These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 35044380)

  • 1. Development and comparison of various rod-shaped mini-reference electrode compositions based on Ag/AgCl for potentiometric applications.
    Nigde M; Agir I; Yıldırım R; Isildak I
    Analyst; 2022 Jan; 147(3):516-526. PubMed ID: 35044380
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor.
    Liao WY; Chou TC
    Anal Chem; 2006 Jun; 78(12):4219-23. PubMed ID: 16771553
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multielectrode Arrays at Wafer-Level for Miniaturized Sensors Applications: Electrochemical Growth of Ag/AgCl Reference Electrodes.
    Wu H; Krause R; Gogoi E; Reck A; Graf A; Wislicenus M; Hild OR; Guhl C
    Sensors (Basel); 2023 Jul; 23(13):. PubMed ID: 37447979
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Leakless, Bipolar Reference Electrodes: Fabrication, Performance, and Miniaturization.
    Walker NL; Dick JE
    Anal Chem; 2021 Jul; 93(29):10065-10074. PubMed ID: 34263595
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fabrication and characterisation of the graphene ring micro electrode (GRiME) with an integrated, concentric Ag/AgCl reference electrode.
    Dickinson JW; Bromley M; Andrieux FP; Boxall C
    Sensors (Basel); 2013 Mar; 13(3):3635-51. PubMed ID: 23493126
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A solid-state thin-film Ag/AgCl reference electrode coated with graphene oxide and its use in a pH sensor.
    Kim TY; Hong SA; Yang S
    Sensors (Basel); 2015 Mar; 15(3):6469-82. PubMed ID: 25789490
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel chloride selective potentiometric sensor based on graphitic carbon nitride/silver chloride (g-C
    Alizadeh T; Rafiei F; Akhoundian M
    Talanta; 2022 Jan; 237():122895. PubMed ID: 34736711
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel Flexible Ag/AgCl Quasi-Reference Electrode with Fishbone Nanowire Structure for Remarkable Potential Stability, Long-Term Reliability, and Noninvasive Electrocardiography.
    Tian W; Cao H; Zhang Y; Na Z; Hui Y; Jin Z; Lang MF; Li Y; Sun J
    Anal Chem; 2023 Jan; 95(4):2413-2419. PubMed ID: 36633558
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a Disposable Polyacrylamide Hydrogel-Based Semipermeable Membrane for Micro Ag/AgCl Reference Electrode.
    Andriukonis E; Butkevicius M; Simonis P; Ramanavicius A
    Sensors (Basel); 2023 Feb; 23(5):. PubMed ID: 36904713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A flexible Ag/AgCl micro reference electrode based on a parylene tube structure.
    Zhao Z; Tu H; Kim EG; Sloane BF; Xu Y
    Sens Actuators B Chem; 2017 Aug; 247():92-97. PubMed ID: 28970651
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Textile-Based Potentiometric Electrochemical pH Sensor for Wearable Applications.
    Manjakkal L; Dang W; Yogeswaran N; Dahiya R
    Biosensors (Basel); 2019 Jan; 9(1):. PubMed ID: 30654478
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Symmetric cell for improving solid-contact pH electrodes.
    Zdrachek E; Forrest T; Bakker E
    Anal Chim Acta; 2023 Jan; 1239():340652. PubMed ID: 36628749
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microporous Ag/AgCl on a Titanium Scaffold for Use in Capillary Reference Electrodes.
    Robinson EEA; Troudt BK; Bühlmann P
    Anal Chem; 2024 Feb; 96(5):2236-2243. PubMed ID: 38277487
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Graphite/Ag/AgCl nanocomposite as a new and highly efficient electrocatalyst for selective electroxidation of oxalic acid and its assay in real samples.
    Alizadeh T; Nayeri S
    Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():826-836. PubMed ID: 30948120
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Pt layer/Pt disk electrode configuration to evaluate respiration and alkaline phosphatase activities of mouse embryoid bodies.
    Obregon R; Horiguchi Y; Arai T; Abe S; Zhou Y; RyosukeTakahashi ; Hisada A; Ino K; Shiku H; Matsue T
    Talanta; 2012 May; 94():30-5. PubMed ID: 22608410
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-analyte biochip (MAB) based on all-solid-state ion-selective electrodes (ASSISE) for physiological research.
    Wan Salim WW; Zeitchek MA; Hermann AC; Ricco AJ; Tan M; Selch F; Fleming E; Bebout BM; Bader MM; Ul Haque A; Porterfield DM
    J Vis Exp; 2013 Apr; (74):. PubMed ID: 23628944
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Potentiometric responses of ion-selective microelectrode with bovine serum albumin adsorption.
    Goda T; Yamada E; Katayama Y; Tabata M; Matsumoto A; Miyahara Y
    Biosens Bioelectron; 2016 Mar; 77():208-14. PubMed ID: 26409020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improvement of the silver/silver chloride reference electrode and its application to pH measurement.
    Ito S; Hachiya H; Baba K; Asano Y; Wada H
    Talanta; 1995 Nov; 42(11):1685-90. PubMed ID: 18966402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An all-solid-state reference electrode based on the layer-by-layer polymer coating.
    Kwon NH; Lee KS; Won MS; Shim YB
    Analyst; 2007 Sep; 132(9):906-12. PubMed ID: 17710266
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dynamic Electrochemical Measurement of Chloride Ions.
    Abbas Y; de Graaf DB; Olthuis W; van den Berg A
    J Vis Exp; 2016 Feb; (108):e53312. PubMed ID: 26889572
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.