BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 35100337)

  • 1. Use of Anthropometric Indices to Identify Appropriate Cuff Shapes for Blood Pressure Measurement: Normative Data for Adults.
    Palatini P; Fania C; Ermolao A; Battista F; Saladini F
    Am J Hypertens; 2022 Jun; 35(6):526-532. PubMed ID: 35100337
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of the shape of the cuff on blood pressure measurement in people with large arms.
    Palatini P; Benetti E; Fania C; Ermolao A; Spinella P; Battista F; Gasperetti A; Saladini F
    Blood Press; 2020 Aug; 29(4):241-246. PubMed ID: 32172593
    [No Abstract]   [Full Text] [Related]  

  • 3. Only troncoconical cuffs can provide accurate blood pressure measurements in people with severe obesity.
    Palatini P; Benetti E; Fania C; Saladini F
    J Hypertens; 2019 Jan; 37(1):37-41. PubMed ID: 29927843
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rectangular cuffs may overestimate blood pressure in individuals with large conical arms.
    Palatini P; Benetti E; Fania C; Malipiero G; Saladini F
    J Hypertens; 2012 Mar; 30(3):530-6. PubMed ID: 22278143
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability.
    Palatini P; Asmar R; O'Brien E; Padwal R; Parati G; Sarkis J; Stergiou G;
    J Hypertens; 2020 Jul; 38(7):1244-1250. PubMed ID: 32141969
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Criteria for a suitable reference cuff for validation studies of blood pressure measuring devices in people with arm circumference between 43 and 50 cm.
    Palatini P; Fania C; Benetti E; Saladini F; Battista F; Ermolao A
    Blood Press Monit; 2023 Feb; 28(1):67-72. PubMed ID: 36606482
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Upper limb dimensions in adults presenting for elective surgery - implications for blood pressure measurement.
    Chow C; Ceglowski P; Lehane K; Pelecanos A; Wren K; Eley VA
    BMC Anesthesiol; 2020 Apr; 20(1):76. PubMed ID: 32247309
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences.
    Bonso E; Saladini F; Zanier A; Benetti E; Dorigatti F; Palatini P
    Hypertens Res; 2010 Nov; 33(11):1186-91. PubMed ID: 20686489
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correlation of patient characteristics with arm and finger measurements in Asian parturients: a preliminary study.
    Lim MJ; Tan CW; Tan HS; Sultana R; Eley V; Sng BL
    BMC Anesthesiol; 2020 Aug; 20(1):218. PubMed ID: 32867679
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cuff challenges in blood pressure measurement.
    Palatini P; Asmar R
    J Clin Hypertens (Greenwich); 2018 Jul; 20(7):1100-1103. PubMed ID: 30003699
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the conical cuff and the standard rectangular cuffs.
    Maxwell GF; Pruijt JF; Arntzenius AC
    Int J Epidemiol; 1985 Sep; 14(3):468-72. PubMed ID: 4055213
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients.
    Bur A; Hirschl MM; Herkner H; Oschatz E; Kofler J; Woisetschläger C; Laggner AN
    Crit Care Med; 2000 Feb; 28(2):371-6. PubMed ID: 10708169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arm circumference in adults in Poland as an important factor influencing the accuracy of blood pressure readings.
    Zdrojewski T; Kozicka-Kakol K; Chwojnicki K; Szpakowski P; Konarski R; Wyrzykowski B
    Blood Press Monit; 2005 Apr; 10(2):73-7. PubMed ID: 15812254
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review.
    Irving G; Holden J; Stevens R; McManus RJ
    BMJ Open; 2016 Nov; 6(11):e012429. PubMed ID: 27810973
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Agreement between large and small cuffs in sphygmomanometry: a quantitative assessment.
    Iyriboz Y; Hearon CM; Edwards K
    J Clin Monit; 1994 Mar; 10(2):127-33. PubMed ID: 8207453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. US demographic trends in mid-arm circumference and recommended blood pressure cuffs for children and adolescents: data from the National Health and Nutrition Examination Survey 1988-2004.
    Prineas RJ; Ostchega Y; Carroll M; Dillon C; McDowell M
    Blood Press Monit; 2007 Apr; 12(2):75-80. PubMed ID: 17353649
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Determination of arm circumference for correct measurement of blood pressure. Results of an intervention study].
    Oliveras Puig A; Dalfó-Pibernat A; Jdid Rosàs N; Mayor Isaac E; Pérez-Romero L; Gibert Llorach E; Dalfó-Baqué A
    Hipertens Riesgo Vasc; 2015; 32(1):6-11. PubMed ID: 26179852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative effects of cuff size and tightness of fit on accuracy of blood pressure measurements.
    Banner TE; Gravenstein JS
    J Clin Monit; 1991 Oct; 7(4):281-4. PubMed ID: 1744670
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Oversized patient arms: a problem with blood pressure measurements].
    Meyer F; Meyer T; Klein R
    Z Arztl Fortbild Qualitatssich; 2006; 100(5):389-93. PubMed ID: 16955625
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Blood pressure measurement in preschool children: the Hisayama Study.
    Igarashi H; Fukushige J; Akazawa K; Nose Y; Ueda K
    J Paediatr Child Health; 1997 Dec; 33(6):480-3. PubMed ID: 9484677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.