130 related articles for article (PubMed ID: 35021487)
1. Recombinant Spider Silk and Collagen-Based Nerve Guidance Conduits Support Neuronal Cell Differentiation and Functionality in Vitro.
Pawar K; Welzel G; Haynl C; Schuster S; Scheibel T
ACS Appl Bio Mater; 2019 Nov; 2(11):4872-4880. PubMed ID: 35021487
[TBL] [Abstract][Full Text] [Related]
2. Nerve guidance conduit design based on self-rolling tubes.
Aigner TB; Haynl C; Salehi S; O'Connor A; Scheibel T
Mater Today Bio; 2020 Jan; 5():100042. PubMed ID: 32159159
[TBL] [Abstract][Full Text] [Related]
3. A New Preparation Method for Anisotropic Silk Fibroin Nerve Guidance Conduits and Its Evaluation In Vitro and in a Rat Sciatic Nerve Defect Model.
Teuschl AH; Schuh C; Halbweis R; Pajer K; Márton G; Hopf R; Mosia S; Rünzler D; Redl H; Nógrádi A; Hausner T
Tissue Eng Part C Methods; 2015 Sep; 21(9):945-57. PubMed ID: 25819471
[TBL] [Abstract][Full Text] [Related]
4. Artificial spider silk supports and guides neurite extension in vitro.
Hansson ML; Chatterjee U; Francis J; Arndt T; Broman C; Johansson J; Sköld MK; Rising A
FASEB J; 2021 Nov; 35(11):e21896. PubMed ID: 34634154
[TBL] [Abstract][Full Text] [Related]
5. Defining the regenerative effects of native spider silk fibers on primary Schwann cells, sensory neurons, and nerve-associated fibroblasts.
Millesi F; Weiss T; Mann A; Haertinger M; Semmler L; Supper P; Pils D; Naghilou A; Radtke C
FASEB J; 2021 Feb; 35(2):e21196. PubMed ID: 33210360
[TBL] [Abstract][Full Text] [Related]
6. Porous nerve guidance conduits reinforced with braided composite structures of silk/magnesium filaments for peripheral nerve repair.
Zhang S; Wang J; Zheng Z; Yan J; Zhang L; Li Y; Zhang J; Li G; Wang X; Kaplan D
Acta Biomater; 2021 Oct; 134():116-130. PubMed ID: 34289421
[TBL] [Abstract][Full Text] [Related]
7. Spider silk as guiding biomaterial for human model neurons.
Roloff F; Strauß S; Vogt PM; Bicker G; Radtke C
Biomed Res Int; 2014; 2014():906819. PubMed ID: 24949480
[TBL] [Abstract][Full Text] [Related]
8. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.
Chang W; Shah MB; Lee P; Yu X
Acta Biomater; 2018 Jun; 73():302-311. PubMed ID: 29702292
[TBL] [Abstract][Full Text] [Related]
9. Correlating the secondary protein structure of natural spider silk with its guiding properties for Schwann cells.
Naghilou A; Pöttschacher L; Millesi F; Mann A; Supper P; Semmler L; Weiss T; Backus EHG; Radtke C
Mater Sci Eng C Mater Biol Appl; 2020 Nov; 116():111219. PubMed ID: 32806225
[TBL] [Abstract][Full Text] [Related]
10. Spider silk nerve graft promotes axonal regeneration on long distance nerve defect in a sheep model.
Kornfeld T; Nessler J; Helmer C; Hannemann R; Waldmann KH; Peck CT; Hoffmann P; Brandes G; Vogt PM; Radtke C
Biomaterials; 2021 Apr; 271():120692. PubMed ID: 33607544
[TBL] [Abstract][Full Text] [Related]
11. Regenerative potential of silk conduits in repair of peripheral nerve injury in adult rats.
Huang W; Begum R; Barber T; Ibba V; Tee NC; Hussain M; Arastoo M; Yang Q; Robson LG; Lesage S; Gheysens T; Skaer NJ; Knight DP; Priestley JV
Biomaterials; 2012 Jan; 33(1):59-71. PubMed ID: 22005069
[TBL] [Abstract][Full Text] [Related]
12. Characterization and Schwann Cell Seeding of up to 15.0 cm Long Spider Silk Nerve Conduits for Reconstruction of Peripheral Nerve Defects.
Kornfeld T; Vogt PM; Bucan V; Peck CT; Reimers K; Radtke C
J Funct Biomater; 2016 Nov; 7(4):. PubMed ID: 27916868
[TBL] [Abstract][Full Text] [Related]
13. Electrospun and woven silk fibroin/poly(lactic-co-glycolic acid) nerve guidance conduits for repairing peripheral nerve injury.
Wang YL; Gu XM; Kong Y; Feng QL; Yang YM
Neural Regen Res; 2015 Oct; 10(10):1635-42. PubMed ID: 26692862
[TBL] [Abstract][Full Text] [Related]
14. In vitro efficacy of a gene-activated nerve guidance conduit incorporating non-viral PEI-pDNA nanoparticles carrying genes encoding for NGF, GDNF and c-Jun.
Lackington WA; Raftery RM; O'Brien FJ
Acta Biomater; 2018 Jul; 75():115-128. PubMed ID: 29885855
[TBL] [Abstract][Full Text] [Related]
15. The Use of Genipin as an Effective, Biocompatible, Anti-Inflammatory Cross-Linking Method for Nerve Guidance Conduits.
Kočí Z; Sridharan R; Hibbitts AJ; Kneafsey SL; Kearney CJ; O'Brien FJ
Adv Biosyst; 2020 Mar; 4(3):e1900212. PubMed ID: 32293152
[TBL] [Abstract][Full Text] [Related]
16. Nanofibrous nerve guidance conduits decorated with decellularized matrix hydrogel facilitate peripheral nerve injury repair.
Zheng C; Yang Z; Chen S; Zhang F; Rao Z; Zhao C; Quan D; Bai Y; Shen J
Theranostics; 2021; 11(6):2917-2931. PubMed ID: 33456580
[No Abstract] [Full Text] [Related]
17. Augmented peripheral nerve regeneration through elastic nerve guidance conduits prepared using a porous PLCL membrane with a 3D printed collagen hydrogel.
Yoo J; Park JH; Kwon YW; Chung JJ; Choi IC; Nam JJ; Lee HS; Jeon EY; Lee K; Kim SH; Jung Y; Park JW
Biomater Sci; 2020 Nov; 8(22):6261-6271. PubMed ID: 33016275
[TBL] [Abstract][Full Text] [Related]
18. In vivo studies of silk based gold nano-composite conduits for functional peripheral nerve regeneration.
Das S; Sharma M; Saharia D; Sarma KK; Sarma MG; Borthakur BB; Bora U
Biomaterials; 2015 Sep; 62():66-75. PubMed ID: 26026910
[TBL] [Abstract][Full Text] [Related]
19. Use of spider silk fibres as an innovative material in a biocompatible artificial nerve conduit.
Allmeling C; Jokuszies A; Reimers K; Kall S; Vogt PM
J Cell Mol Med; 2006; 10(3):770-7. PubMed ID: 16989736
[TBL] [Abstract][Full Text] [Related]
20. Multichannel Bioactive Silk Nanofiber Conduits Direct and Enhance Axonal Regeneration after Spinal Cord Injury.
You R; Zhang Q; Li X; Yan S; Luo Z; Qu J; Li M
ACS Biomater Sci Eng; 2020 Aug; 6(8):4677-4686. PubMed ID: 33455191
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]