These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 35047877)

  • 1. Monitoring Steam Penetration in Channeled Instruments: An Evidence-Based Worst-Case for Practical Situations.
    Tessarolo F; Masè M; Visonà A; van Doornmalen Gomez Hoyos JPCM
    Front Med Technol; 2020; 2():566143. PubMed ID: 35047877
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Relation Between the Load, Duration, and Steam Penetration Capacity of a Surface Steam Sterilization Process: A Case Study.
    van Doornmalen JPCM; van Wezel RAC; Kopinga K
    PDA J Pharm Sci Technol; 2019; 73(3):276-284. PubMed ID: 30482803
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Full-cycle steam sterilization in ophthalmic surgery-the effect of wrapping instruments.
    Carpel EF; Mancera AD; Rowan LL; Entine G; Entine O
    Am J Ophthalmol; 2012 Mar; 153(3):405-411.e1. PubMed ID: 22014604
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Alternate Approach for Defining Worst Case in Steam Sterilization Validation of Porous/Hard Goods Loads.
    Chakraborty S; Soman V; Dhumal V
    PDA J Pharm Sci Technol; 2021; 75(1):91-99. PubMed ID: 32817322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Case study on the orientation of phaco hand pieces during steam sterilization processes.
    van Doornmalen Gomez Hoyos JP; van Wezel RA; van Doornmalen HW
    J Hosp Infect; 2015 May; 90(1):52-8. PubMed ID: 25726434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measuring non-condensable gases in steam.
    van Doornmalen JP; Kopinga K
    Rev Sci Instrum; 2013 Nov; 84(11):115106. PubMed ID: 24289436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Following trends in steam sterilizer performance by quantitative monitoring of non-condensable gases.
    van Wezel RAC; van Gastel A; de Ranitz A; van Doornmalen Gomez Hoyos JPCM
    J Hosp Infect; 2017 Dec; 97(4):357-362. PubMed ID: 28807833
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.
    Basu D
    J Infect Public Health; 2017; 10(2):235-239. PubMed ID: 27450707
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.
    Winter S; Smith A; Lappin D; McDonagh G; Kirk B
    J Hosp Infect; 2017 Dec; 97(4):338-342. PubMed ID: 28778810
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Parameters governing steam sterilization of deadlegs.
    Young JH; Ferko BL; Gaber RP
    J Pharm Sci Technol; 1994; 48(3):140-7. PubMed ID: 8069515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effectiveness of three types of sterilization on the contents of sharps containers.
    Sheldrake MA; Majors CD; Gaines DJ; Palenik CJ
    Quintessence Int; 1995 Nov; 26(11):771-8. PubMed ID: 8628836
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improving parametric load release for steam sterilization.
    Working Party on Improving Parametric Load Release for Steam Sterilization
    J Hosp Infect; 2023 Mar; 133():49-54. PubMed ID: 36640919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Ophthalmic Surgical Instrument Sterility Using Short-Cycle Sterilization for Sequential Same-Day Use.
    Chang DF; Hurley N; Mamalis N; Whitman J
    Ophthalmology; 2018 Sep; 125(9):1320-1324. PubMed ID: 29602568
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sterilization of various diameter dead-ended tubes.
    Young JH
    Biotechnol Bioeng; 1993 Jun; 42(1):125-32. PubMed ID: 18609656
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The Resolution of Wet Wrap Bag after Disinfected in the Pulsation Sterilizer].
    He L; Wang Q; Zheng T
    Zhongguo Yi Liao Qi Xie Za Zhi; 2016 Nov; 40(6):464-5. PubMed ID: 29792617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adaptation and validation of a portable steam sterilizer for processing intrauterine device insertion instruments and supplies in low-resource settings.
    Barone MA; Faisel AJ; Andrews L; Ahmed J; Rashida B; Kristensen D
    Am J Infect Control; 1997 Aug; 25(4):350-6. PubMed ID: 9276548
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of surgical instrument bioburden after steam sterilization: A pilot study.
    Resendiz M; Horseman TS; Hover AJ; Bradley DF; Lustik MB; West GF
    Am J Infect Control; 2020 Feb; 48(2):219-221. PubMed ID: 31604619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A survey to quantify wet loads after steam sterilization processes in healthcare facilities.
    van Doornmalen JPCM; Tessarolo F; Lapanaitis N; Henrotin K; Inglese A; Oussoren HW; Queiroz de Souza R
    J Hosp Infect; 2019 Sep; 103(1):e105-e109. PubMed ID: 31132393
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Steam sterilization--the response of the test pack.
    Wichmann R; Dennhöfer E; Dennhöfer S
    Biomed Instrum Technol; 1993; 27(5):412-8. PubMed ID: 8220636
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Tale of Two Sterilizers.
    Agalloco JP
    PDA J Pharm Sci Technol; 2020; 74(1):162-169. PubMed ID: 30770480
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.