BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 35113538)

  • 1. Accurate Isolation of Circulating Tumor Cells via a Heterovalent DNA Framework Recognition Element-Functionalized Microfluidic Chip.
    Liu Y; Lin Z; Zheng Z; Zhang Y; Shui L
    ACS Sens; 2022 Feb; 7(2):666-673. PubMed ID: 35113538
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bioinspired Engineering of a Multivalent Aptamer-Functionalized Nanointerface to Enhance the Capture and Release of Circulating Tumor Cells.
    Song Y; Shi Y; Huang M; Wang W; Wang Y; Cheng J; Lei Z; Zhu Z; Yang C
    Angew Chem Int Ed Engl; 2019 Feb; 58(8):2236-2240. PubMed ID: 30548959
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A micropillar array-based microfluidic chip for label-free separation of circulating tumor cells: The best micropillar geometry?
    Rahmanian M; Sartipzadeh Hematabad O; Askari E; Shokati F; Bakhshi A; Moghadam S; Olfatbakhsh A; Al Sadat Hashemi E; Khorsand Ahmadi M; Morteza Naghib S; Sinha N; Tel J; Eslami Amirabadi H; den Toonder JMJ; Majidzadeh-A K
    J Adv Res; 2023 May; 47():105-121. PubMed ID: 35964874
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aptamer-cocktail Functionalized Nano-microfluidic Chip for Enhancing Isolation and Characterization of Circulating Cancer Cells.
    Li M; Liu D; Zhang J; Zhang X; Dou X
    Anticancer Res; 2022 Sep; 42(9):4345-4358. PubMed ID: 36039433
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multivalent DNA nanospheres for enhanced capture of cancer cells in microfluidic devices.
    Sheng W; Chen T; Tan W; Fan ZH
    ACS Nano; 2013 Aug; 7(8):7067-76. PubMed ID: 23837646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bait-trap chip for accurate and ultrasensitive capture of living circulating tumor cells.
    Jiang W; Han L; Li G; Yang Y; Shen Q; Fan B; Wang Y; Yu X; Sun Y; He S; Du H; Miao J; Wang Y; Jia L
    Acta Biomater; 2023 May; 162():226-239. PubMed ID: 36940769
    [TBL] [Abstract][Full Text] [Related]  

  • 7. DNA Nanolithography Enables a Highly Ordered Recognition Interface in a Microfluidic Chip for the Efficient Capture and Release of Circulating Tumor Cells.
    Zhang J; Lin B; Wu L; Huang M; Li X; Zhang H; Song J; Wang W; Zhao G; Song Y; Yang C
    Angew Chem Int Ed Engl; 2020 Aug; 59(33):14115-14119. PubMed ID: 32394524
    [TBL] [Abstract][Full Text] [Related]  

  • 8. DNA-Programmed Orientation-Ordered Multivalent Microfluidic Interface for Liquid Biopsy.
    Peng J; Liu Y; Su R; Zeng L; Huo Z; Peng R; Yu X; Zhang H; Yang C; Yang L; Zhu Z
    Anal Chem; 2022 Jun; 94(24):8766-8773. PubMed ID: 35670775
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Conductive Nanofibers-Enhanced Microfluidic Device for the Efficient Capture and Electrical Stimulation-Triggered Rapid Release of Circulating Tumor Cells.
    Huang Y; Li X; Hou J; Luo Z; Yang G; Zhou S
    Biosensors (Basel); 2023 Apr; 13(5):. PubMed ID: 37232858
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A PLGA nanofiber microfluidic device for highly efficient isolation and release of different phenotypic circulating tumor cells based on dual aptamers.
    Wu Z; Pan Y; Wang Z; Ding P; Gao T; Li Q; Hu M; Zhu W; Pei R
    J Mater Chem B; 2021 Mar; 9(9):2212-2220. PubMed ID: 33616137
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid and efficient capturing of circulating tumor cells from breast cancer Patient's whole blood via the antibody functionalized microfluidic (AFM) chip.
    Abdulla A; Zhang Z; Ahmad KZ; Warden AR; Li H; Ding X
    Biosens Bioelectron; 2022 Apr; 201():113965. PubMed ID: 35016111
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficient Isolation and Phenotypic Profiling of Circulating Hepatocellular Carcinoma Cells via a Combinatorial-Antibody-Functionalized Microfluidic Synergetic-Chip.
    Zhu L; Lin H; Wan S; Chen X; Wu L; Zhu Z; Song Y; Hu B; Yang C
    Anal Chem; 2020 Nov; 92(22):15229-15235. PubMed ID: 33124804
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multistage microfluidic cell sorting method and chip based on size and stiffness.
    Li G; Ji Y; Wu Y; Liu Y; Li H; Wang Y; Chi M; Sun H; Zhu H
    Biosens Bioelectron; 2023 Oct; 237():115451. PubMed ID: 37327603
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual-Multivalent-Aptamer-Conjugated Nanoprobes for Superefficient Discerning of Single Circulating Tumor Cells in a Microfluidic Chip with Inductively Coupled Plasma Mass Spectrometry Detection.
    Zhang X; Wei X; Men X; Wu CX; Bai JJ; Li WT; Yang T; Chen ML; Wang JH
    ACS Appl Mater Interfaces; 2021 Sep; 13(36):43668-43675. PubMed ID: 34473482
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous enrichment of circulating tumor cells using a microfluidic lateral flow filtration chip.
    Lee SW; Hyun KA; Kim SI; Kang JY; Jung HI
    J Chromatogr A; 2015 Jan; 1377():100-5. PubMed ID: 25542705
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fluidic Multivalent Membrane Nanointerface Enables Synergetic Enrichment of Circulating Tumor Cells with High Efficiency and Viability.
    Wu L; Ding H; Qu X; Shi X; Yang J; Huang M; Zhang J; Zhang H; Song J; Zhu L; Song Y; Ma Y; Yang C
    J Am Chem Soc; 2020 Mar; 142(10):4800-4806. PubMed ID: 32049531
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Isolation and molecular analysis of circulating tumor cells from lung cancer patients using a microfluidic chip type cell sorter.
    Watanabe M; Kenmotsu H; Ko R; Wakuda K; Ono A; Imai H; Taira T; Naito T; Murakami H; Abe M; Endo M; Nakajima T; Koh Y; Takahashi T
    Cancer Sci; 2018 Aug; 109(8):2539-2548. PubMed ID: 29900633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Engineering Biomimetic Biosensor Using Dual-Targeting Multivalent Aptamer Regulated 3D DNA Walker Enables High-Performance Detection of Heterogeneous Circulating Tumor Cells.
    Jia L; Hu Q; Zhang T; Wang Z; Wu D; Xie X; Wang S
    Small; 2023 Sep; 19(38):e2302542. PubMed ID: 37222122
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous single-cell phenotype analysis of hepatocellular carcinoma CTCs using a SERS-aptamer based microfluidic chip.
    Gao R; Zhan C; Wu C; Lu Y; Cao B; Huang J; Wang F; Yu L
    Lab Chip; 2021 Oct; 21(20):3888-3898. PubMed ID: 34387639
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cascaded filter deterministic lateral displacement microchips for isolation and molecular analysis of circulating tumor cells and fusion cells.
    Liu Z; Huang Y; Liang W; Bai J; Feng H; Fang Z; Tian G; Zhu Y; Zhang H; Wang Y; Liu A; Chen Y
    Lab Chip; 2021 Aug; 21(15):2881-2891. PubMed ID: 34219135
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.