These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 35045842)

  • 21. A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component.
    Post CE; Bitter T; Briscoe A; Verdonschot N; Janssen D
    J Biomech; 2022 May; 137():111057. PubMed ID: 35462265
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Study and numerical analysis of Von Mises stress of a new tumor-type distal femoral prosthesis comprising a peek composite reinforced with carbon fibers: finite element analysis.
    Guo Y; Guo W
    Comput Methods Biomech Biomed Engin; 2022 Nov; 25(15):1663-1677. PubMed ID: 35094629
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The evaluation of artificial talus implant on ankle joint contact characteristics: a finite element study based on four subjects.
    Liu T; Jomha N; Adeeb S; El-Rich M; Westover L
    Med Biol Eng Comput; 2022 Apr; 60(4):1139-1158. PubMed ID: 35237925
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of carbon-fiber-reinforced polyetheretherketone on stress distribution in a redesigned tumor-type knee prosthesis: a finite element analysis.
    Wu H; Guo Y; Guo W
    Front Bioeng Biotechnol; 2023; 11():1243936. PubMed ID: 37823023
    [No Abstract]   [Full Text] [Related]  

  • 25. Stress Shielding and Bone Resorption of Press-Fit Polyether-Ether-Ketone (PEEK) Hip Prosthesis: A Sawbone Model Study.
    Naghavi SA; Lin C; Sun C; Tamaddon M; Basiouny M; Garcia-Souto P; Taylor S; Hua J; Li D; Wang L; Liu C
    Polymers (Basel); 2022 Oct; 14(21):. PubMed ID: 36365594
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A macro-micro FE and ANN framework to assess site-specific bone ingrowth around the porous beaded-coated implant: an example with BOX® tibial implant for total ankle replacement.
    Minku ; Ghosh R
    Med Biol Eng Comput; 2024 Jun; 62(6):1639-1654. PubMed ID: 38321323
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Numerical simulation of strain-adaptive bone remodelling in the ankle joint.
    Bouguecha A; Weigel N; Behrens BA; Stukenborg-Colsman C; Waizy H
    Biomed Eng Online; 2011 Jul; 10():58. PubMed ID: 21729264
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical effect of anatomical tibial component design on load distribution of medial proximal tibial bone in total knee arthroplasty : finite element analysis indicating anatomical design prevents stress-shielding.
    Cho BW; Kang KT; Kwon HM; Lee WS; Yang IH; Nam JH; Koh YG; Park KK
    Bone Joint Res; 2022 May; 11(5):252-259. PubMed ID: 35491552
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Partial revision of a dislocated periprosthetic tibial fracture after total ankle replacement with a stemmed implant and plate fixation: A case report.
    De Rito G; Biscione R; Volpe A; Liverani L; Zanoli GA; Maritati M
    Int J Surg Case Rep; 2024 Mar; 116():109336. PubMed ID: 38325111
    [TBL] [Abstract][Full Text] [Related]  

  • 30. PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study.
    Brockett CL; Carbone S; Fisher J; Jennings LM
    Wear; 2017 Mar; 374-375():86-91. PubMed ID: 28316350
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A statistical analysis of human talar shape and bone density distribution.
    Stolle J; Harper CM; Voegele KK; Najafi AR; Taheri M; MacBain J; Siegler S
    J Orthop Res; 2024 Aug; 42(8):1780-1790. PubMed ID: 38483072
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The Effect of Patient-Related Factors on the Primary Fixation of PEEK and Titanium Tibial Components: A Population-Based FE Study.
    Post CE; Bitter T; Briscoe A; van Langen I; Fluit R; Verdonschot N; Janssen D
    Bioengineering (Basel); 2024 Jan; 11(2):. PubMed ID: 38391602
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Effects of Different Femoral Component Materials on Bone and Implant Response in Total Knee Arthroplasty: A Finite Element Analysis.
    Galas A; Banci L; Innocenti B
    Materials (Basel); 2023 Aug; 16(16):. PubMed ID: 37629896
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Numerical Evaluation of a Porous Tibial-Knee Implant using Gyroid Structure.
    Eltlhawy B; Fouda N; Eldesouky I
    J Biomed Phys Eng; 2022 Feb; 12(1):75-82. PubMed ID: 35155295
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Axial rotation analysis in total ankle arthroplasty using weight-bearing computer tomography and three-dimensional modeling.
    Efrima B; Barbero A; Ovadia JE; Indino C; Maccario C; Usuelli FG
    Foot Ankle Surg; 2023 Oct; 29(7):506-510. PubMed ID: 37193615
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Metal debris release is commonly seen from explanted total ankle replacements.
    Haston S; Langton D; Townshend D; Bhalekar R; Joyce T
    J Mech Behav Biomed Mater; 2023 Aug; 144():105932. PubMed ID: 37290167
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Evaluating the validity of lightweight talar replacement designs: rational models and topologically optimized models.
    Kang Y; Kim S; Kim J; Lee JW; Park JC
    Biomater Res; 2022 Mar; 26(1):10. PubMed ID: 35287743
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Early outcomes of the Exactech Vantage fixed-bearing total ankle replacement.
    Henry JK; Shaffrey I; Wishman M; Palma Munita J; Zhu J; Cody E; Ellis S; Deland J; Demetracopoulos C
    Bone Joint J; 2023 Oct; 105-B(10):1099-1107. PubMed ID: 37777206
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Design of a lightweight universal talus implant using topology optimization.
    Hafez AH; El-Rich M; Liu T; Jomha N; Schiffer A
    Front Bioeng Biotechnol; 2023; 11():1228809. PubMed ID: 37691900
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Compliant Intramedullary Stems for Joint Reconstruction.
    Mccullough JA; Peterson BT; Upfill-Brown AM; Hardin TJ; Hopkins JB; Soohoo NF; Clites TR
    IEEE J Transl Eng Health Med; 2024; 12():314-327. PubMed ID: 38486844
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.