BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 35097356)

  • 1. Biomechanical Comparison of First Tarsometatarsal Arthrodesis Constructs Over Prolonged Cyclic Testing.
    Prieto-Diaz C; Anderle MR; Brinker LZ; Allard R; Leasure J
    Foot Ankle Orthop; 2019 Oct; 4(4):2473011419892240. PubMed ID: 35097356
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stability of medial locking plate and compression screw versus two crossed screws for lapidus arthrodesis.
    Klos K; Gueorguiev B; Mückley T; Fröber R; Hofmann GO; Schwieger K; Windolf M
    Foot Ankle Int; 2010 Feb; 31(2):158-63. PubMed ID: 20132754
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanics of common fixation devices for first tarsometatarsal joint fusion-a comparative study with synthetic bones.
    Burchard R; Massa R; Soost C; Richter W; Dietrich G; Ohrndorf A; Christ HJ; Fritzen CP; Graw JA; Schmitt J
    J Orthop Surg Res; 2018 Jul; 13(1):176. PubMed ID: 29996853
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Evaluation of Tarsometatarsal Fusion Comparing Crossing Lag Screws and Lag Screw With Locking Plate.
    Ettinger S; Hemmersbach LC; Schwarze M; Stukenborg-Colsman C; Yao D; Plaass C; Claassen L
    Foot Ankle Int; 2022 Jan; 43(1):77-85. PubMed ID: 34351215
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
    Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
    Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
    [TBL] [Abstract][Full Text] [Related]  

  • 6. First Tarsometatarsal Joint Fusion for Hallux Valgus Deformity: A Retrospective Comparison of Two Fixation Constructs Regarding Initial Maintenance of Correction and Complications: Traditional Crossing Screw Fixation Versus Dorsomedial Locking Plate and Intercuneiform Compression Screw.
    Abben KW; Sakow CF; Sorensen T; Chang HC; Boffeli TJ
    J Foot Ankle Surg; 2023; 62(2):347-354. PubMed ID: 36272952
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical Comparison of Low-Profile Contoured Locking Plate With Single Compression Screw to Fully Threaded Compression Screws for First MTP Fusion.
    Fuld RS; Kumparatana P; Kelley J; Anderson N; Baldini T; Younger ASE; Hunt KJ
    Foot Ankle Int; 2019 Jul; 40(7):836-844. PubMed ID: 30880450
    [TBL] [Abstract][Full Text] [Related]  

  • 8. First Tarsometatarsal Joint Fusion in Foot-A Biomechanical Human Anatomical Specimen Analysis with Use of Low-Profile Nitinol Staples Acting as Continuous Compression Implants.
    Sands A; Zderic I; Swords M; Gehweiler D; Ciric D; Roth C; Nötzli C; Gueorguiev B
    Medicina (Kaunas); 2023 Jul; 59(7):. PubMed ID: 37512121
    [No Abstract]   [Full Text] [Related]  

  • 9. Stability of Locking Plate and Compression Screws for Lapidus Arthrodesis: A Biomechanical Comparison of Plate Position.
    Drummond D; Motley T; Kosmopoulos V; Ernst J
    J Foot Ankle Surg; 2018; 57(3):466-470. PubMed ID: 29472168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.
    Aiyer A; Russell NA; Pelletier MH; Myerson M; Walsh WR
    Foot Ankle Spec; 2016 Jun; 9(3):232-40. PubMed ID: 26655080
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Crossed-screws provide greater tarsometatarsal fusion stability compared to compression plates.
    Baxter JR; Mani SB; Chan JY; Vulcano E; Ellis SJ
    Foot Ankle Spec; 2015 Apr; 8(2):95-100. PubMed ID: 25053793
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Lapidus Arthrodesis: Examining the Effect of the Metatarsal Base Transfixion Screw.
    Ehredt DJ; Kawalec J; Ligas C; Seidel J; Benson B; Reiner MM; Connors J
    J Foot Ankle Surg; 2021; 60(2):333-338. PubMed ID: 33349538
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical comparison of a locking plate with intraplate compression screw versus locking plate with plantar interfragmentary screw for Lapidus arthrodesis: a cadaveric study.
    Cottom JM; Rigby RB
    J Foot Ankle Surg; 2013; 52(3):339-42. PubMed ID: 23621977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.
    Huh J; Glisson RR; Matsumoto T; Easley ME
    Foot Ankle Int; 2016 Apr; 37(4):411-8. PubMed ID: 26637274
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraosseous fixation compared to plantar plate fixation for first metatarsocuneiform arthrodesis: a cadaveric biomechanical analysis.
    Roth KE; Peters J; Schmidtmann I; Maus U; Stephan D; Augat P
    Foot Ankle Int; 2014 Nov; 35(11):1209-16. PubMed ID: 25121509
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of Locking Plate with Interfragmentary Screw Versus Plantarly Applied Anatomic Locking Plate for Lapidus Arthrodesis: A Biomechanical Cadaveric Study.
    Cottom JM; Baker JS
    Foot Ankle Spec; 2017 Jun; 10(3):227-231. PubMed ID: 27837037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Maintenance of Correction of the Modified Lapidus Procedure With a First Metatarsal to Intermediate Cuneiform Cross-Screw Technique.
    Langan TM; Greschner JM; Brandão RA; Goss DA; Smith CN; Hyer CF
    Foot Ankle Int; 2020 Apr; 41(4):428-436. PubMed ID: 31878798
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures.
    Hsiao CK; Tsai YJ; Yen CY; Lee CH; Yang TY; Tu YK
    BMC Musculoskelet Disord; 2017 Feb; 18(1):64. PubMed ID: 28153021
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.
    Kim JS; Cho HK; Young KW; Kim JS; Lee KT
    Clin Orthop Surg; 2017 Dec; 9(4):514-520. PubMed ID: 29201305
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Crossed screws versus dorsomedial locking plate with compression screw for first metatarsocuneiform arthrodesis: a cadaver study.
    Gruber F; Sinkov VS; Bae SY; Parks BG; Schon LC
    Foot Ankle Int; 2008 Sep; 29(9):927-30. PubMed ID: 18778673
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.