145 related articles for article (PubMed ID: 35035823)
21. The sensitivity of 24 h Holter monitoring and exercise testing for the recognition of myocardial ischaemia: a comparative study.
Günther H; Osterspey A; Treis-Müller I; Eggeling T; Höpp HW; Hilger HH
Eur Heart J; 1988 Dec; 9 Suppl N():46-9. PubMed ID: 3246256
[TBL] [Abstract][Full Text] [Related]
22. [The electrocardiogram during physical stress and Holter monitoring in the detection of asymptomatic myocardial infarct].
Damjanović MM
Srp Arh Celok Lek; 1997; 125(11-12):340-4. PubMed ID: 9480567
[TBL] [Abstract][Full Text] [Related]
23. The cardiac diagnostic work-up in stroke patients-A subanalysis of the Find-AFRANDOMISED trial.
Wasser K; Weber-Krüger M; Jürries F; Liman J; Hamann GF; Kermer P; Uphaus T; Protsenko E; Seegers J; Mende M; Gröschel K; Wachter R
PLoS One; 2019; 14(5):e0216530. PubMed ID: 31071137
[TBL] [Abstract][Full Text] [Related]
24. Comparison of ST depression recorded by Holter monitors and 12-lead ECGs during coronary angiography and exercise testing.
Sharp SD; Mason JW; Bray B
J Electrocardiol; 1992 Oct; 25(4):323-31. PubMed ID: 1402518
[TBL] [Abstract][Full Text] [Related]
25. [Cost-effect clinical analysis in choice of methods of coronary heart disease diagnosis].
Kalashnikov VIu; Mitriagina SN; Syrkin AL; Poltavskaia MG
Ter Arkh; 2008; 80(4):8-11. PubMed ID: 18491572
[TBL] [Abstract][Full Text] [Related]
26. Identifying arrhythmias in adults with congenital heart disease by 24-h ambulatory electrocardiography.
Rodriguez FH; Moodie DS; Neeland M; Adams GJ; Snyder CS
Pediatr Cardiol; 2012 Apr; 33(4):591-5. PubMed ID: 22318853
[TBL] [Abstract][Full Text] [Related]
27. Utility of 12-lead and signal-averaged Holter electrocardiograms after pilsicainide provocation for risk stratification in Brugada syndrome.
Kakihara J; Takagi M; Hayashi Y; Tatsumi H; Doi A; Yoshiyama M
Heart Vessels; 2017 Sep; 32(9):1151-1159. PubMed ID: 28364267
[TBL] [Abstract][Full Text] [Related]
28. [Value of cycloergometer and dynamic ECG (Holter ) in the diagnosis of coronary insufficiency (author's transl)].
Baccichetto R; Baldantoni E; Borelli D; Fachechi C; Lusiani L; Pigato R; Pagnan A; Dal Palù C
G Ital Cardiol; 1980; 10(7):870-6. PubMed ID: 7461335
[TBL] [Abstract][Full Text] [Related]
29. QRS morphologies of the surface ECG of nonsustained ventricular tachycardias during holter monitoring compared with QRS morphologies of spontaneous sustained ventricular tachycardias.
Weismüller P; Mutter K; Kochs M; Osterhues H; Grossmann G; Hombach V
J Electrocardiol; 1996 Jan; 29(1):27-31. PubMed ID: 8808522
[TBL] [Abstract][Full Text] [Related]
30. The inverse Nehb J lead increases the sensitivity of Holter electrocardiographic monitoring for detecting myocardial ischemia.
Seeberger MD; Moerlen J; Skarvan K; Friedli D; Vankova S; Buser P; Pfisterer M
Am J Cardiol; 1997 Jul; 80(1):1-5. PubMed ID: 9205010
[TBL] [Abstract][Full Text] [Related]
31. Comparison of the patient-activated event recording system vs. traditional 24 h Holter electrocardiography in individuals with paroxysmal palpitations or dizziness.
de Asmundis C; Conte G; Sieira J; Chierchia GB; Rodriguez-Manero M; Di Giovanni G; Ciconte G; Levinstein M; Baltogiannis G; Saitoh Y; Casado-Arroyo R; Brugada P
Europace; 2014 Aug; 16(8):1231-5. PubMed ID: 24574492
[TBL] [Abstract][Full Text] [Related]
32. Evaluation of a Holter system to record ST-segment changes.
Hammill SC
J Electrocardiol; 1987 Oct; 20 Suppl():12-5. PubMed ID: 3694091
[TBL] [Abstract][Full Text] [Related]
33. 12-lead Holter monitoring in diving and water sports: a preliminary investigation.
Bosco G; De Marzi E; Michieli P; Omar HR; Camporesi EM; Padulo J; Paoli A; Mangar D; Schiavon M
Diving Hyperb Med; 2014 Dec; 44(4):202-7. PubMed ID: 25596833
[TBL] [Abstract][Full Text] [Related]
34. Comparing the consistency of electrocardiogram interval measurements by resting ECG versus 12-lead Holter.
Mendzelevski B; Spencer CS; Freier A; Camilleri D; Graff C; Täubel J
Ann Noninvasive Electrocardiol; 2021 Sep; 26(5):e12851. PubMed ID: 33949017
[TBL] [Abstract][Full Text] [Related]
35. The evolution of ambulatory ECG monitoring.
Kennedy HL
Prog Cardiovasc Dis; 2013; 56(2):127-32. PubMed ID: 24215744
[TBL] [Abstract][Full Text] [Related]
36. [Implementation of Wearable Terminal Used for Dynamic ECG Real-time Monitoring Based on Internet of Things].
Tang M; Yao J; Chen Z; Huang H; Geng C
Zhongguo Yi Liao Qi Xie Za Zhi; 2018 May; 42(3):161-165. PubMed ID: 29885118
[TBL] [Abstract][Full Text] [Related]
37. Holter recording during treadmill testing in assessing myocardial ischemic changes.
Tzivoni D; Benhorin J; Gavish A; Stern S
Am J Cardiol; 1985 Apr; 55(9):1200-3. PubMed ID: 3984900
[TBL] [Abstract][Full Text] [Related]
38. Automatic Mobile Health Arrhythmia Monitoring for the Detection of Atrial Fibrillation: Prospective Feasibility, Accuracy, and User Experience Study.
Santala OE; Halonen J; Martikainen S; Jäntti H; Rissanen TT; Tarvainen MP; Laitinen TP; Laitinen TM; Väliaho ES; Hartikainen JEK; Martikainen TJ; Lipponen JA
JMIR Mhealth Uhealth; 2021 Oct; 9(10):e29933. PubMed ID: 34677135
[TBL] [Abstract][Full Text] [Related]
39. Prolonged ECG with a novel recorder utilizing electrode belt and mobile device in patients with recent embolic stroke of undetermined source: A pilot study.
Lumikari TJ; Pirinen J; Putaala J; Sibolt G; Kerola A; Pakarinen S; Lehto M; Nieminen T
Ann Noninvasive Electrocardiol; 2020 Nov; 25(6):e12802. PubMed ID: 32981209
[TBL] [Abstract][Full Text] [Related]
40. Evaluation of cardiac autonomic nervous system in patients with ankylosing spondylitis using 12-lead electrocardiography and Holter monitoring.
Candemir M; Candemir B; Ertürk A
Clin Rheumatol; 2020 Sep; 39(9):2631-2639. PubMed ID: 32212003
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]