BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 35098810)

  • 1. Modeling attachment and compressive loading of locking and non-locking plate fixation: a finite element investigation of a supracondylar femur fracture model.
    Samiezadeh A; McLachlin S; Ng M; Samiezadeh S; Larouche J; Whyne C
    Comput Methods Biomech Biomed Engin; 2022 Nov; 25(14):1629-1636. PubMed ID: 35098810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
    Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
    Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Proximal Screw Configuration Alters Peak Plate Strain Without Changing Construct Stiffness in Comminuted Supracondylar Femur Fractures.
    McLachlin S; Kreder H; Ng M; Jenkinson R; Whyne C; Larouche J
    J Orthop Trauma; 2017 Dec; 31(12):e418-e424. PubMed ID: 28902085
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A new exploration and consideration of Type A fracture of distal femur based on finite element biomechanical analysis].
    Xu D; Sun RJ; Wang TY; Zhao XQ; Bi ZG; Geng S
    Zhonghua Wai Ke Za Zhi; 2019 Nov; 57(11):812-817. PubMed ID: 31694128
    [No Abstract]   [Full Text] [Related]  

  • 5. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.
    Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G
    J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis].
    An Y; Jiang D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Jun; 37(6):688-693. PubMed ID: 37331944
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element analysis of double-plate fixation using reversed locking compression-distal femoral plates for Vancouver B1 periprosthetic femoral fractures.
    Takahashi D; Noyama Y; Asano T; Shimizu T; Irie T; Terkawi MA; Iwasaki N
    BMC Musculoskelet Disord; 2021 Mar; 22(1):276. PubMed ID: 33714273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures.
    Weaver MJ; Chaus GW; Masoudi A; Momenzadeh K; Mohamadi A; Rodriguez EK; Vrahas MS; Nazarian A
    BMC Musculoskelet Disord; 2021 Jun; 22(1):512. PubMed ID: 34088275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading.
    Märdian S; Schaser KD; Duda GN; Heyland M
    Clin Biomech (Bristol, Avon); 2015 May; 30(4):391-6. PubMed ID: 25716162
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
    Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
    Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis.
    Zhang J; Wei Y; Li G; Wang J; Xu Y
    Acta Orthop Traumatol Turc; 2021 Jan; 55(1):9-15. PubMed ID: 33650504
    [TBL] [Abstract][Full Text] [Related]  

  • 12. What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis.
    Rao J; Zhang J; Ye Z; Zhang L; Xu J
    J Orthop Surg Res; 2023 Oct; 18(1):759. PubMed ID: 37805559
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Finite Element Analysis of Screw Layout of Locking Plate for Treating Femoral Shaft Fracture].
    Sheng W; Ji A; Chen C
    Zhongguo Yi Liao Qi Xie Za Zhi; 2017 May; 41(3):196-199. PubMed ID: 29862767
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis.
    Yang P; Zhang Y; Liu J; Xiao J; Ma LM; Zhu CR
    Acta Orthop Traumatol Turc; 2015; 49(2):203-9. PubMed ID: 26012943
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System.
    Sheng W; Ji A; Fang R; He G; Chen C
    Comput Math Methods Med; 2019; 2019():5636528. PubMed ID: 31531124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of a multidimensional cross locking plate versus a locking compression plate for the treatment of femoral shaft nonunion: Finite element analysis.
    Zhang W; Hao M; Chang Z; Wu Y; Tang P; Chen H
    Med Eng Phys; 2020 Sep; 83():106-111. PubMed ID: 32507679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical optimization of the far cortical locking technique for early healing of distal femur fractures.
    Sarwar A; Gee A; Bougherara H; Kuzyk PRT; Schemitsch EH; Zdero R
    Med Eng Phys; 2021 Mar; 89():63-72. PubMed ID: 33608126
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
    Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
    J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of optimal screw configurations in two locking plate systems for proximal humerus fixation - a finite element analysis study.
    Mischler D; Babu S; Osterhoff G; Pari C; Fletcher J; Windolf M; Gueorguiev B; Varga P
    Clin Biomech (Bristol, Avon); 2020 Aug; 78():105097. PubMed ID: 32623297
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of bone cement augmentation with different configurations of the dual locking plate for femoral allograft fixation: finite element analysis and biomechanical study.
    Wisanuyotin T; Paholpak P; Sirichativapee W; Sirichativapee W; Kosuwon W
    J Orthop Surg Res; 2023 Jun; 18(1):405. PubMed ID: 37270556
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.