These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 35033984)

  • 41. Finite element modeling for development and optimization of a bone plate for mandibular fracture in dogs.
    Freitas EP; Rahal SC; Gioso MA; Vulcano LC; Shimano AC; da Silva JV; Noritomi PY; El Warrak AO
    J Vet Dent; 2010; 27(4):212-21. PubMed ID: 21322428
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Finite Element Evaluation of Different Osteosynthesis Variations That Used After Segmental Mandibular Resection.
    Şanal KO; Özden B; Baş B
    J Craniofac Surg; 2017 Jan; 28(1):61-65. PubMed ID: 27893561
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparison of the risk of breakage of two kinds of sacroiliac screws in the treatment of bilateral sacral fractures.
    Fu S; Zhao Y; Lian W; Zou D; Sun T; Zhao Y; Tan J; Zhang S; Wang D
    Eur Spine J; 2014 Jul; 23(7):1558-67. PubMed ID: 24770589
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle.
    Aquilina P; Chamoli U; Parr WC; Clausen PD; Wroe S
    Br J Oral Maxillofac Surg; 2013 Jun; 51(4):326-31. PubMed ID: 22981343
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Three-dimensional finite element analysis of traumatic mechanism of mandibular symphyseal fracture combined with bilateral intracapsular condylar fractures].
    Zhou W; An JG; Rong QG; Zhang Y
    Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 53(5):983-989. PubMed ID: 34650306
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Biomechanical Comparison of Titanium and Poly- L -Lactic Acid Trapezoidal Plates Applied in a Subcondylar Fracture Model.
    Keskin Yalcin B
    J Craniofac Surg; 2023 Sep; 34(6):1737-1740. PubMed ID: 36856431
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Finite element analysis of 3D-printed personalized titanium plates for mandibular angle fracture.
    Li Y; Li H; Lai Q; Xue R; Zhu K; Deng Y
    Comput Methods Biomech Biomed Engin; 2023 Jan; 26(1):78-89. PubMed ID: 35587215
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Evaluation of internal fixation techniques for extracapsular fracture: A finite element analysis and comparison.
    Bu L; Wei X; Zheng J; Qiu Y; Yang C
    Comput Methods Programs Biomed; 2022 Oct; 225():107072. PubMed ID: 36037603
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Finite Element Analysis of Insertion Angle of Absorbable Screws for the Fixation of Radial Head Fractures.
    Xu GM; Liang ZY; Li W; Yang ZZ; Chen ZB; Zhang J
    Orthop Surg; 2020 Dec; 12(6):1710-1717. PubMed ID: 33000562
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Computational Biomechanical Analysis of Postoperative Calcaneal Fractures with Different Placement of the Sustentaculum Screw.
    Qiang MF; Singh RK; Chen YX; Zhang K; Jia XY; Chen S; Wang SG; Wang X; Shi ZM
    Orthop Surg; 2020 Apr; 12(2):661-667. PubMed ID: 32053281
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Finite element analysis of titanium anatomic plate and titanium reconstructive plate for treatment of extra-articular fractures of the scapula.
    Shang Y; Bi Y; Cao Y; Wang Y
    J Orthop Surg Res; 2023 Feb; 18(1):134. PubMed ID: 36823648
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture.
    Wang T; Zhao B; Yan J; Shao B; Mu W
    Int Orthop; 2022 Mar; 46(3):623-634. PubMed ID: 34981159
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A new 3-dimensional plate for transoral endoscopic-assisted osteosynthesis of condylar neck fractures.
    Lauer G; Pradel W; Schneider M; Eckelt U
    J Oral Maxillofac Surg; 2007 May; 65(5):964-71. PubMed ID: 17448849
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
    Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
    Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures.
    Cox T; Kohn MW; Impelluso T
    J Oral Maxillofac Surg; 2003 Apr; 61(4):481-7; discussion 487-8. PubMed ID: 12684967
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Titanium alloy cannulated screws and biodegrade ceramic nails for treatment of femoral neck fractures: A finite element analysis.
    Liu Y; Ren Z; Shao H; Wang X; Ma Y; Song W; Wu X; Zhang X; Li P; He Y; Wei X; Duan W
    Injury; 2023 Aug; 54(8):110841. PubMed ID: 37316405
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Application of the lambda plate on condylar fractures: Finite element evaluation of the fixation rigidity for different fracture patterns and plate placements.
    Liokatis P; Tzortzinis G; Gerasimidis S; Smolka W
    Injury; 2022 Apr; 53(4):1345-1352. PubMed ID: 35101256
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Parameter optimization in a finite element mandibular fracture fixation model using the design of experiments approach.
    Maintz M; Msallem B; de Wild M; Seiler D; Herrmann S; Feiler S; Sharma N; Dalcanale F; Cattin P; Thieringer FM
    J Mech Behav Biomed Mater; 2023 Aug; 144():105948. PubMed ID: 37348171
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis.
    Zhang RY; Li JT; Zhao JX; Zhao Z; Zhang LC; Yun C; Su XY; Tang PF
    Injury; 2022 Feb; 53(2):353-361. PubMed ID: 34801246
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Treatment of thoracolumbar fracture with pedicle screws at injury level: a biomechanical study based on three-dimensional finite element analysis.
    Li QL; Li XZ; Liu Y; Zhang HS; Shang P; Chu ZM; Chen JC; Chen M; Qin R
    Eur J Orthop Surg Traumatol; 2013 Oct; 23(7):775-80. PubMed ID: 23412208
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.