These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 35135942)

  • 21. Comparative analysis of the retention force and deformation of PEEK and PEKK removable partial denture clasps with different thicknesses and undercut depths.
    Lee WF; Chen MS; Peng TY; Huang PC; Nikawa H; Peng PW
    J Prosthet Dent; 2024 Feb; 131(2):291.e1-291.e9. PubMed ID: 38057199
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clasp fabrication using one-process molding by repeated laser sintering and high-speed milling.
    Nakata T; Shimpo H; Ohkubo C
    J Prosthodont Res; 2017 Jul; 61(3):276-282. PubMed ID: 27825561
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device.
    Akiyama H; Sakamoto M; Akama R; Takei J
    BMC Oral Health; 2020 Aug; 20(1):228. PubMed ID: 32819330
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The flexibility of titanium clasps compared with cobalt-chromium clasps.
    Essop AR; Salt SA; Sykes LM; Chandler HD; Becker PJ
    SADJ; 2000 Dec; 55(12):672-7. PubMed ID: 12608241
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of arm design and chemical polishing on retentive force of cast titanium alloy clasps.
    Shimpo H
    J Prosthodont; 2008 Jun; 17(4):300-7. PubMed ID: 18205738
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optimization of the dimension of computer numerical control-milled polyetheretherketone clasps: An in vitro evaluation of accuracy.
    Zhang N; Mao B; Chen S; Chen X; Yan P; Yu H
    J Prosthet Dent; 2022 Nov; ():. PubMed ID: 36357192
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.
    Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B
    Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new design for partial denture circumferential clasp arms.
    Brockhurst PJ
    Aust Dent J; 1996 Oct; 41(5):317-23. PubMed ID: 8961605
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vitro study of optimal removable partial denture clasp design made from novel high-performance polyetherketoneketone.
    Peng PW; Chen MS; Peng TY; Huang PC; Nikawa H; Lee WF
    J Prosthodont Res; 2024 Jul; 68(3):466-473. PubMed ID: 38220161
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Macedo AP; de Torres EM; de Mattos Mda G; Ribeiro RF
    Braz Dent J; 2008; 19(3):209-13. PubMed ID: 18949292
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vitro Assessment of Clasps of Cobalt-Chromium and Nickel-titanium Alloys in Removable Prosthesis.
    Kola MZ; Raghav D; Kumar P; Alqahtani F; Murayshed MS; Bhagat TV
    J Contemp Dent Pract; 2016 Mar; 17(3):253-7. PubMed ID: 27207207
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of 3 kinds of processing techniques on the fitness of metal clasp.
    Yin X; Zhou H; Yan F; Wu X; Wu G; Pang D
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 46(10):1122-1128. PubMed ID: 34911843
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps.
    Xie W; Zheng M; Wang J; Li X
    J Prosthet Dent; 2020 Jan; 123(1):163-172. PubMed ID: 30982620
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fabrication of crown restoration retrofitting to existing clasps using CAD/CAM: fitness accuracy and retentive force.
    Ozawa D; Suzuki Y; Kawamura N; Ohkubo C
    J Prosthodont Res; 2015 Apr; 59(2):136-43. PubMed ID: 25662150
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
    Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K
    Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Internal porosity of cast titanium removable partial dentures: Influence of sprue direction on porosity in circumferential clasps of a clinical framework design.
    Baltag I; Watanabe K; Kusakari H; Miyakawa O
    J Prosthet Dent; 2002 Aug; 88(2):151-8. PubMed ID: 12397242
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Deformation and retentive forces variations of the additively manufactured cobalt-chromium and titanium alloys dental clasps.
    El-Tamimi KM; Bayoumi DA; Alshenaiber R; Aljulayfi I; Ahmed MMZ; El-Sayed ME
    Saudi Dent J; 2024 Jun; 36(6):947-953. PubMed ID: 38883903
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of repetitive insertion/removal cycles and simulated occlusal loads on retention of denture retainers.
    Kato Y; Tasaka A; Kato M; Wadachi J; Takemoto S; Yamashita S
    Dent Mater J; 2021 Sep; 40(5):1277-1283. PubMed ID: 33883331
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of various removable partial denture clasp materials and fabrication procedure for placing clasps on canine and premolar teeth.
    VandenBrink JP; Wolfaardt JF; Faulkner MG
    J Prosthet Dent; 1993 Aug; 70(2):180-8. PubMed ID: 8103801
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Cyclic fatigue test of cobalt-chromium alloy cast clasps].
    Xu MR; Cheng H; Zheng M; Li XR; Wu WQ; Chen D
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Jan; 45(1):36-8. PubMed ID: 20368039
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.