These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

38 related articles for article (PubMed ID: 3508786)

  • 21. Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.
    Vock L; Menapace R; Stifter E; Georgopoulos M; Sacu S; Bühl W
    J Cataract Refract Surg; 2009 Mar; 35(3):459-65. PubMed ID: 19251138
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hydrophobic acrylic and plate-haptic silicone intraocular lens implantation in diabetic patients: pilot randomized clinical trial.
    Elgohary MA; Hollick EJ; Bender LE; Heatley CJ; Wren SM; Boyce J; Missotten T; Spalton DJ; Dowler JG
    J Cataract Refract Surg; 2006 Jul; 32(7):1188-95. PubMed ID: 16857508
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Greenish discoloration of an AMO SI-30NB silicone intraocular lens.
    Ashraf KM; Siddique M; Zia R; Qazi Zu
    Acta Ophthalmol Scand; 2005 Aug; 83(4):518-9. PubMed ID: 16029288
    [No Abstract]   [Full Text] [Related]  

  • 24. Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery.
    Vock L; Crnej A; Findl O; Neumayer T; Buehl W; Sacu S; Rainer G; Menapace R
    Am J Ophthalmol; 2009 Apr; 147(4):683-690.e2. PubMed ID: 19201391
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.
    Izak AM; Werner L; Apple DJ; Pandey SK; Trivedi RH
    Ophthalmic Surg Lasers; 2002; 33(6):480-7. PubMed ID: 12449223
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Consultation section. Anterior capsulotomy to treat nasal decentration of the intraocular lens.
    J Cataract Refract Surg; 2001 Feb; 27(2):181-7. PubMed ID: 11226772
    [No Abstract]   [Full Text] [Related]  

  • 27. Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: five-year results of a randomized study.
    Sacu S; Menapace R; Findl O; Kiss B; Buehl W; Georgopoulos M
    Am J Ophthalmol; 2005 Apr; 139(4):696-703. PubMed ID: 15808167
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Ten-year follow-up of a ciliary sulcus-fixated silicone phakic posterior chamber intraocular lens.
    Kohnen T; Kasper T; Bühren J; Fechner PU
    J Cataract Refract Surg; 2004 Nov; 30(11):2431-4. PubMed ID: 15519102
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Neodymium:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses.
    Ram J; Kaushik S; Brar GS; Gupta A
    Ophthalmic Surg Lasers; 2001; 32(5):375-82. PubMed ID: 11563781
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Surface calcification of a 3-piece silicone intraocular lens in a patient with asteroid hyalosis: a clinicopathologic case report.
    Werner L; Kollarits CR; Mamalis N; Olson RJ
    Ophthalmology; 2005 Mar; 112(3):447-52. PubMed ID: 15745772
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification.
    Buehl W; Menapace R; Findl O; Neumayer T; Bolz M; Prinz A
    Am J Ophthalmol; 2007 Jun; 143(6):913-919. PubMed ID: 17399674
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Soft intraocular lenses.
    Allarakhia L; Lindstrom RL
    Int Ophthalmol; 1988; 12(3):185-91. PubMed ID: 3068172
    [No Abstract]   [Full Text] [Related]  

  • 33. Passport system cutting of a chiron C10 UB silicone lens.
    Olson RJ
    J Cataract Refract Surg; 1996 Apr; 22(3):282. PubMed ID: 8778356
    [No Abstract]   [Full Text] [Related]  

  • 34. Preparation techniques for silicone gel in the evaluation of its in vivo effects.
    Semple JL; Narini PP; Hay JB
    Plast Reconstr Surg; 1993 Oct; 92(5):979-81. PubMed ID: 8415988
    [No Abstract]   [Full Text] [Related]  

  • 35. In Regard to Verma et al.
    Alamri Y
    Int J Radiat Oncol Biol Phys; 2016 Nov; 96(4):924. PubMed ID: 27788969
    [No Abstract]   [Full Text] [Related]  

  • 36. The fromberg-Verma (FV) silicone lens--a series of 75 cases.
    Alexander TA; Thomas R; Thomas V
    Indian J Ophthalmol; 1987; 35(5-6):257-9. PubMed ID: 3508786
    [No Abstract]   [Full Text] [Related]  

  • 37.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 38.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]     [New Search]
    of 2.