5. Clinical value of dark-blood late gadolinium enhancement cardiovascular magnetic resonance without additional magnetization preparation. Holtackers RJ; Van De Heyning CM; Nazir MS; Rashid I; Ntalas I; Rahman H; Botnar RM; Chiribiri A J Cardiovasc Magn Reson; 2019 Jul; 21(1):44. PubMed ID: 31352900 [TBL] [Abstract][Full Text] [Related]
6. Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar. Francis R; Kellman P; Kotecha T; Baggiano A; Norrington K; Martinez-Naharro A; Nordin S; Knight DS; Rakhit RD; Lockie T; Hawkins PN; Moon JC; Hausenloy DJ; Xue H; Hansen MS; Fontana M J Cardiovasc Magn Reson; 2017 Nov; 19(1):91. PubMed ID: 29162123 [TBL] [Abstract][Full Text] [Related]
7. Three-dimensional phase-sensitive inversion recovery sequencing in the evaluation of left ventricular myocardial scars in ischemic and non-ischemic cardiomyopathy: comparison to three-dimensional inversion recovery sequencing. Kido T; Kido T; Nakamura M; Kawaguchi N; Nishiyama Y; Ogimoto A; Miyagawa M; Mochizuki T Eur J Radiol; 2014 Dec; 83(12):2159-2166. PubMed ID: 25311877 [TBL] [Abstract][Full Text] [Related]
8. Synthetic multi-contrast late gadolinium enhancement imaging using post-contrast magnetic resonance fingerprinting. Rashid I; Al-Kindi S; Rajagopalan V; Walker J; Rajagopalan S; Seiberlich N; Hamilton JI NMR Biomed; 2024 Jan; 37(1):e5043. PubMed ID: 37740596 [TBL] [Abstract][Full Text] [Related]
9. Three-dimensional High-Resolution Dark-Blood Late Gadolinium Enhancement Imaging for Improved Atrial Scar Evaluation. Si D; Wu Y; Xiao J; Qin X; Guo R; Liu B; Ning Z; Yin J; Gao P; Liu Y; Yang D; Cheng K; Chen T; Cheng Z; Lin X; Fang Q; Herzka DA; Ding H Radiology; 2023 Jun; 307(5):e222032. PubMed ID: 37278633 [TBL] [Abstract][Full Text] [Related]
10. Comparison of 3D phase-sensitive inversion-recovery and 2D inversion-recovery MRI at 3.0 T for the assessment of late gadolinium enhancement in patients with hypertrophic cardiomyopathy. Morita K; Utsunomiya D; Oda S; Komi M; Namimoto T; Hirai T; Hashida M; Takashio S; Yamamuro M; Yamashita Y Acad Radiol; 2013 Jun; 20(6):752-7. PubMed ID: 23473721 [TBL] [Abstract][Full Text] [Related]
11. Assessment of late gadolinium enhancement in nonischemic cardiomyopathy: comparison of a fast Phase-Sensitive Inversion Recovery Sequence (PSIR) and a conventional segmented 2D gradient echo recall (GRE) sequence--preliminary findings. Elgeti T; Abdel-Aty H; Wagner M; Busjahn A; Schulz-Menger J; Kivelitz D; Dietz R; Hamm B Invest Radiol; 2007 Oct; 42(10):671-5. PubMed ID: 17984763 [TBL] [Abstract][Full Text] [Related]
12. Myocardial late gadolinium enhancement using delayed 3D IR-FLASH in the pediatric population: feasibility and diagnostic performance compared to single-shot PSIR-bSSFP. Saprungruang A; Aguet J; Gill N; Tassos VP; Amirabadi A; Seed M; Yoo SJ; Lam CZ J Cardiovasc Magn Reson; 2023 Jan; 25(1):2. PubMed ID: 36683053 [TBL] [Abstract][Full Text] [Related]
13. Clinical evaluation of two dark blood methods of late gadolinium quantification of ischemic scar. Foley JRJ; Broadbent DA; Fent GJ; Garg P; Brown LAE; Chew PG; Dobson LE; Swoboda PP; Plein S; Higgins DM; Greenwood JP J Magn Reson Imaging; 2019 Jul; 50(1):146-152. PubMed ID: 30604492 [TBL] [Abstract][Full Text] [Related]
14. Dark blood late enhancement imaging. Kellman P; Xue H; Olivieri LJ; Cross RR; Grant EK; Fontana M; Ugander M; Moon JC; Hansen MS J Cardiovasc Magn Reson; 2016 Nov; 18(1):77. PubMed ID: 27817748 [TBL] [Abstract][Full Text] [Related]
15. Feasibility of gray-blood late gadolinium enhancement evaluation in young patients with congenital and acquired heart disease. Gonzalez de Alba C; Moghari MH; Browne LP; Friesen RM; Fonseca B; Malone LJ Front Cardiovasc Med; 2023; 10():1269412. PubMed ID: 37915741 [TBL] [Abstract][Full Text] [Related]
17. Novel Magnetic Resonance Late Gadolinium Enhancement With Fixed Short Inversion Time in Ischemic Myocardial Scars. Polacin M; Gastl M; Kapos I; Eberhard M; Weber L; Gotschy A; von Spiczak J; Kozerke S; Alkadhi H; Manka R Invest Radiol; 2020 Jul; 55(7):445-450. PubMed ID: 32459683 [TBL] [Abstract][Full Text] [Related]
18. Improved dark blood late gadolinium enhancement (DB-LGE) imaging using an optimized joint inversion preparation and T Basha TA; Tang MC; Tsao C; Tschabrunn CM; Anter E; Manning WJ; Nezafat R Magn Reson Med; 2018 Jan; 79(1):351-360. PubMed ID: 28382726 [TBL] [Abstract][Full Text] [Related]
19. Histopathological Validation of Dark-Blood Late Gadolinium Enhancement MRI Without Additional Magnetization Preparation. Holtackers RJ; Gommers S; Heckman LIB; Van De Heyning CM; Chiribiri A; Prinzen FW J Magn Reson Imaging; 2022 Jan; 55(1):190-197. PubMed ID: 34169603 [TBL] [Abstract][Full Text] [Related]
20. Wideband black-blood late gadolinium enhancement imaging for improved myocardial scar assessment in patients with cardiac implantable electronic devices. Gut P; Cochet H; Caluori G; El-Hamrani D; Constantin M; Vlachos K; Sridi S; Antiochos P; Schwitter J; Masi A; Sacher F; Jaïs P; Stuber M; Bustin A Magn Reson Med; 2024 Jun; ():. PubMed ID: 38852175 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]