ultramicroscopy; 2015 Dec; 159 Pt 1():124-37. PubMed ID: 26381331 [TBL] [Abstract][Full Text] [Related]
9. Electron ptychographic phase imaging of light elements in crystalline materials using Wigner distribution deconvolution. Yang H; MacLaren I; Jones L; Martinez GT; Simson M; Huth M; Ryll H; Soltau H; Sagawa R; Kondo Y; Ophus C; Ercius P; Jin L; Kovács A; Nellist PD Ultramicroscopy; 2017 Sep; 180():173-179. PubMed ID: 28434783 [TBL] [Abstract][Full Text] [Related]
11. Direct Visualization of Local Electromagnetic Field Structures by Scanning Transmission Electron Microscopy. Shibata N; Findlay SD; Matsumoto T; Kohno Y; Seki T; Sánchez-Santolino G; Ikuhara Y Acc Chem Res; 2017 Jul; 50(7):1502-1512. PubMed ID: 28677953 [TBL] [Abstract][Full Text] [Related]
12. Low magnification differential phase contrast imaging of electric fields in crystals with fine electron probes. Taplin DJ; Shibata N; Weyland M; Findlay SD Ultramicroscopy; 2016 Oct; 169():69-79. PubMed ID: 27449276 [TBL] [Abstract][Full Text] [Related]
13. Atom-by-atom chemical identification from scanning transmission electron microscopy images in presence of noise and residual aberrations. Hofer C; Skákalová V; Haas J; Wang X; Braun K; Pennington RS; Meyer JC Ultramicroscopy; 2021 Aug; 227():113292. PubMed ID: 33992503 [TBL] [Abstract][Full Text] [Related]
14. Simultaneous atomic-resolution electron ptychography and Z-contrast imaging of light and heavy elements in complex nanostructures. Yang H; Rutte RN; Jones L; Simson M; Sagawa R; Ryll H; Huth M; Pennycook TJ; Green ML; Soltau H; Kondo Y; Davis BG; Nellist PD Nat Commun; 2016 Aug; 7():12532. PubMed ID: 27561914 [TBL] [Abstract][Full Text] [Related]
15. Practical aspects of diffractive imaging using an atomic-scale coherent electron probe. Chen Z; Weyland M; Ercius P; Ciston J; Zheng C; Fuhrer MS; D'Alfonso AJ; Allen LJ; Findlay SD Ultramicroscopy; 2016 Oct; 169():107-121. PubMed ID: 27517162 [TBL] [Abstract][Full Text] [Related]
16. Development of tilt-scan system for differential phase contrast scanning transmission electron microscopy. Kohno Y; Nakamura A; Morishita S; Shibata N Microscopy (Oxf); 2022 Apr; 71(2):111-116. PubMed ID: 35032164 [TBL] [Abstract][Full Text] [Related]
17. Phase imaging in scanning transmission electron microscopy using bright-field balanced divergency method. Wang B; McComb DW Ultramicroscopy; 2023 Mar; 245():113665. PubMed ID: 36571903 [TBL] [Abstract][Full Text] [Related]
18. A new method to detect and correct sample tilt in scanning transmission electron microscopy bright-field imaging. Brown HG; Ishikawa R; Sánchez-Santolino G; Lugg NR; Ikuhara Y; Allen LJ; Shibata N Ultramicroscopy; 2017 Feb; 173():76-83. PubMed ID: 27987470 [TBL] [Abstract][Full Text] [Related]
19. Efficient phase contrast imaging in STEM using a pixelated detector. Part 1: experimental demonstration at atomic resolution. Pennycook TJ; Lupini AR; Yang H; Murfitt MF; Jones L; Nellist PD Ultramicroscopy; 2015 Apr; 151():160-167. PubMed ID: 25458189 [TBL] [Abstract][Full Text] [Related]
20. Measurement of atomic electric fields and charge densities from average momentum transfers using scanning transmission electron microscopy. Müller-Caspary K; Krause FF; Grieb T; Löffler S; Schowalter M; Béché A; Galioit V; Marquardt D; Zweck J; Schattschneider P; Verbeeck J; Rosenauer A Ultramicroscopy; 2017 Jul; 178():62-80. PubMed ID: 27217350 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]