156 related articles for article (PubMed ID: 35094497)
1. Computational study of a novel catheter for liver radioembolization.
Ortega J; Antón R; Ramos JC; Rivas A; S Larraona G; Sangro B; Bilbao JI; Aramburu J
Int J Numer Method Biomed Eng; 2022 Apr; 38(4):e3577. PubMed ID: 35094497
[TBL] [Abstract][Full Text] [Related]
2. Numerical investigation of liver radioembolization via computational particle-hemodynamics: The role of the microcatheter distal direction and microsphere injection point and velocity.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
J Biomech; 2016 Nov; 49(15):3714-3721. PubMed ID: 27751569
[TBL] [Abstract][Full Text] [Related]
3. The role of angled-tip microcatheter and microsphere injection velocity in liver radioembolization: A computational particle-hemodynamics study.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
Int J Numer Method Biomed Eng; 2017 Dec; 33(12):. PubMed ID: 28474382
[TBL] [Abstract][Full Text] [Related]
4. Computational assessment of the effects of the catheter type on particle-hemodynamics during liver radioembolization.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
J Biomech; 2016 Nov; 49(15):3705-3713. PubMed ID: 27751570
[TBL] [Abstract][Full Text] [Related]
5. On the importance of spiral-flow inflow boundary conditions when using idealized artery geometries in the analysis of liver radioembolization: A parametric study.
Ortega J; Antón R; Ramos JC; Rivas A; Larraona GS; Sangro B; Bilbao JI; Aramburu J
Int J Numer Method Biomed Eng; 2020 Jun; 36(6):e3337. PubMed ID: 32212316
[TBL] [Abstract][Full Text] [Related]
6. Computational particle-haemodynamics analysis of liver radioembolization pretreatment as an actual treatment surrogate.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
Int J Numer Method Biomed Eng; 2017 Feb; 33(2):. PubMed ID: 27038438
[TBL] [Abstract][Full Text] [Related]
7. Computer modeling of controlled microsphere release and targeting in a representative hepatic artery system.
Basciano CA; Kleinstreuer C; Kennedy AS; Dezarn WA; Childress E
Ann Biomed Eng; 2010 May; 38(5):1862-79. PubMed ID: 20162358
[TBL] [Abstract][Full Text] [Related]
8. Liver Radioembolization: An Analysis of Parameters that Influence the Catheter-Based Particle-Delivery via CFD.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
Curr Med Chem; 2020; 27(10):1600-1615. PubMed ID: 29932032
[TBL] [Abstract][Full Text] [Related]
9. A new catheter for tumor targeting with radioactive microspheres in representative hepatic artery systems. Part I: impact of catheter presence on local blood flow and microsphere delivery.
Kleinstreuer C; Basciano CA; Childress EM; Kennedy AS
J Biomech Eng; 2012 May; 134(5):051004. PubMed ID: 22757492
[TBL] [Abstract][Full Text] [Related]
10. Computer modeling of yttrium-90-microsphere transport in the hepatic arterial tree to improve clinical outcomes.
Kennedy AS; Kleinstreuer C; Basciano CA; Dezarn WA
Int J Radiat Oncol Biol Phys; 2010 Feb; 76(2):631-7. PubMed ID: 19910131
[TBL] [Abstract][Full Text] [Related]
11. Innovation in catheter design for intra-arterial liver cancer treatments results in favorable particle-fluid dynamics.
van den Hoven AF; Lam MG; Jernigan S; van den Bosch MA; Buckner GD
J Exp Clin Cancer Res; 2015 Aug; 34(1):74. PubMed ID: 26231929
[TBL] [Abstract][Full Text] [Related]
12. Solid Tumor Embolotherapy in Hepatic Arteries with an Anti-reflux Catheter System.
Xu Z; Jernigan S; Kleinstreuer C; Buckner GD
Ann Biomed Eng; 2016 Apr; 44(4):1036-46. PubMed ID: 26265458
[TBL] [Abstract][Full Text] [Related]
13. A Hybrid Particle-Flow CFD Modeling Approach in Truncated Hepatic Arterial Trees for Liver Radioembolization: A Patient-specific Case Study.
Bomberna T; Vermijs S; Lejoly M; Verslype C; Bonne L; Maleux G; Debbaut C
Front Bioeng Biotechnol; 2022; 10():914979. PubMed ID: 35711632
[TBL] [Abstract][Full Text] [Related]
14. A new catheter for tumor-targeting with radioactive microspheres in representative hepatic artery systems--part II: solid tumor-targeting in a patient-inspired hepatic artery system.
Childress EM; Kleinstreuer C; Kennedy AS
J Biomech Eng; 2012 May; 134(5):051005. PubMed ID: 22757493
[TBL] [Abstract][Full Text] [Related]
15. Computational Modeling of the Liver Arterial Blood Flow for Microsphere Therapy: Effect of Boundary Conditions.
Taebi A; Pillai RM; Roudsari BS; Vu CT; Roncali E
Bioengineering (Basel); 2020 Jun; 7(3):. PubMed ID: 32610459
[TBL] [Abstract][Full Text] [Related]
16. Computational Fluid Dynamics Modeling of Liver Radioembolization: A Review.
Aramburu J; Antón R; Rodríguez-Fraile M; Sangro B; Bilbao JI
Cardiovasc Intervent Radiol; 2022 Jan; 45(1):12-20. PubMed ID: 34518913
[TBL] [Abstract][Full Text] [Related]
17. Liver cancer arterial perfusion modelling and CFD boundary conditions methodology: a case study of the haemodynamics of a patient-specific hepatic artery in literature-based healthy and tumour-bearing liver scenarios.
Aramburu J; Antón R; Rivas A; Ramos JC; Sangro B; Bilbao JI
Int J Numer Method Biomed Eng; 2016 Nov; 32(11):. PubMed ID: 26727946
[TBL] [Abstract][Full Text] [Related]
18. Transarterial radioembolization: a systematic review on gaining control over the parameters that influence microsphere distribution.
Snoeijink TJ; Vlogman TG; Roosen J; Groot Jebbink E; Jain K; Nijsen JFW
Drug Deliv; 2023 Dec; 30(1):2226366. PubMed ID: 37341184
[No Abstract] [Full Text] [Related]
19. Radioembolization of Colorectal Liver Metastases: Indications, Technique, and Outcomes.
Boas FE; Bodei L; Sofocleous CT
J Nucl Med; 2017 Sep; 58(Suppl 2):104S-111S. PubMed ID: 28864605
[TBL] [Abstract][Full Text] [Related]
20. Personalized Dosimetry for Liver Cancer Y-90 Radioembolization Using Computational Fluid Dynamics and Monte Carlo Simulation.
Roncali E; Taebi A; Foster C; Vu CT
Ann Biomed Eng; 2020 May; 48(5):1499-1510. PubMed ID: 32006268
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]