These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 35095014)

  • 1. Improving image quality by optimizing beam width and helical pitch in CT.
    Jeon PH; Lee CL
    J Xray Sci Technol; 2022; 30(2):399-408. PubMed ID: 35095014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.
    Brisse HJ; Madec L; Gaboriaud G; Lemoine T; Savignoni A; Neuenschwander S; Aubert B; Rosenwald JC
    Med Phys; 2007 Jul; 34(7):3018-33. PubMed ID: 17822010
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms.
    Zhang D; Savandi AS; Demarco JJ; Cagnon CH; Angel E; Turner AC; Cody DD; Stevens DM; Primak AN; McCollough CH; McNitt-Gray MF
    Med Phys; 2009 Mar; 36(3):1025-38. PubMed ID: 19378763
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.
    Flohr TG; Leng S; Yu L; Aiimendinger T; Bruder H; Petersilka M; Eusemann CD; Stierstorfer K; Schmidt B; McCollough CH
    Med Phys; 2009 Dec; 36(12):5641-53. PubMed ID: 20095277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.
    Tzedakis A; Damilakis J; Perisinakis K; Stratakis J; Gourtsoyiannis N
    Med Phys; 2005 Jun; 32(6):1621-9. PubMed ID: 16013721
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: Initial experience with 3
    Hagelstein C; Henzler T; Haubenreisser H; Meyer M; Sudarski S; Schoenberg SO; Neff KW; Weis M
    Z Med Phys; 2016 Dec; 26(4):349-361. PubMed ID: 26702762
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Influence of maximum tube current threshold in automatic exposure control at 64-detector row CT: relationship between radiation dose reduction rate and variability of image noise].
    Shirasaka T; Funama Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2009 Mar; 65(3):295-300. PubMed ID: 19367062
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom.
    Ohno Y; Koyama H; Kono A; Terada M; Inokawa H; Matsumoto S; Sugimura K
    Eur J Radiol; 2007 Dec; 64(3):406-13. PubMed ID: 17884323
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Evaluation and comparison of dose profiles and patient doses among X-ray CT scanners].
    Matsubara K; Koshida K; Suzuki M; Fukuda A; Kawabata C; Tsujii H; Mizushima T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 May; 61(5):683-90. PubMed ID: 15915142
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.
    Men K; Dai J
    Technol Cancer Res Treat; 2017 Dec; 16(6):1179-1186. PubMed ID: 29332447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.
    Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
    Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.
    So A; Imai Y; Nett B; Jackson J; Nett L; Hsieh J; Wisenberg G; Teefy P; Yadegari A; Islam A; Lee TY
    Med Phys; 2016 Aug; 43(8):4821. PubMed ID: 27487900
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Image quality and dose optimisation for infant CT using a paediatric phantom.
    Lambert JW; Phelps AS; Courtier JL; Gould RG; MacKenzie JD
    Eur Radiol; 2016 May; 26(5):1387-95. PubMed ID: 26304803
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
    Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
    Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study.
    van Ommen F; Bennink E; Vlassenbroek A; Dankbaar JW; Schilham AMR; Viergever MA; de Jong HWAM
    Med Phys; 2018 Jul; 45(7):3031-3042. PubMed ID: 29749624
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.
    Flohr TG; Stierstorfer K; Ulzheimer S; Bruder H; Primak AN; McCollough CH
    Med Phys; 2005 Aug; 32(8):2536-47. PubMed ID: 16193784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image reconstruction and image quality evaluation for a dual source CT scanner.
    Flohr TG; Bruder H; Stierstorfer K; Petersilka M; Schmidt B; McCollough CH
    Med Phys; 2008 Dec; 35(12):5882-97. PubMed ID: 19175144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.
    Fahimian BP; Zhao Y; Huang Z; Fung R; Mao Y; Zhu C; Khatonabadi M; DeMarco JJ; Osher SJ; McNitt-Gray MF; Miao J
    Med Phys; 2013 Mar; 40(3):031914. PubMed ID: 23464329
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-pitch, 120 kVp/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers.
    Lim HK; Ha HI; Hwang HJ; Lee K
    PLoS One; 2019; 14(1):e0211097. PubMed ID: 30677082
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]