These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 35083117)
1. Diagnostic Accuracy of Dobutamine Stress Echocardiography for Detection of Cardiac Allograft Vasculopathy in Orthotopic Heart Transplant Patients. Mahmoodurrahman M; Marek J; Juhardeen HR; Al Otaibi T; Salemi VMC; Echahidi N; Al Buraiki J; Fadel BM; Mohty D J Saudi Heart Assoc; 2021; 33(4):279-283. PubMed ID: 35083117 [TBL] [Abstract][Full Text] [Related]
2. Assessment of the progression of cardiac allograft vasculopathy by dobutamine stress echocardiography. Derumeaux G; Redonnet M; Soyer R; Cribier A; Letac B J Heart Lung Transplant; 1998 Mar; 17(3):259-67. PubMed ID: 9563602 [TBL] [Abstract][Full Text] [Related]
3. European Association of Cardiovascular Imaging/Cardiovascular Imaging Department of the Brazilian Society of Cardiology recommendations for the use of cardiac imaging to assess and follow patients after heart transplantation. Badano LP; Miglioranza MH; Edvardsen T; Colafranceschi AS; Muraru D; Bacal F; Nieman K; Zoppellaro G; Marcondes Braga FG; Binder T; Habib G; Lancellotti P; Eur Heart J Cardiovasc Imaging; 2015 Sep; 16(9):919-48. PubMed ID: 26139361 [TBL] [Abstract][Full Text] [Related]
4. Follow-up of heart transplant recipients with serial echocardiographic coronary flow reserve and dobutamine stress echocardiography to detect cardiac allograft vasculopathy. Sade LE; Eroğlu S; Yüce D; Bircan A; Pirat B; Sezgin A; Aydınalp A; Müderrisoğlu H J Am Soc Echocardiogr; 2014 May; 27(5):531-9. PubMed ID: 24613313 [TBL] [Abstract][Full Text] [Related]
5. [Quantitative dobutamine stress echocardiography in follow-up of heart transplantation: normal values and findings in patients with transplant vasculopathy]. Spes CH; Klauss V; Mudra H; Schnaack SD; Tammen AR; Weisenseel P; Rieber J; Henneke KH; Uberfuhr P; Reichart B; Theisen K; Angermann CE Z Kardiol; 1997 Oct; 86(10):868-76. PubMed ID: 9454455 [TBL] [Abstract][Full Text] [Related]
6. Diagnostic accuracy of dobutamine stress echocardiography in the detection of cardiac allograft vasculopathy in heart transplant recipients: A systematic review and meta-analysis study. Elkaryoni A; Abu-Sheasha G; Altibi AM; Hassan A; Ellakany K; Nanda NC Echocardiography; 2019 Mar; 36(3):528-536. PubMed ID: 30726558 [TBL] [Abstract][Full Text] [Related]
7. Dobutamine stress echocardiography for noninvasive diagnosis of cardiac allograft vasculopathy: a comparison with angiography and intravascular ultrasound. Spes CH; Mudra H; Schnaack SD; Klauss V; Reichle FM; Uberfuhr P; Theisen K; Angermann CE Am J Cardiol; 1996 Jul; 78(2):168-74. PubMed ID: 8712138 [TBL] [Abstract][Full Text] [Related]
8. Dobutamine stress echocardiography during follow-up surveillance in heart transplant patients: Diagnostic accuracy and predictors of outcomes. Chirakarnjanakorn S; Starling RC; Popović ZB; Griffin BP; Desai MY J Heart Lung Transplant; 2015 May; 34(5):710-7. PubMed ID: 25682552 [TBL] [Abstract][Full Text] [Related]
9. Feasibility of Real-Time Myocardial Contrast Echocardiography to Detect Cardiac Allograft Vasculopathy in Pediatric Heart Transplant Recipients. Fine NM; Greenway SC; Mulvagh SL; Huang R; Maxon SA; Hepinstall MJ; Anderson JH; Johnson JN J Am Soc Echocardiogr; 2021 May; 34(5):503-510. PubMed ID: 33359634 [TBL] [Abstract][Full Text] [Related]
10. [Initial experiences with dobutamine stress echocardiography in heart transplant patients]. Günther F; Schwammenthal E; Rahmel A; Lamp B; Kerber S; Deng M; Scheld HH; Breithardt G Z Kardiol; 1995 May; 84(5):411-8. PubMed ID: 7625105 [TBL] [Abstract][Full Text] [Related]
11. Stress echocardiography: abnormal tissue Doppler imaging in the absence of cardiac allograft vasculopathy in heart transplant recipients. Nguyen T; Ahmadie R; Fang T; Lytwyn M; Francis A; Barac I; Hussain F; Zieroth S; Jassal DS Echocardiography; 2009 Feb; 26(2):182-8. PubMed ID: 19054033 [TBL] [Abstract][Full Text] [Related]
13. Functional and morphological findings in heart transplant recipients with a normal coronary angiogram: an analysis by dobutamine stress echocardiography, intracoronary Doppler and intravascular ultrasound. Spes CH; Klauss V; Rieber J; Schnaack SD; Tammen AR; Uberfuhr P; Reichart B; Theisen K; Angermann CE; Mudra H J Heart Lung Transplant; 1999 May; 18(5):391-8. PubMed ID: 10363681 [TBL] [Abstract][Full Text] [Related]
14. Stress echocardiography for assessment of cardiac allograft vasculopathy. Spes CH; Angermann CE Z Kardiol; 2000; 89 Suppl 9():IX/50-3. PubMed ID: 11151793 [TBL] [Abstract][Full Text] [Related]
15. Magnetic Resonance for Noninvasive Detection of Microcirculatory Disease Associated With Allograft Vasculopathy: Intracoronary Measurement Validation. Mirelis JG; García-Pavía P; Cavero MA; González-López E; Echavarria-Pinto M; Pastrana M; Segovia J; Oteo JF; Alonso-Pulpón L; Escaned J Rev Esp Cardiol (Engl Ed); 2015 Jul; 68(7):571-8. PubMed ID: 25522835 [TBL] [Abstract][Full Text] [Related]
16. Stress echocardiography for the diagnosis of coronary artery disease: an evidence-based analysis. Medical Advisory Secretariat Ont Health Technol Assess Ser; 2010; 10(9):1-61. PubMed ID: 23074412 [TBL] [Abstract][Full Text] [Related]
17. Resting echocardiography and quantitative dipyridamole technetium-99m sestamibi tomography in the identification of cardiac allograft vasculopathy and the prediction of long-term prognosis after heart transplantation. Ciliberto GR; Ruffini L; Mangiavacchi M; Parolini M; Sara R; Massa D; De Maria R; Gronda E; Vitali E; Parodi O Eur Heart J; 2001 Jun; 22(11):964-71. PubMed ID: 11428820 [TBL] [Abstract][Full Text] [Related]
18. Dobutamine stress echocardiography early after heart transplantation predicts development of allograft coronary artery disease and outcome. Akosah KO; McDaniel S; Hanrahan JS; Mohanty PK J Am Coll Cardiol; 1998 Jun; 31(7):1607-14. PubMed ID: 9626841 [TBL] [Abstract][Full Text] [Related]