155 related articles for article (PubMed ID: 35062423)
1. A Microfluidic Dielectric Spectroscopy System for Characterization of Biological Cells in Physiological Media.
Bakhtiari S; Manshadi MKD; Mansoorifar A; Beskok A
Sensors (Basel); 2022 Jan; 22(2):. PubMed ID: 35062423
[TBL] [Abstract][Full Text] [Related]
2. Electrical Impedance Measurements of Biological Cells in Response to External Stimuli.
Mansoorifar A; Koklu A; Ma S; Raj GV; Beskok A
Anal Chem; 2018 Apr; 90(7):4320-4327. PubMed ID: 29402081
[TBL] [Abstract][Full Text] [Related]
3. Dielectric spectroscopy as a viable biosensing tool for cell and tissue characterization and analysis.
Heileman K; Daoud J; Tabrizian M
Biosens Bioelectron; 2013 Nov; 49():348-59. PubMed ID: 23796534
[TBL] [Abstract][Full Text] [Related]
4. Dielectrophoresis assisted loading and unloading of microwells for impedance spectroscopy.
Mansoorifar A; Koklu A; Sabuncu AC; Beskok A
Electrophoresis; 2017 Jun; 38(11):1466-1474. PubMed ID: 28256738
[TBL] [Abstract][Full Text] [Related]
5. Microtrap electrode devices for single cell trapping and impedance measurement.
Mondal D; Roychaudhuri C; Das L; Chatterjee J
Biomed Microdevices; 2012 Oct; 14(5):955-64. PubMed ID: 22767244
[TBL] [Abstract][Full Text] [Related]
6. Dielectric properties of isolated adrenal chromaffin cells determined by microfluidic impedance spectroscopy.
Sabuncu AC; Stacey M; Craviso GL; Semenova N; Vernier PT; Leblanc N; Chatterjee I; Zaklit J
Bioelectrochemistry; 2018 Feb; 119():84-91. PubMed ID: 28918192
[TBL] [Abstract][Full Text] [Related]
7. Microfluidic channel sensory system for electro-addressing cell location, determining confluency, and quantifying a general number of cells.
Rapier CE; Jagadeesan S; Vatine G; Ben-Yoav H
Sci Rep; 2022 Feb; 12(1):3248. PubMed ID: 35228609
[TBL] [Abstract][Full Text] [Related]
8. Concepts, electrode configuration, characterization, and data analytics of electric and electrochemical microfluidic platforms: a review.
Nguyen TH; Nguyen HA; Tran Thi YV; Hoang Tran D; Cao H; Chu Duc T; Bui TT; Do Quang L
Analyst; 2023 May; 148(9):1912-1929. PubMed ID: 36928639
[TBL] [Abstract][Full Text] [Related]
9. New Microfluidic System for Electrochemical Impedance Spectroscopy Assessment of Cell Culture Performance: Design and Development of New Electrode Material.
Chmayssem A; Tanase CE; Verplanck N; Gougis M; Mourier V; Zebda A; Ghaemmaghami AM; Mailley P
Biosensors (Basel); 2022 Jun; 12(7):. PubMed ID: 35884254
[TBL] [Abstract][Full Text] [Related]
10. Dynamic monitoring of single cell lysis in an impedance-based microfluidic device.
Zhou Y; Basu S; Laue ED; Seshia AA
Biomed Microdevices; 2016 Aug; 18(4):56. PubMed ID: 27299468
[TBL] [Abstract][Full Text] [Related]
11. Electrode-Electrolyte Interface Impedance Characterization of Ultra-Miniaturized Microelectrode Arrays Over Materials and Geometries for Sub-Cellular and Cellular Sensing and Stimulation.
Wang A; Jung D; Park J; Junek G; Wang H
IEEE Trans Nanobioscience; 2019 Apr; 18(2):248-252. PubMed ID: 30892229
[TBL] [Abstract][Full Text] [Related]
12. Real-time monitoring of epithelial barrier function by impedance spectroscopy in a microfluidic platform.
Fernandes J; Karra N; Bowring J; Reale R; James J; Blume C; Pell TJ; Rowan WC; Davies DE; Swindle EJ; Morgan H
Lab Chip; 2022 May; 22(10):2041-2054. PubMed ID: 35485428
[TBL] [Abstract][Full Text] [Related]
13. Interdigitated microelectrode-based microchip for electrical impedance spectroscopic study of oral cancer cells.
Mamouni J; Yang L
Biomed Microdevices; 2011 Dec; 13(6):1075-88. PubMed ID: 21833766
[TBL] [Abstract][Full Text] [Related]
14. Optimization, fabrication, and characterization of four electrode-based sensors for blood impedance measurement.
Pradhan R; Raisa SA; Kumar P; Kalkal A; Kumar N; Packirisamy G; Manhas S
Biomed Microdevices; 2021 Jan; 23(1):9. PubMed ID: 33449205
[TBL] [Abstract][Full Text] [Related]
15. Microfluidic device for cell capture and impedance measurement.
Jang LS; Wang MH
Biomed Microdevices; 2007 Oct; 9(5):737-43. PubMed ID: 17508285
[TBL] [Abstract][Full Text] [Related]
16. Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations.
Gawad S; Cheung K; Seger U; Bertsch A; Renaud P
Lab Chip; 2004 Jun; 4(3):241-51. PubMed ID: 15159786
[TBL] [Abstract][Full Text] [Related]
17. How to Choose a Proper Theoretical Analysis Model Based on Cell Adhesion and Nonadhesion Impedance Measurement.
Wei M; Zhang R; Zhang F; Yang N; Zhang Y; Li G
ACS Sens; 2021 Mar; 6(3):673-687. PubMed ID: 33724797
[TBL] [Abstract][Full Text] [Related]
18. Dielectric spectroscopy of red blood cells in sickle cell disease.
Liu J; Qiang Y; Du E
Electrophoresis; 2021 Mar; 42(5):667-675. PubMed ID: 33314275
[TBL] [Abstract][Full Text] [Related]
19. Interpreting Dynamic Interfacial Changes at Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.
Meunier CJ; Denison JD; McCarty GS; Sombers LA
Langmuir; 2020 Apr; 36(15):4214-4223. PubMed ID: 32216254
[TBL] [Abstract][Full Text] [Related]
20. Dielectric spectroscopy of single human erythrocytes at physiological ionic strength: dispersion of the cytoplasm.
Gimsa J; Müller T; Schnelle T; Fuhr G
Biophys J; 1996 Jul; 71(1):495-506. PubMed ID: 8804632
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]